1.13 Mechanical V alve Switching (Station 13) Point The station 13 mechanical valve is used to switch the vacuum off inside the nozzle. This releases the negative pressure in the nozzle, and the nozzle can no longer hold…

100%1 / 251
1.12.3 Clutch Meshing Check Sensor Amp Adjustment
Adjust the sensor amp so that it goes off when the clutches mesh properly and it goes on
when the clutches do not mesh properly and the dog is pushed down.
Remove the cover of the amp and follow the procedures below.
Note: Be careful not to drop the cover inside the machine.
1. Set the setting switch to “D ON”.
2. Set the mode selector switch to “SET”. The digital display will then indicate “1”.
3. With the clutch engagement sensor on (sensor is detecting the hole in the dog),
press the [TUNING] button. The digital display will then indicate “2”.
4. With the clutch engagement sensor off (sensor is not detecting the hole in the dog),
press the [TUNING] button. The digital display will then indicate “9”.
5. Set the mode selector switch to “RUN”.
6. After completing the amplifier setting procedure, verify that the digital display
indicates 0 ~ 1 when the sensor is on, and 8 ~ 9 at all other times.
( 1 )
C7SM4040
SO
DELAY
TUNING
SET D ON
RUN L ON
( 2 )
SO
DELAY
TUNING
SET D ON
RUN L ON
( 3 )
SO
DELAY
TUNING
SET D ON
RUN L ON
( 4 )
SO
DELAY
TUNING
SET D ON
RUN L ON
( 5 )
SO
DELAY
TUNING
SET D ON
RUN L ON
Sensor ON Sensor OFF
Part 4 Chapter 1 Station Adjustments
Edition 2.4 4-1-39 CP-7 series Mechanical Reference
1.13 Mechanical Valve Switching (Station 13)
Point
The station 13 mechanical valve is used to switch the vacuum off inside the nozzle. This
releases the negative pressure in the nozzle, and the nozzle can no longer hold a part.
Verify that parts which fail vision processing are discarded at station 13.
1.13.1 Valve Switching Unit Position Adjustment
This adjustment should be performed on the high valve head after completing adjustments to
the vertical movement of the nozzle during the placement (Refer to 1. 10 “Nozzle Vertical
Movement During Placement” for details). The high valve head can be identified by its
height. The heights of the spool lower surface are measured for all placing heads with spools
lifted, and the highest one is referred to as the high valve head.
Spool
C7SM4055
C7SM4041a
Part 4 Chapter 1 Station Adjustments
Edition 2.4 4-1-40 CP-7 series Mechanical Reference
1. Press the EMERGENCY STOP button to take the 200V down to 100V.
WARNING
Always be sure to cut off the 200V power before carrying
out any work.
Exercise extreme caution when working on the machine if
the cam is not at its origin (0 deg.). Recoil of the cam
axis can endanger the operator.
2. Use an inching operation and move the high valve head to 12 station.
3. Attach the centering jig to the mechanical valve of the high valve head.
Note: Put the 0.2 mm spacer between the fixing bolt and the mechanical valve in order to
avoid any scratch to the mechanical valve.
4. Move the high valve head to station 13.
5. Use the cam handle to rotate the cam to the following cam angles:
CP-732E : 194°
CP-742ME/CP-742E : 190°
Make sure that the pusher is inserted smoothly to the hole at the bottom of the
centering jig. If not, loosen the fixing bolts and adjust the position of the valve
switching unit.
C7SM4067
Centering jig
Pusher
Fixing bolt
Valve switching unit
Z9627DGPJ0110
t = 0.2 mm
Centering jig
Spacer
Bolt
Mechanical valve
Part 4 Chapter 1 Station Adjustments
Edition 2.4 4-1-41 CP-7 series Mechanical Reference