5OM-1286-007_w - 第41页
Safety Precautions Safe-30 AJQE-ID No. Alert Labels and Description (16) Description The inside of the recognition light source unit becomes high in temperature. Before replacing the lamp with a new one, set the power …

Safety Precautions
Safe-29
AJQE-ID
No. Alert Labels and Description
(14)
Description
The grounding line (PE) must be connected first to the leading-in section of the
primary power supply
.
Imperfect grounding will cause an electric shock.
(15)
(15-1)
(15-2)
(15-3)
Description
This label indicates that high voltage is applied to the area.
Residual voltages may remain behind for a few minutes in the internal devices of
the machine after power interception.
Before performing maintenance work, wait until the char
ge lamps of the DC power
supply and the servoamplifi
er go "OFF" in 10 minutes or more after the power
breaker is set to "OFF".
0701-006

Safety Precautions
Safe-30
AJQE-ID
No. Alert Labels and Description
(16)
Description
The inside of the recognition light source unit becomes high in temperature.
Before replacing the lamp with a new one, set the power breaker to "OFF" and
leave the unit intact until it cools down sufficiently.
(17)
Description
Be sure to firmly hold the handle to bend and extend. Otherwise, the handle will
fall, causing an injury.
(18)
Description
While attaching the handle slides, be sure to prevent your fingers from getting
jammed.
0701-006

Safety Precautions
Safe-31
AJQE-ID
No. Alert Labels and Description
(20)
Description
Before operating the machine, please read the instruction manual carefully for
correct operations.
An operator’
s error will break down the machine, causing an injury or a serious
accident.
(21)
Description
Do not step on the machine.
The machine may be damaged, causing you to fall down from the machine and get
injured.
(22)
Description
Be sure to attach or detach the feeder carefully with both hands. Otherwise, the
feeder may fall down and break. You may also be given an injury
.
0701-006