NPM-TT2 电路图 - 第57页
FAN3 1 2 3 IN220 G24 P24 Roof Cooling Fan MTKA005517** : Whole Cover(H):NPM-TT2 M - n -G103 9GL1224J1J01 RD YE BK SANYO DENKI -K322 PNF0B3 I/O Board M - n -G104 9GL1224J1J01 RD YE BK SANYO DENKI FAN4 1 2 3 IN221 G24 P24 …

-K321
PNF0B4
n
BN
YE
BK
1G111P
1
2
3
4
P24
G24
IN104
CNAIR
IN033
G24
P24
Main Air Pressure
1
2
3
JST
CNAIR
PAP-03V-S
p p
1
2
3
4
p p p
24V
OUT
N.C.
GND
p
-B1033
DP-002Z
SUNX
PUMP
1
2
3
4
-A02
Power Unit
Vacuum Pump
M
-G201
KHD200-306-G1-KK191
Orion Machinery
R2-5
JST
UG201
FK2-4
JST
VG201
WG201
1
2
3
AMP
PUMP
2-178128-4
4
M
-G111
109-642-16
SANYODENKI
Pump Cooling Fan
GN/YE UL1015 16AWG
G111
489-086-L10
SANYO DENKI
G111E1
R2-4
JST
L21bX3
L31bX3
BK
BK
N610119286AC
MTKC003318AC
BK
GN/YE
RD
WH
STO(A)/TC LF 4E×16AWG
BK/WH
BK
RD/WH
RD
2464C(BPF)VVP AWG#24×2P-B
MOLEX
1G111R
43025-0400
4
3
2
1
MTKC003393**
EeX3
1
2
3
ILK Board #1
JST
B1033
PAP-04V-S
4
3
2
1
-K331
PNF0B4
CN-FANA
IN404
G24
P24
1
2
3
JST
CN-FANAK331
PAP-03V-S
1
2
3
ILK Board #2
MTKC003368AA
BK/WH
BK
RD/WH
RD
2464C(BPF)VVP AWG#22×2P-B
Pump Cooling Fan2
M
-
n
-G105
9GL1224J1J01
RD
YE
BK
Sanyo Denki
AMP
G105R
177899-1
3
2
1
AMP
G105P
177907-1
3
2
1
Panasonic Factory Solutions Co.,Ltd. パナソニック ファクトリーソリューションズ株式会社
Name
Drawing No.
Loc. No.
F4K1020-05A
1
2 3 4 5 6 7 8
A
B
C
D
E
F
1 2 3 4 5 6 7 8
A
B
C
D
E
F
Page. No.
NPM-TT2:Main Body Wiring
(Vacuum Pump, Air Pressure Sensor)
MTKA005506+009AD
P009
2464-1061/ⅡA(PF) LF 2P×24AWG
3

FAN3
1
2
3
IN220
G24
P24
Roof Cooling Fan
MTKA005517** : Whole Cover(H):NPM-TT2
M
-
n
-G103
9GL1224J1J01
RD
YE
BK
SANYO DENKI
-K322
PNF0B3
I/O Board
M
-
n
-G104
9GL1224J1J01
RD
YE
BK
SANYO DENKI
FAN4
1
2
3
IN221
G24
P24
Roof Cooling Fan
AMP
G104R
177899-1
3
2
1
AMP
G103R
177899-1
3
2
1
MTKC003336AB
MTKC003315AB
AMP
FAN3K322
177899-1
3
2
1
AMP
FAN4K322
177899-1
3
2
1
AMP
G104P
177907-1
3
2
1
AMP
G103P
177907-1
3
2
1
2464C(BPF)VVP AWG#22×2P-B
RD
RD/WH
BK
BK/WH
2464C(BPF)VVP AWG#22×2P-B
RD
RD/WH
BK
BK/WH
2464-1061/ⅡA(PF) LF 2P×22AWG
1
2464-1061/ⅡA(PF) LF 2P×22AWG
1
Panasonic Factory Solutions Co.,Ltd. パナソニック ファクトリーソリューションズ株式会社
Name
Drawing No.
Loc. No.
F4K1020-05A
1
2 3 4 5 6 7 8
A
B
C
D
E
F
1 2 3 4 5 6 7 8
A
B
C
D
E
F
Page. No.
NPM-TT2:Main Body Wiring
(Roof Cooling Fan Wiring)
MTKA005506+010AB
P010

11
N0.5-3
JST
12
21
22
11
N0.5-3
JST
12
21
22
A4
B4
A3
AMP
S201R
1-1318119-4
B3
A2
B2
A1
B1
A4
B4
A3
AMP
S202R
1-1318119-4
B3
A2
B2
A1
B1
CNEMGF
1
2
3
4
5
6
7
8
9
10
11
12
13
14
IN017
24GND
IN010
CHECK1
CHECK2
CNEMGR
CHECK3
CHECK4
IN014
24GND
24GND
CHECK1
CHECK2
CHECK3
IN011
24GND
IN015
24GND
CHECK4
14
13
12
11
10
9
8
7
6
5
4
MOLEX
CNEMGF
5557-14R-210
3
2
1
14
13
12
11
10
9
8
7
6
5
4
MOLEX
CNEMGR
5557-14R-210
3
2
1
Front EMG Switch
-S201
XW1E-BV403VR-BC-TK2377
11 12
21 22
31 32
IDEC
AMP
S201P
1376009-1
B1
A1
B2
A2
B3
A3
B4
A4
Note1)
Note1)
Rear EMG Switch
-S202
XW1E-BV403VR-BC-TK2377
11 12
21 22
31 32
IDEC
AMP
S202P
1376009-1
B1
A1
B2
A2
B3
A3
B4
A4
Safety Cover Switch 1(F)
-S301
11 12
21 22
IDEC
HS5D-02RNP
Safety Cover Switch 2(R)
-S302
11 12
21 22
IDEC
HS5D-02RNP
32
31
12
11
N0.5-3.7
JST
32 31
22 21
12 11
-S303
Safety Cover Switch 3
(F Hinge Type)
D4NH-1DBC
OMRON
32
31
12
11
N0.5-3.7
JST
32 31
22 21
12 11
-S304
Safety Cover Switch 4
(R Hinge Type)
D4NH-1DBC
OMRON
Note1) Connector Pin arrangement is not sequential.
-A02
Power Unit
MTKC003339AC
MTKC003303AC
2464C(BPF)VVP AWG#20×3P-B
GN
GN/WH
RD
RD/WH
BK
BK/WH
BK/WH
BK
RD/WH
RD
U-TKVV 2P-AWG20
RD
RD/WH
BK
BK/WH
U-TKVV 2P-AWG20
2464C(BPF)VVP AWG#20×3P-B
U-TKVV 2P-AWG20
U-TKVV 2P-AWG20
GN
GN/WH
RD
RD/WH
BK
BK/WH
BK/WH
BK
RD/WH
RD
RD
RD/WH
BK
BK/WH
1
2
3
4
5
6
7
8
9
10
11
12
13
14
S301
S303
S302
S304
2464-1061/ⅡA(PF) LF 3P×20AWG
2
2464-1061/ⅡA(PF) LF 3P×20AWG
2
2464-1061/ⅡA(PF) LF 2P×20AWG
2
2464-1061/ⅡA(PF) LF 2P×20AWG
2
2464-1061/ⅡA(PF) LF 2P×20AWG
2
2464-1061/ⅡA(PF) LF 2P×20AWG
2
Panasonic Factory Solutions Co.,Ltd. パナソニック ファクトリーソリューションズ株式会社
Name
Drawing No.
Loc. No.
F4K1020-05A
1
2 3 4 5 6 7 8
A
B
C
D
E
F
1 2 3 4 5 6 7 8
A
B
C
D
E
F
Page. No.
NPM-TT2:Main Body Wiring
(Safety SW)
MTKA005506+011AC
P011