15 BOARD STOP 15.6 ADJUSTMENTS AND SETTINGS 218 TECHNICAL REFERENCE MANUAL Vol 1 E By DEK 04/2019 ► Lay the remote board stop assembly onto the base clamp so that the board stop is clear of the board. 1 3 2 ► Using the a…

100%1 / 292
15 BOARD STOP
15.6 ADJUSTMENTS AND SETTINGS
TECHNICAL REFERENCE MANUAL Vol 1 E By DEK 04/2019 217
Fit the base clamp locating nut (5) into the attachment slot (6) on the right hand side of the
rising table.
5
6
Attach the base clamp (3) to the locating nut (1), in the correct position in the Y axis for the
product, using a 4mm Allen key and M5 securing screw and washer (4).
3
4
Mark the centre point, in the X axis, on the front of the product board.
Place the product board on the rails with the board centre point at the Camera Reference Po-
sition (white dot on front rail).
Before fitting the remote board stop assembly (2) to the base clamp (3), ensure that the board
stop is configured for right hand side operation, carry out 15.6.2.2 "RHS Configuration" [}201]
section of this chapter.
15 BOARD STOP
15.6 ADJUSTMENTS AND SETTINGS
218 TECHNICAL REFERENCE MANUAL Vol 1 E By DEK 04/2019
Lay the remote board stop assembly onto the base clamp so that the board stop is clear of the
board.
1
3
2
Using the appropriate slots, loosely secure the remote board stop assembly (2) to the base
clamp (3), using the four M5 cap head screws (1).
Connect plug 8PL05 to socket 8SK05R.
Connect the pipe marked Remote/B/Stop R1 to the in-line connector on the pipe marked 1 on
the remote board stop.
Connect the pipe marked Remote/B/Stop R2 to the in-line connector on the pipe marked 2 on
the remote board stop.
Refit the right and left hand side safety covers.
Reconnect the mains air quick release connection to the machine.
Switch the mains isolator to ON.
Press the Start button.
When prompted select Diagnostics.
When prompted press the System button.
Carry out 15.6.3 "Setting the Remote Board Stop" [}203].
15 BOARD STOP
15.6 ADJUSTMENTS AND SETTINGS
TECHNICAL REFERENCE MANUAL Vol 1 E By DEK 04/2019 219
15.6.7 Remote Board Stop - RHS to LHS Configuration
WARNING
BOARD CLAMPS. EXTREME CARE MUST BE EXERCISED WHEN WORKING IN
THE TOOLING AREA OF THE MACHINE TO AVOID INJURY. THE FOILS ON THE
FRONT AND REAR BOARD CLAMPS ARE VERY SHARP.
WARNING
COMPRESSED AIR. COMPRESSED AIR SHOULD NEVER IMPINGE UPON THE
BODY. PORTS, PIPES, ETC MUST NEVER BE BLOCKED BY HAND. BEFORE
CONNECTING OR DISCONNECTING ANY PNEUMATIC COMPONENTS, ENSURE
THE COMPRESSED AIR SUPPLY HAS BEEN DISSIPATED AND DISCONNECTED
FROM THE MACHINE.
This procedure details the changes required to convert the machine configuration from a right hand
mounted remote board stop to a left hand mounted remote board stop.
15.6.7.1 Preparation
Select Open Cover Commands.
Select Carriage To Rear.
Select Unload Screen.
Open the front printhead cover.
Remove the screen from the machine.
Remove the left and right hand side safety covers.
Loosen the securing screw (2) from the underside of the base clamp (1), using a 4mm Allen
key.
12
Slide the remote board stop to the front of the machine, until it abuts the front rail.
Close the front printhead cover.
Press the System button.
Select Back.
Select Setup Product.
Select Load Product.
Select the product file to be used with the remote board stop.
NOTE
The selected product file must have a board width of 130mm or greater.
Select Load.