3 Power supply 3.4 Power supply and transformer modules Service Manual SIPLACE X-Series S (from Hxxxx) 01/2021 59 3.4.7 Setting the Voltage on the AC/DC Converters Parts, equipment and tools ● Voltage measuring device Ov…

100%1 / 382
3 Power supply
3.4 Power supply and transformer modules
58 Service Manual SIPLACE X-Series S (from Hxxxx) 01/2021
3.4.6 Replacing the AC/DC Converter
Parts, equipment and tools
Fig.62: Overview of the AC/DC converter
1. PS1: AC-/DC converter DC300/150V
1.3kW 3 phase [03103087‑xx]
300/160 V for gantry 1/4
2. PS2: AC-/DC converter DC300/150V
1.3kW 3 phase [03103087‑xx]
300/160 V for gantry 2/3
3. PS3: AC/DC converter 36V 26.7A
960W 3 phase [03103331‑xx]
→ 42 V for Vision, head, conveyor mo-
tors
4. PS4: AC/DC converter DC24V/40A 3
phase [03102840‑xx]
→ 27 V for FCU
5. PS5: AC/DC converter DC24V/20A
3 phase [03055232‑xx]
→ 24V
Removal
Switch off the machine, disconnect it from the power supply and secure it to prevent
unauthorized reactivation.
1.2 "Preparatory work..." [}16]
DANGER
Checking for absence of voltage!
Before you start working check the power supply for absence of voltage and observe
the waiting times! For more information about this read section 3.4.3
"Checking For
Absence of Voltage" [}49].
When replacing the AC/DC converter (PS5) fitted at the side:
Pull the power supply out of the machine a little.
Unplug all electrical connections from the AC/DC converter. You may want to mark the posi-
tions of these connections to make clear assignment easier later on.
Open the lock under the AC/DC converter. Tilt the AC/DC converter slightly upwards and then
take it up and off.
Installation
Follow the removal instructions in reverse order for installation. Also observe the following instruc-
tions:
Set the AC/DC converter (see 3.4.7 "Setting the Voltage on the AC/DC Converters" [}59]).
3 Power supply
3.4 Power supply and transformer modules
Service Manual SIPLACE X-Series S (from Hxxxx) 01/2021 59
3.4.7 Setting the Voltage on the AC/DC Converters
Parts, equipment and tools
Voltage measuring device
Overview
Fig.63: Overview of the AC/DC converter
1. PS1: AC-/DC converter DC300/150V
1.3kW 3 phase [03103087‑xx]
300/160 V for gantry 1/4
2. PS2: AC-/DC converter DC300/150V
1.3kW 3 phase [03103087‑xx]
300/160 V for gantry 2/3
3. PS3: AC/DC converter 36V 26.7A
960W 3 phase [03103331‑xx]
→ 42 V for Vision, head, conveyor mo-
tors
4. PS4: AC/DC converter DC24V/40A 3
phase [03102840‑xx]
→ 27 V for FCU
5. PS5: AC/DC converter DC24V/20A
3 phase [03055232‑xx]
→ 24V
Setting
Fig.64: Setting the AC-DC converter
Open the protective cap on the setting
screw(1)
.
Use a flat-bladed screwdriver to set the
correct voltage on the AC/DC con-
verter.
Check the voltage with a suitable
voltage measuring device between the
terminals +
and.
3 Power supply
3.4 Power supply and transformer modules
60 Service Manual SIPLACE X-Series S (from Hxxxx) 01/2021
3.4.8 Replacing the main switch
Parts, equipment and tools
Main switch 3 pin 25A type P1-25/V/SVB [03114066-xx]
Overview
Fig.65: Main switch - overview
1. Main switch 3 pin 25A type P1-25/V/
SVB [03114066-xx]
2. Electrical connections (3 each on top
and bottom)
3. Mounting rail
4. Axis extension ZAV-T0 for T0, T1, P1
[03119456‑xx]
Removal
Switch off the machine, disconnect it from the power supply and secure it to prevent
unauthorized reactivation.
1.2 "Preparatory work..." [}16]
DANGER
Checking for absence of voltage!
Before you start working check the power supply for absence of voltage and observe
the waiting times! For more information about this read section 3.4.3
"Checking For
Absence of Voltage" [}49].
Unplug the electrical connections on top and bottom of the main switch. You might like to
mark their positions to make clear assignment easier later on.
Pull the main switch off the mounting rail.
Installation