00198829-01_SM_X-Series-S_Hxxxx_EN - 第63页

3 Power supply 3.4 Power supply and transformer modules Service Manual SIPLACE X-Series S (from Hxxxx) 01/2021 63 3.4.11 Replacing the Distribution and Fusing Assembly Parts, equipment and tools ● Distribution and fusing…

100%1 / 382
3 Power supply
3.4 Power supply and transformer modules
62 Service Manual SIPLACE X-Series S (from Hxxxx) 01/2021
3.4.10 Replacing the main power cable
DANGER
For qualified electricians only - observe the instruction manual!
This task may only be performed by a specially trained electrician.
Parts, equipment and tools
Cable: Mains power supply machine [00335210-xx]
Instruction manual for your machine
Overview
Fig.68: Mains connection cable
1. Mains connection cable
2. Strain relief
3. Electrical connections
Removal/installation
Observe the relevant section of the instruction manual for your machine for removal and in-
stallation work.
DANGER
Checking for absence of voltage!
Before you start working check the power supply for absence of voltage and observe
the waiting times! For more information about this read section 3.4.3
"Checking For
Absence of Voltage" [}49].
3 Power supply
3.4 Power supply and transformer modules
Service Manual SIPLACE X-Series S (from Hxxxx) 01/2021 63
3.4.11 Replacing the Distribution and Fusing Assembly
Parts, equipment and tools
Distribution and fusing board assembly [03118289‑xx]
Overview
Fig.69: Distribution and fusing board assembly
1. Distribution and fusing board assembly
Removal
Switch off the machine, disconnect it from the power supply and secure it to prevent
unauthorized reactivation.
1.2 "Preparatory work..." [}16]
DANGER
Checking for absence of voltage!
Before you start working check the power supply for absence of voltage and observe
the waiting times! For more information about this read section 3.4.3
"Checking For
Absence of Voltage" [}49].
Unplug all electrical connections to the board. You may like to mark their positions, to make
clear assignment easier later on.
3.4.11.1 "Distribution and fusing board assembly" [}64]
Fig.70: Fastening screws
Remove the fastening screws on the
board and the ground conductor.
Remove the board.
Installation
Follow the removal instructions in reverse order for installation.
3 Power supply
3.4 Power supply and transformer modules
64 Service Manual SIPLACE X-Series S (from Hxxxx) 01/2021
3.4.11.1 Distribution and fusing board assembly
Fig.71: Distribution and fusing board assembly [03118289‑xx]
Micro fuse 5x20mmT 6.3A 250V (spare part) [03078843‑xx]
Each machine is supplied with a pack of 10 fuses.
CAUTION
Use only 6.3A fuses!
If 10A fuses are present, replace them by 6.3A fuses.