94 Service Manual SIPLACE X-Series S (from Hxxxx) 01/2021
5.9 Replacing the proportional controller (pressure control
valve) (location 4)
Parts
Fig.113: Proportional controller [03152704‑xx] (version2)
Proportional controller Sentronic-LP
[03152704Sxx] (replaces
[03065425‑xx])
 NOTICE!
The proportional controller is supplied
with the latest parameters preset. Sub-
sequent programming is not possible.
.
Adapter plate, top [03136076‑xx]
Adapter plate bottom [03138952‑xx]
In vacuum mode, when only one proportional controller is fitted:
Sealing plate for prop. valve (with O-rings) [03113039-xx]
3x ISO4762-M4x55-A2–70 [03147182‑xx] (contained in [03152704Sxx])
(replaces 3x ISO4762-M4x70-A2-70 [03082432-xx] for the old proportional controller
[03065425‑xx])
Equipment and tools
Isoflex Topas NCA 52, can 1kg [00328369‑xx]
or
Isoflex Topas NCA 52, tube 50 g [00330850‑xx]
Loctite 241 [02101037‑xx]
You might require additional documents:
Assembly instructions "Option Vacuum Pump SIPLACE X-Series S from Hxxxx " [DEEN:
00198599‑xx]
Overview
Fig.114: Overview proportional controller (version 1)
1. to 4.: Location 1 to 4
5.: Proportional controller top and bottom
 NOTICE!
Only one proportional controller is fit-
ted for vacuum pump mode (all
heads).
When converting to compressed air
mode (Twin and CPP), you need to fit
a second proportional controller.
Also read the assembly instructions for
the vacuum pump.
.
5 Pneumatic System
5.9 Replacing the proportional controller (pressure control valve) (location 4)
Service Manual SIPLACE X-Series S (from Hxxxx) 01/2021 95
Fig.115: Overview proportional controller (version1)
Version 1:
1. Sealing adapter plate proportional con-
troller [03083211‑xx]
2. Adapter plate proportional controller
3. Fastening screws for adapter plate
Torque: 2.5 – 3.0Nm
4. Proportional controller
5. Fastening screws for proportional con-
troller
Torque: 2.0 – 2.5Nm
Fig.116: Overview proportional controller (version2)
Version 2:
1. 1x O-ring ID10 X 1.0 - NBR70
[03031296‑xx]
1x O-ring ID20 X 1.0 - NBR70
[03146099‑xx]
1x O-ring ID25 X 1.0 - NBR70
[03146100‑xx]
2. Adapter plate bottom [03138952‑xx]
3. 5x ISO10642-M4x14-A2-70
[03091400‑xx]
Torque: 2.5Nm
Loctite 241
4. 1x Proportional controller Sentronic-LP
[03152704‑xx]
5. 3x ISO4762-M4x55-A2-70
[03147182‑xx]
Torque: 2.0 – 2.5Nm
Loctite 241
5 Pneumatic System
5.9 Replacing the proportional controller (pressure control valve) (location 4)
96 Service Manual SIPLACE X-Series S (from Hxxxx) 01/2021
Fig.117: Proportional controller configurations
Configurations
Depending on the configuration, there will be
one or two proportional controllers fitted.
1. One proportional controller (bottom)
Only one proportional controller is fitted,
if the machine is operated exclusively
with SIPLACE C&P20x in vacuum
mode.
2. Two proportional controllers (top and
bottom)
Two proportional controllers are re-
quired in all other cases (mixed head
mode or compressed air mode).
Removal
Switch off the machine, disconnect it from the power supply and secure it to prevent
unauthorized reactivation.
1.2 "Preparatory work..." [}16]
Switch off the compressed air supply and then disconnect the machine from the compressed
air supply.
5.2 "Disabling the compressed air supply" [}86]
To do this, remove the screws fastening the side cover at location 4 and remove this cover.
5.5 "Dismantling the Lower Side Cover" [}88]
Unplug the electrical connection to the proportional controller.
Remove the screws fastening the proportional controller and then remove the controller.
Installation
Follow the removal instructions in reverse order for installation. Also observe the following instructions:
Observe the instructions in section 5.4 "Sealing the Pneumatic Screwed Connections" [}88].
Fig.118: Overview proportional controller (version2)
Clean the sealing rings(1)and the adap-
ter plate(2)
.
Lightly grease the sealing rings with
Isoflex Topas NCA52 and insert these
again into the adapter plate.
Fit the adapter plate with five fastening
screws(3)
(torque: 2.5Nm, Loc-
tite241).
Fit the proportional controller(4) with
three fastening screws(5)
(torque of
2.0 to 2.5Nm, Loctite241).