SIPLACE D系列Servicemanual - 第115页
Measuring Equipment and T ools Scope of Delivery Adjustment Aid for C&P DLM [00327005-01] Servicemanual (internal version) SIPLACE D Series 115 5.10 Adjustment Aid for C&P DLM [00327005-01] Complete set: Art. No.…

Measuring Equipment and Tools
Location Tester Scope of Delivery
114 Servicemanual (internal version) SIPLACE D Series
5.8 Location Tester
5.9 Z End Stopper Star Gauge for C&P6/12 [03019865-01]
Application:
The location tester is used to check the feeder
connections at the communication unit of the
changeover table.
Application:
The gauge is used to set the end stop position
of the C&P head Z axis.

Measuring Equipment and Tools
Scope of Delivery Adjustment Aid for C&P DLM [00327005-01]
Servicemanual (internal version) SIPLACE D Series
115
5.10 Adjustment Aid for C&P DLM [00327005-01]
Complete set: Art. No. 00327005-01
1. Gauge for star [00326164-01]
2. Test probe 1.4 mm [00326160-01]
3. Test probe 1.5 mm [00326161-01]
4. Test probe 1.6 mm [00326162-01]
5. Test probe 1.0 mm [00376656-01]
6. Distance gauge [00325445-01]
Measurement tools Application type
Gauge for star Setting the zero point correction for the star
Test probe 1.4 mm Setting the distance between the DP station incremental encoder and the glass for
the sleeve
Test probe 1.5 mm
Test probe 1.6 mm
Test probe 1.0 mm Setting the distance from the Z axis light barrier down to the sleeve shaft
Distance gauge Setting the distance of the valve plunger to the star

Measuring Equipment and Tools
Calibration Tool [03010565-01] Scope of Delivery
116 Servicemanual (internal version) SIPLACE D Series
5.11 Calibration Tool [03010565-01]
5.12 Calibration Nozzle for Twin Head [03008862-xx]
Application:
The calibration tool [003010565-xx] is used for
calibration of the C&P6/12 placement heads,
P&P and Twin Head (for X series).
Application:
The calibration nozzle is used to calibrate the
D axis of the Twin Head or P&P head.