LBO für minimale LP-Breite 50mm an D4 - 第44页
2 Assembly instructions SOKO St opper LBO for minimum board size 50 mm SIPLACE D4 LBO 50 mm SIPLACE D4 11/2007 Edition 44 2.1.5 Adjustment of the sen sor for stopper position "up" : S tart SITEST . : Use the SI…

LBO 50 mm SIPLACE D4 2 Assembly instructions SOKO Stopper LBO for minimum board size 50 mm SIPLACE D4
11/2007 Edition
43
2
Fig. 2.14 - 9 Data sheet sensor
2 Assembly instructions SOKO Stopper LBO for minimum board size 50 mm SIPLACE D4 LBO 50 mm SIPLACE D4
11/2007 Edition
44
2.1.5 Adjustment of the sensor for stopper position "up"
: Start SITEST.
: Use the SITEST conveyor functions to feed a test board to placement position 2, second stop-
per position. The stopper is activated now.
: Fix the sensor at a stopper position where the LED is active.
: Deactivate the stopper with the SITEST function.
Check if the LED is deactivated in the "down" position.
The signal "Stopper up" will be given to the machine control unit and the placement starts.
2

LBO 50 mm SIPLACE D4 2 Assembly instructions SOKO Stopper LBO for minimum board size 50 mm SIPLACE D4
11/2007 Edition
45
2.2 Software
2.2.1 Conveyor Firmware
: Start SITEST.
: Download the SOKO conveyor firmware via the SITEST functions.
2
2
This SOKO firmware only runs with machine software 603.xx and 604.xx. 2
2
2.2.2 SITEST adjustments
: Select in SITEST "conveyor functions" at the Icon bar.
: Select the menu item "options and configuration".
: Select the item "conveyor mode" and the function "change conveyor mode", activate "Long
board option and confirm with "Accept".
: Reboot the placement system.
2
Hex file:
TS510613.HEX
Type:
Application
Machine:
SIPLACE D4
Assembly group:
TSP301
HardwareId:
5
HW variant:
S
SW version:
06.13
SW date:
04.10.2007