4 Electrics and control system 4.9 Replacing the I/O control unit 80 Service Manual SIPLACE X-Series S (from Hxxxx) 01/2021 Installation Follow the removal instructions in reverse order for installation. Also observe the…

100%1 / 382
4 Electrics and control system
4.9 Replacing the I/O control unit
Service Manual SIPLACE X-Series S (from Hxxxx) 01/2021 79
Connector
Connector Description
CAN 1 Gantry 1
CAN 2 Gantry 2
CAN 3 Gantry 3
CAN 4 Gantry 4
4.9 Replacing the I/O control unit
Parts, equipment and tools
Fig.90: I/O control unit II [03116049-xx]
I/O control unit II [03116049-xx]
Overview
Fig.91: I/O control unit
The I/O control unit is located between loca-
tion 1 and 2, behind the bottom cover.
Removal
Take a note of the component counter reading at the software user interface.
Switch off the machine, disconnect it from the power supply and secure it to prevent
unauthorized reactivation.
1.2 "Preparatory work..." [}16]
Unplug all press-fit connections. You might like to mark their positions to make clear assign-
ment easier later on.
Pull the I/O control unit out of its mount.
4 Electrics and control system
4.9 Replacing the I/O control unit
80 Service Manual SIPLACE X-Series S (from Hxxxx) 01/2021
Installation
Follow the removal instructions in reverse order for installation. Also observe the following instruc-
tions:
Make sure that the DIP switches are configured correctly (see below).
Check if the component counter of the software still matches the value you have written down.
If this is not the case, contact your SIPLACE service team.
Board description
Fig.92: Overview I/O control unit II [03116049‑01]
Fig.93: Overview of I/O control unit [03052315-xx]
1. Status LEDs
2. X9qb: Power supply
3. X1qb: CAN bus 1
4. X10qb: Connection of other I/O modules
possible
5. Red LED
This signals a RESET.
6. H1: 7 segment display
(flashing = O.K.)
7. DIP switch S1
8. Outputs X3qb to X8qb
 NOTICE!
Downwards compatibility
The I/O control unit II [03116049-xx] is
downwards compatible with I/O control
unit [03052315-xx].
All connections and designations are
identical.
.
4 Electrics and control system
4.9 Replacing the I/O control unit
Service Manual SIPLACE X-Series S (from Hxxxx) 01/2021 81
Fig.94: Overview 03052315-02
Settings on the DIP switch block S1 [03052315‑02] [03116049‑01]
Switch Status Description
S1.1 ON/OFF ON: SX4/DX4, X-Series S
OFF: SX1/SX2, DX1/DX2
S1.2 ON/OFF Ballast resistance
ON: SX1/SX2 from machine no.: Nxxxx
OFF: SX4/DX4; X-Series S, SX1/SX2 up to machine no.: Mxxxx
S1.3 OFF Reserve
S1.4 OFF Reserve
S1.5 OFF Reserve
S1.6 OFF ON: serial bootstrap mode, make sure that S1.7 must be OFF
OFF: Standard mode
S1.7 OFF ON: CAN bootstrap mode, make sure that S1.6 must be OFF
OFF: Standard mode
S1.8 OFF ON: module in the RESET status
OFF: Standard mode