SIPLACE D系列Servicemanual - 第107页

Measuring Equipment and T ools SIPLACE Axis Tester (SAT) [03002801-01] Servicemanual (internal version) SIPLACE D Series 107 5 Measuring Equipment and T ools 5.1 SIPLACE Axis T ester (SA T) [03002801-01] 5-1: Axis tester…

100%1 / 118
Service Work
Placement Heads White Balance Process for SIPLACE Digital Vision Camera
106 Servicemanual (internal version) SIPLACE D Series
Can2ToPlane ="4"
Can3ToPlane ="8"
Can4ToPlane ="16"
Can5ToPlane ="32"
FlashDelay ="0"
FinishDelay ="0"
ModusFlash ="0"
TriggerExposure ="20"
MaxExposure ="200" />
</SensorSpecificData>
</Sensorsystem>
Parameter name Value of camera Comments
Measuring Equipment and Tools
SIPLACE Axis Tester (SAT) [03002801-01]
Servicemanual (internal version) SIPLACE D Series
107
5 Measuring Equipment and Tools
5.1 SIPLACE Axis Tester (SAT) [03002801-01]
5-1: Axis tester - view from above
Legend
1. LCD display with 240 x 128 pixels, black-and-white display, with background illumination
The LCD display shows the menus and the recorded trigger, track and position signals. All relevant
parameters, such as
Time basis,
Time measurement values,
Signal levels and
Cursor positions with the corresponding time deviation values
are shown as alphanumerical data in the diagram of the measurement curves.
2. Dynamic function display of BNC socket arrangement on the LCD display
3. Dynamic function display of foil button arrangement on the LCD display
4. Five foil buttons for menu control
5. Green LED for displaying operation
NOTE:
The axis tester is designed for all machines with A363. This function is limited for machines with
A364.
Measuring Equipment and Tools
SIPLACE Axis Tester (SAT) [03002801-01]
108 Servicemanual (internal version) SIPLACE D Series
5-2: Axis tester - view from below
Legend
1. Connection for flat ribbon cable:
At the axis tester end:
– 37 pin Sub-D connector
At the axis control end:
– 37 pin Sub-D connector for the S-20/23/25/F4/F5 and HS-50 machines, with the axis control
units A361 or A362
– 25 pin Sub-D connector for the S-15/F3, G machines and the wafflepack changer, with the axis
control unit A360
An adapter is attached to the flat ribbon cable for connection of the 25 pin axis control. The
operating voltages of +5 V- ±5 % and ±15 V- ±5 % are fed via the 37 pin flat ribbon cable from
the axis control unit to the axis tester.
2. 9 pin Sub-D connector for CAN Bus cable e.g. for connection of CAN Bus controlled boards in the
machine – currently not used (transmission rate 128 kBaud to 1 MBaud, impedance 120 Ohm)
3. 9 pin Sub-D connector for the serial interface cable (V24) needed for software downloads, e.g. for
connection of an external PC (max. transmission rate up to 188 kBaud)
4. Four BNC sockets, connection impedance 50 Ohm. Socket assignment can be programmed. The
following signals can be assigned:
Track signal A or B TTL level, max. 5 V
Zero pulse TTL level tmin = 1 µsec
End position signal TTL level tmin > 10 msec
Trigger TTL level tmin > 10 msec
Count error TTL level, trigger signal from count error sensor of oscilloscope
Vtarget ±10 V, analog signal, Ri = 10 kOhm
Force ±10 V analog signal, Ri = 10 kOhm
VREG (resulting current) ±10 V analog signal, Ri = 10 kOhm
Position deviation ±10 V analog signal; signal generated internally in axis tester.