03217917-01-01E By DEK Technical Reference Manual Vol 1_enPDFA - 第207页
15 BOARD STOP 15.6 ADJUSTMENTS AND SETTINGS TECHNICAL REFERENCE MANUAL Vol 1 E By DEK 04/2019 207 15.6.4.2 External Services ► Select Shut Down . ► Select Continue . ► Switch the mains isolator to OFF . ► Disconnect the …

15 BOARD STOP
15.6 ADJUSTMENTS AND SETTINGS
206 TECHNICAL REFERENCE MANUAL Vol 1 E By DEK 04/2019
15.6.4 Camera to Remote Board Stop - LHS Configuration
WARNING
BOARD CLAMPS. EXTREME CARE MUST BE EXERCISED WHEN WORKING IN
THE TOOLING AREA OF THE MACHINE TO AVOID INJURY. THE FOILS ON THE
FRONT AND REAR BOARD CLAMPS ARE VERY SHARP.
WARNING
COMPRESSED AIR. COMPRESSED AIR SHOULD NEVER IMPINGE UPON THE
BODY. PORTS, PIPES, ETC MUST NEVER BE BLOCKED BY HAND. BEFORE
CONNECTING OR DISCONNECTING ANY PNEUMATIC COMPONENTS, ENSURE
THE COMPRESSED AIR SUPPLY HAS BEEN DISSIPATED AND DISCONNECTED
FROM THE MACHINE.
This procedure details the changes required to convert from using the camera mounted board stop
to the remote board stop mounted on the left hand side of the rising table.
15.6.4.1 Preparation
► Select Open Cover Commands.
► Select Carriage To Rear.
► Select Unload Screen.
► Open the front printhead cover.
► Remove the screen from the machine.
► Close the front printhead cover.
► Press the System button.
► Select Back.
► Select Maintenance.
► Select Machine Setup.
► Select Options.
► Select Remote Board Stop.
► Select Fitted.
► Select Accept.
► Select Back.
► Select Back.
► Select Back.
► Select Setup Product.
► Select Load Product.
► Select the product file to be used with the remote board stop.
NOTE
The selected product file must have a board width of 130mm or greater.
► Select Load.
► Select Back.
► Select Back.

15 BOARD STOP
15.6 ADJUSTMENTS AND SETTINGS
TECHNICAL REFERENCE MANUAL Vol 1 E By DEK 04/2019 207
15.6.4.2 External Services
► Select Shut Down.
► Select Continue.
► Switch the mains isolator to OFF.
► Disconnect the quick release mains air connection at the rear the machine.
► Remove the machine rear cover.
► Remove the left hand side safety cover.
► At the board stop solenoid (16SOL14), on the pneumatic manifold at the rear of the machine:
1. Remove the pipe marked Board Stop from the front port (A) (2).
2. If an in-line flow controller is not already connected to the rear port (B) (1), remove the exist-
ing blanking plug (3) from the rear port (B) (1) and fit the in-line flow controller (5), via the
50mm x 4mm pipe (4) (both supplied with the remote board stop) to the rear port (B) (1). The
in-line flow controller (5) should have a self-seal connector (6) at its open end.
1
2
3
4
5
6
3. Fit the pipe marked Remote/B/Stop Up - LH to the front port (A) (2).
4. Fit the pipe marked Remote/B/Stop Down - LH to the in-line flow controller, self-seal con-
nector (6)fitted to the rear port (B) (1).
► Behind the front cover, mounted on the machine frame:
1. Remove plug BPL6 from socket BSK6.
2. Connect plug BPL6A to socket BSK6.
► Fit the rear cover.

15 BOARD STOP
15.6 ADJUSTMENTS AND SETTINGS
208 TECHNICAL REFERENCE MANUAL Vol 1 E By DEK 04/2019
15.6.4.3 Fitting the Remote Board Stop
► Fit the remote board stop base clamp locating nut (1) into the attachment slot (2) on the left
hand side of the rising table.
1
2
► Attach the base clamp (3) to the locating nut (1), in the correct position in the Y axis for the
product, using a 4mm Allen key and M5 securing screw and washer (4).
4
3
► Mark the centre point, in the X axis, on the front of the product board.
► Place the product board on the rails with the board centre point at the Camera Reference Po-
sition (white dot on front rail).
► Before fitting the remote board stop assembly to the base clamp, ensure that the board stop is
configured for left hand side operation, 15.6.2.1 "LHS Configuration" [}199] refers.
► Lay the remote board stop assembly (5) onto the base clamp (6) so that the board stop is
clear of the board.