CP-7[732-742]-series Mechanical Reference(2.9E) - 第231页

1. Leveling the Machine Point The machine should be set in position on leveling sheets or blocks. The appropriate leveling sheets and blocks differ depending on the panel conveyance height, and the use of anti-vibration …

100%1 / 251
Part 6
Setup
1. Leveling the Machine
Point
The machine should be set in position on leveling sheets or blocks. The appropriate
leveling sheets and blocks differ depending on the panel conveyance height, and the use
of anti-vibration pads. Refer to the table below.
H=935H=920
H=920
H=930H=912
H=930H=912
H: Board conveyance height Units (mm)
H=900
Anti-vibration pads
used.
Anti-vibration pads
not used.
32
28
16
12
40
30
22
12
12
12
12
12
H=980H=965H=950
90
75
60
H=980H=965H=950 H=962
48
59
75
59
12
12
12
12
C7SM5007
H=935
40
Table01a
Board conveyance
height
Anti-vibration pads
not used.
Anti-vibration pads
used.
Leveling sheet / block
900
Units (mm)
912
920
930
935
950
962
965
980
900
912
920
930
935
950
962
965
980
12
22
30
40
40
60
75
90
24 *
28 *
40 *
44 *
60 *
71 *
71 *
87 *
DCAB0370
DCAB0380
BB43880
GGA8060
GGA8060
GGA8030
GGA8040
BB42950
DCAB0390
GXA2071
DCAB0400
WAB0601
GXA2121
DCAB0410
DCAB0410
DCAB0420
Leveling sheet
HeightDrawing No. Name
Leveling sheet
Leveling sheet
Leveling sheet
Leveling sheet
Leveling sheet
Leveling sheet
Leveling sheet
Leveling sheet
Leveling sheet
Leveling block
Leveling block
Leveling block
Leveling block
Leveling block
Leveling block
* : Includes height of anti-vibration pads (12mm).
Part 6 Chapter 1 Leveling the Machine
Edition 2.3 6-1-1 CP-7-series Mechanical Reference
Procedure
1. Position the leveling sheets or the leveling blocks as shown in the figure below.
2. Set spirit levels on a base surface of the machine (laterally and vertically).
3. Use the leveling bolts to adjust the height.
4. After verifying that the panel conveyance height and the leveling accuracy are
correct, tighten the lock nuts on the leveling bolts. Changes can be made by
tightening the lock nuts, although the levelness should always be checked again
after adjustments have been made.
Note: If the lock nuts are not tightened sufficiently, vibration may result in a drop in
placement accuracy.
125
125
(mm)
C7SM5001-2
538696778
CP-742ME
518
125
125538696778518
150
150
549 965 100
100
593 921 100
100
C7SM5001-1
( mm )
965 472472 125125
100 1432 100
CP-732E
Part 6 Chapter 1 Leveling the Machine
Edition 2.3 6-1-2 CP-7-series Mechanical Reference