00195011-01 - 第31页
Installation Manual, Station Software Version 408.01 Edition 03/2006 4.1.4 Result log The installation program records a detailed l og of which software packages and drivers have been installed. This information is saved…

Installation Manual Station Software Version 408.01
Final screen
The following dialog box appears at the end of the installation:
Fig. 4-18: Final dialog of the SIPLACE installation
→ Select the option No, I will restart my computer later.
→ Click the Finish button.
→ In the Start menu, click Shut Down, and select Shut Down from the dropdown list followed by
the OK button.
→ Switch the machine off when the station computer has shut down.
→ Switch the machine back on again.
Caution:
The machine must always be switched off after installation or after modifiying the configuration.
When the machine is switched back on again it reconfigures the software.
30 of 104

Installation Manual, Station Software Version 408.01 Edition 03/2006
4.1.4 Result log
The installation program records a detailed log of which software packages and drivers have been
installed. This information is saved in the file c:\windows\instlog.txt. You can view this file with any
text editor.
The information in the file is not deleted. New information is added at the end of the file.
Caution:
Under no circumstances should you make changes to the file. It contains important information
for the service engineers.
31 of 104

Installation Manual Station Software Version 408.01
4.2 Machine files
Machine-related configuration, measurement and parameter data is stored in *.MA files.
Note:
All machine data must be of revision level 50 (version 408.01). Current machine data mu
s
not be replaced by revision levels of an earlier version, either completely or partially, e.g.
revision level 40 (version 407.01).
Machine files:
Description File
Axis data
Axis option data ACHS_OPT.MA
Axis measurement data ACHS_VER.MA
Axis data ACHS.MA
Axis operation data ACHS_STD.MA
Component removal module setup BEBAND_1.MA
Component removal module setup BEBAND_2.MA
Surf tape feeder data DCA.MA
Operation data for dip module DIPFLUX.MA
Fine calibration offset FK_OFF.MA
Flux dispenser operation data FLUX.MA
Camera setup KAMSTEU.MA
Machine configuration KONFIG.MA
Force steps for head axis KRAFT.MA
Critical ways KRIWEGE.MA
Control data of mapping MAPPSTEU.MA
Machine type definition MATYP.MA
Switchable machine options OPTIONEN.MA
Options reference run REF_LAUF.MA
Parameters of nozzle splitting SCANPAR.MA
Sensor system SST.MA
Board transport TRANSP.MA
Vacuum data of z axis VAK_Z.MA
Vacuum check file VAKUUM.MA
32 of 104