03217917-01-01E By DEK Technical Reference Manual Vol 1_enPDFA - 第213页
15 BOARD STOP 15.6 ADJUSTMENTS AND SETTINGS TECHNICAL REFERENCE MANUAL Vol 1 E By DEK 04/2019 213 ► Lay the remote board stop assembly (7) onto the base clamp (5) so that the board stop is clear of the board. 7 5 6 ► Usi…

15 BOARD STOP
15.6 ADJUSTMENTS AND SETTINGS
212 TECHNICAL REFERENCE MANUAL Vol 1 E By DEK 04/2019
15.6.5.3 Fitting the Remote Board Stop
► Fit the remote board stop base clamp locating nut (1) into the attachment slot (2) on the right
hand side of the rising table.
1
2
► Attach the base clamp (4) to the locating nut (1), in the correct position in the Y axis for the
product, using a 4mm Allen key and M5 securing screw and washer (3).
4
3
► Mark the centre point, in the X axis, on the front of the product board.
► Place the product board on the rails with the board centre point at the Camera Reference Po-
sition (white dot on front rail).
► Before fitting the remote board stop assembly to the base clamp, ensure that the board stop is
configured for right hand side operation, 15.6.3 "Setting the Remote Board Stop" [}203]
refers.

15 BOARD STOP
15.6 ADJUSTMENTS AND SETTINGS
TECHNICAL REFERENCE MANUAL Vol 1 E By DEK 04/2019 213
► Lay the remote board stop assembly (7) onto the base clamp (5) so that the board stop is
clear of the board.
7
5
6
► Using the appropriate slots, loosely secure the remote board stop assembly (7) to the base
clamp (5), using the four M5 cap head screws (6).
► Connect plug 8PL05 to socket 8SK05R.
► Connect the pipe marked Remote/B/Stop R1 to the in-line connector on the pipe marked 1 on
the remote board stop.
► Connect the pipe marked Remote/B/Stop R2 to the in-line connector on the pipe marked 2 on
the remote board stop.
► Refit the right hand side safety cover.
► Reconnect the mains air quick release connection to the machine.
► Switch the mains isolator to ON.
► Press the Start button.
► When prompted select Diagnostics.
► When prompted press the System button.
► Carry out 15.6.3 "Setting the Remote Board Stop" [}203].

15 BOARD STOP
15.6 ADJUSTMENTS AND SETTINGS
214 TECHNICAL REFERENCE MANUAL Vol 1 E By DEK 04/2019
15.6.6 Remote Board Stop - LHS to RHS Configuration
WARNING
BOARD CLAMPS. EXTREME CARE MUST BE EXERCISED WHEN WORKING IN
THE TOOLING AREA OF THE MACHINE TO AVOID INJURY. THE FOILS ON THE
FRONT AND REAR BOARD CLAMPS ARE VERY SHARP.
WARNING
COMPRESSED AIR. COMPRESSED AIR SHOULD NEVER IMPINGE UPON THE
BODY. PORTS, PIPES, ETC MUST NEVER BE BLOCKED BY HAND. BEFORE
CONNECTING OR DISCONNECTING ANY PNEUMATIC COMPONENTS, ENSURE
THE COMPRESSED AIR SUPPLY HAS BEEN DISSIPATED AND DISCONNECTED
FROM THE MACHINE.
This procedure details the changes required to convert the machine configuration using the remote
board stop mounted on the left hand side of the rising table to the remote board stop mounted on
the right hand side of the rising table.
15.6.6.1 Preparation
► Select Open Cover Commands.
► Select Carriage To Rear.
► Select Unload Screen.
► Open the front printhead cover.
► Remove the screen from the machine.
► Remove the left and right hand side safety covers.
► Loosen the securing screw (2) from the underside of the base clamp (1), using a 4mm Allen
key.
12
► Slide the remote board stop to the front of the machine, until it abuts the front rail.
► Close the front printhead cover.
► Press the System button.
► Select Back.
► Select Setup Product.
► Select Load Product.
► Select the product file to be used with the remote board stop.
NOTE