00195011-01 - 第8页
Installation Manual Station Software Version 408.01 3 Prerequisites 3.1 Sof tware component s 3.1.1 Station computer The station computer uses the follo wing operating system configuration: - Microsoft Windows XP Profess…

Installation Manual, Station Software Version 408.01 Edition 03/2006
2.2 Languages
Station computer user interface:
The standard package contains German and English versions. Other languages contained in the
languages package are optional and available under item number 00378605-xx.
The following table indicates which languages are available for station software:
S23 F5HM CS CF
Sprache
French x x x x
Italian x x x x
Polish x x
Portuguese (Brazil) x x
Russian x x
Spanish (Mexico) x x x x
Czech x x
Hungarian x x
Chinese (simplified) x x
Chinese (traditional) x x
Korean x x
Japanese x x
SITEST user interface:
German and English are included on the software CD.
7 of 104

Installation Manual Station Software Version 408.01
3 Prerequisites
3.1 Software components
3.1.1 Station computer
The station computer uses the following operating system configuration:
- Microsoft Windows XP Professional including Service Pack 2
Attention:
Please make sure that only the Siemens XP Professional Service Pack 2 is installed. The
modified Siemens XP Professional Service Pack 2 is based on Mircrosoft Windows XP Service
Pack 2. Please make sure that never the Mircrosoft XP Professional Service Pack 2 is
installed.
No software or hardware products may be installed on the computer which are not compatible
with Windows XP SP2 (for details, refer to the relevant information from the vendor and to the
Microsoft website
http://support.microsoft.com/default.aspx?kbid=884130).
For details on the SIPLACE products, contact your SIPLACE representative.
3.1.2 Machine components
The following versions of other machine components are required for the station software to function
correctly:
Machine controller version SIPLACE Pro version
Station computer version
408.01 408.01 3.2
Caution:
The functional statuses of the station computer software and the machine controller software
must be compatible.
8 of 104

Installation Manual, Station Software Version 408.01 Edition 03/2006
3.1.3 Minimum requirement for embedded software for SIPLACE machines CS,
CF, S23, F5 HM
Subsystem CF CS S23 F5 HM BIOS File name Application 1 File name
Main axes X X X X 2.07 A0100207.bhx 4.03 A0110403.bhx
Revolver head functions
(not modular)
X X 1.01 K0300101.hex 1.07 K0310107.hex
Revolver head functions X X X X 1.04
K0400104.hex
5.01
K0410501.hex
( modular)
Component table (V24) X X X X 3.02 3.02 Bios.hex 5.02 Tisch.hex
X axis gantry X X 2.07 A0100207.bhx 4.03 A0110403.bhx
Y axis gantry X X 2.07 A0100207.bhx 4.03 A0110403.bhx
Z axis IC head X X 2.07 A0100207.bhx 4.03 A0110403.bhx
DP axis IC head X X 2.07 A0100207.bhx 4.03 A0110403.bhx
Head board RVC head X X 1.04 K0400104.hex 6.09 K0410609.hex
Wafflepack Changer X X - 1.6
WPC lifting axis X X - 3.10
WPC feed axis X X - 3.10
Vision system X X X X - 2321M
Meaning of Symbols:
same download version – no changes
new or modified download version
Attention:
During the job requirement the error message „Communication with table failed“ appears on
tables with a BIOS version <3.01.
Update the EPROM to the currrent BIOS version to eliminate this error.
9 of 104