LBO für minimale LP-Breite 50mm an D4 - 第33页

LBO 50 mm SIPLACE D4 2 Assembly instructions SOKO Stopper LBO for minimum board size 50 mm SIPLACE D4 11/2007 Edition 33 2 Fig. 2.1 1 - 2 Remove covers of the output area and conveyor : Mount the stopper guida nce at the…

100%1 / 50
2 Assembly instructions SOKO Stopper LBO for minimum board size 50 mm SIPLACE D4 LBO 50 mm SIPLACE D4
11/2007 Edition
32
2.3 Hardware
2.3.1 Installation of stopper unit
2
Please demount the cover of placement area 2 to ease the laying of the cables. Before switching
the machine on, the cover has to be mounted.
Without cover placement area 2 is not secured! 2
2
: Switch off the placement system at the main switch.
: Demount the covers of the output area..
2
Fig. 2.11 - 1 Remove covers of the output area
Loosen screws
LBO 50 mm SIPLACE D4 2 Assembly instructions SOKO Stopper LBO for minimum board size 50 mm SIPLACE D4
11/2007 Edition
33
2
Fig. 2.11 - 2 Remove covers of the output area and conveyor
: Mount the stopper guidance at the left side frame of the output conveyor.
2
Fig. 2.11 - 3 Mounting of stopper guidance
Remove cover of output conveyor
Tighten screws loose
Screws to fix the
guiding shafts
2 Assembly instructions SOKO Stopper LBO for minimum board size 50 mm SIPLACE D4 LBO 50 mm SIPLACE D4
11/2007 Edition
34
: Put the stopper unit between the conveyor side parts and pull both guiding shafts through the
stopper unit and fix it at the left side frame (hexagon sockets).
2
Fig. 2.11 - 4 Mounting of stopper unit
2
Fig. 2.11 - 5 Fixing of stopper (left side)
2
Adjustment gauge