AC Servopack Check List for Troubleshooting
Alarm Alarm Name Status Cause Check Item Remedy
A.30 Regenerative
Error Detected
Occurs at control power ON.
Occurs at main power ON.
Servopack defective.
Wiring to regenerative resistor
defective.
Servopack defective.
Incorrect regenerative resistor
wiring.
Regenerative resistor
disconnected.
Check the wiring to regenerative
resistor.
Servopack defective.
Check that wiring to the
regenerative resistor is proper.
Check the regenerative
resistance value.
Replace the Servopack.
Check the regenerative value
and correct the wiring.
Replace the Servopack.
Manually correct the wiring of the
external regenerative resistor.
Replace the external
regenerative resistor.
A.32 Regenerative
overload
Occurs at control power ON.
Occurs at normal operation.
Servopack defective.
Parameter Pn600 set value is
not correct when a regenerative
resistor is mounted externally.
Servopack defective.
Check that parameter Pn600 set
value is correct.
Servopack defective.
Replace the Servopack.
Set parameter Pn600 correctly.
Replace the Servopack.
NP1MT002E
A.40 Overvoltage Occurs at control power ON.
Occurs at main power ON
or when motor is in operation.
Servopack defective.
Excessive power supply voltage.
Servopack defective.
Check the AC power supply
voltage. (Is there excessive
voltage variation?)
Servopack defective.
Replace the Servopack.
Set the AC power supply voltage
to a value in the normal setting
range.
Replace the Servopack.
A.41 Undervoltage Occurs at control power ON.
Occurs at main power ON
or when motor is in operation.
Servopack defective.
Power supply voltage is
excessively small.
Servopack defective.
Power supply variation is large
and power supply is reduced.
Check the AC power supply
voltage. (Pay attention to
different power supply applied.)
Servopack defective.
Check that a momentary power
failure has not occurred.
Replace the Servopack.
Set the AC power supply voltage
to a value in the normal setting
range.
Replace the Servopack.
Part 5 Chapter 2 Servo System Troubleshooting
Edition 2.6 5-2-6 CP-7 series Mechanical Reference
AC Servopack Check List for Troubleshooting
Alarm Alarm Name Status Cause Check Item Remedy
A.51 Overspeed Occurs at control power ON.
Occurs at main power ON
or when motor is in
operation.
Servopack defective.
Incorrect motor wiring.
Incorrect encoder wiring.
Servopack defective.
Check that the motor rotating
direction is correct (phases U, V
and W wiring).
Servopack defective.
Replace the Servopack.
Manually correct the motor
wiring.
Manually correct the encoder
wiring.
Replace the Servopack.
A.71
A.72
Overload for
Instantaneous
Maximum Load
Overload for
Continuous
Minimum Load
Occurs at control power ON.
Occurs at main power ON
or when motor is in
operation.
Servopack defective.
Incorrect motor wiring.
(imperfect wiring or connection)
Incorrect encoder wiring.
(imperfect wiring or connection)
Servopack defective.
Check that the connnection is
correct and that the motor wiring
does not have an open phase.
Servopack defective.
Excessive load on servo.
Replace the Servopack.
Manually correct the motor
wiring.
Manually correct the encoder
wiring.
Replace the Servopack.
Check for excessive load on
components driven by the servo.
NP1MT003E
A.73 Dynamic Brake
Overload
Servopack defective. Replace the Servopack.
A.74 Overload of
in-rush Current
Limit Resistor
Occurs at control power ON.
Occurs at main circuit
power supply ON/OFF.
Servopack defective.
The allowable frequency of
in-rush current limit resistor at
power ON/OFF is exceeded.
Servopack defective.
Check that the allowable
frequency of in-rush current limit
resistor (5 times/min) is not
exceeded.
Check that the Servopack fan is
operating.
Check that the fan for the control
board is operating.
Check the ambient temperature
of the Servopack exceeds 35 °C.
Excessive load on servo.
Replace the Servopack.
Reduce the main circuit power
supply ON/OFF frequency to
5 times/min.
Replace the Servopack.
A.7A Heat Sink
Overheated
Occurs at main power ON
or when motor is in
operation.
Servopack defective.
Ambient temperature of the
Servopack exceeds 35 °C.
Replace the Servopack.
Set the ambient temperature of
the Servopack to 35 °C or less.
Check for excessive load on
components driven by the servo.
Part 5 Chapter 2 Servo System Troubleshooting
Edition 2.6 5-2-7 CP-7 series Mechanical Reference
AC Servopack Check List for Troubleshooting
Alarm Alarm Name Status Cause Check Item Remedy
A.81 Absolute Encoder
Backup Error
Occurs at power ON.
(Pn002.2 = 0)
When used as absolute
encoder.
Occurs at power ON.
(Pn002.2=1)
Turn ON the power supply to the
absolute encoder for the first
time.
Both PG power supply (+5V)
from the Servopack and the
battery power supply are failed.
Absolute encoder defective.
Servopack defective.
Servopack defective when used
as incremental encoder.
Check that the absolute encoder
has been set up.
Check that the power is supplied
to the encoder side.
Encoder defective at alarm
occurrence even by setting up
the absolute encoder again.
Servopack defective if nothing is
wrong in the above check.
Check that the battery is
connected correctly.
Check that the battery voltage is
not reduced to 2.7 V or less.
Servopack defective if nothing is
wrong in the above check.
Set up the encoder.
Set up the encoder after
restoring the power supply to
the encoder (by replacing the
battery, etc.).
Replace the encoder.
Replace the Servopack.
Replace the Servopack.
NP1MT004E
A.82 Encoder
Checksum Error
Occurs at power ON or
when motor is in
operation.
Encoder defective.
Servopack defective.
Set up the encoder. Replace
the motor if the alarm occurs
frequently.
Replace the Servopack.
A.83 Absolute Encoder
Battery Error
Occurs at power ON.
(Pn002.2=0)
When used as absolute
encoder.
Imperfect connection or
disconnection of battery.
Battery voltage is reduced to the
specified value (2.7 V) or less.
Servopack defective.
Connect the battery properly.
Replace the battery and turn
ON the encoder power supply again.
Replace the Servopack.
Replace the Servopack.
A.84 Encoder Data
Error
Occurs at power ON or
when motor is in
operation.
Sensor in the encoder reads the
data improperly.
Encoder malfunctions.
Servopack defective.
Turn ON the encoder power
supply again.
Replace the motor if the alarm
occurs frequently.
Correct the wiring processing
around the encoder.
Replace the motor if the alarm
occurs frequently.
Replace the Servopack.
Servopack defective when used
as incremental encoder.
Occurs at power ON.
(Pn002.2=1)
Part 5 Chapter 2 Servo System Troubleshooting
Edition 2.6 5-2-8 CP-7 series Mechanical Reference