CP-7[732-742]-series Mechanical Reference(2.9E) - 第115页

9. Open the front doors. 10. Remove the oil from the theta ( θ ) index unit drain plug. Use a plastic sheet as shown in the diagram below, remove the drain plug and drain the old oil into the collecting bucket. Note: 1. …

100%1 / 251
5. Open the doors at the rear of the machine.
6. Cover the cameras, prism box and surrounding areas with a plastic sheet.
Note: Cover the machine carefully to prevent oil spilling on the machine when draining the
oil cooler.
7. Remove the oil from the nozzle index unit drain plug.
Cover the corrugated cardboard with a plastic sheet, create a slope and drain the
contents of the nozzle index unit into a collecting bucket.
Note: The oil removed from the machine should be discarded in accordance with local
ordinances from handling waste matter.
8. Replace and properly tighten the drain plug once the oil has been fully removed.
C7SM3105
Slope
Drain plug
C7SM3104
Plastic sheet
Part 3 Chapter 2 Lubrication
Edition 2.9 3-2-23 CP-7 series Mechanical Reference
9. Open the front doors.
10. Remove the oil from the theta (θ) index unit drain plug.
Use a plastic sheet as shown in the diagram below, remove the drain plug and
drain the old oil into the collecting bucket.
Note: 1. Carefully arrange the plastic sheet to prevent oil spilling on the machine when
draining the oil cooler.
2. The oil removed from the machine should be discarded in accordance with local
ordinances from handling waste matter.
11. Replace and properly tighten the drain plug once the oil has been fully removed.
C7SM3106
Plastic sheet
Drain plug
Part 3 Chapter 2 Lubrication
Edition 2.9 3-2-24 CP-7 series Mechanical Reference
12. Slowly pour the new lubricating oil into the inlet on the top of the oil cooler.
13. Ensure that the surface of the oil is in the range specified by the level indicator.
Note: Whether the machine is at rest or during operation, the oil level does not normally
change. Immediately after replacing the oil after 3 years or 12,000 hours of
operation, the oil level will drop when operating the machine. Following operation,
add more oil until the level falls within the recommended range.
<CP-732E> <CP-742E><CP-742ME>
C7SM3101
Oil range
Oil cooler
Gauge glass
Level indicator
Cap
Oil inlet
(50)
Part 3 Chapter 2 Lubrication
Edition 2.9 3-2-25 CP-7 series Mechanical Reference