00196497-07_SM_SXDX12_en - 第113页
Service Work Conveyor 3.4.18 Replacing the X Ax is Axial Fan [03056479-xx] Gantries Service Manual SIPLACE SX1/SX2/DX1/DX2 FS02 113 3.4.18 3 . 4 . 1 8 R e p la c in g t h e X A x is A x ia l F a n [ 0 3 0 5 6 4 7 9 - x x…

Service Work Conveyor
Gantries 3.4.17 Replacing the Y Trailing Cable [03075584-xx]
112 Service Manual SIPLACE SX1/SX2/DX1/DX2 FS02
► Unplug all pneumatic connections to the gantry.
► Unplug all electrical connections from the trailing cable to the X and Y trailing cable interface. (See
also "3.4.4 Replacing the Gantry InterfaceX [03065078‑xx]" [➙88] and "3.4.5 Replacing the Gantry
InterfaceY [03065335‑xx]" [ ➙ 90])
► Unplug all pneumatic connections to the valve block.
► Unplug the electrical connections to the trailing cable interface. (See also "3.4.11 Replacing the Trail-
ing Cable Interface [03064127-xx]" [ ➙ 97])
► Loosen the two screws fastening the trailing cable chain to the gantry. These screws (hexagonal
bolts [03023606-xx]) must be resealed with Loctite 241 when fitted again.
► Loosen the front screw fastening the cover plate.
► Loosen the rear screw fastening the cover plate. There is a slot here. You can now push the cover
plate and lift it off the screw.
► Loosen the two screws fastening the trailing cable chain to the cover plate. These screws (hexagonal
bolts [03023606-xx]) must be resealed with Loctite 241 when fitted again.
► Remove the trailing cable from the machine.
Installation
Adhesive Tape for Gantry Interface
► Follow the removal instructions in reverse order for installation. Also observe the following instruc-
tions:
CAUTION!
During assembly, make sure that the connection rail con-
tacts are insulated with adhesive tape (1) in the direction
of the aluminum holder (2). Do not use conductive tape,
recommendation [03000372-xx] "PTFE glass fiber mate-
rial, self-adhesive, width 20mm" for insulating the con-
tacts.
CAUTION
Installation instructions
► Fix the screws fastening the trailing cable chain to the gantry and to the cover with Loctite
241.

Service Work Conveyor
3.4.18 Replacing the X Axis Axial Fan [03056479-xx] Gantries
Service Manual SIPLACE SX1/SX2/DX1/DX2 FS02 113
3.4.18
3.4.18 Replacing the X Axis Axial Fan [03056479-xx]
Replacing the X Axis Axial Fan [03056479-xx]
Parts, equipment and tools
▪ Fan X/Y motor [03085456-xx]
▪ Locking varnish Loctite 241 [02101037-xx]
Overview
Removal
► Switch off the machine, disconnect it from the power supply and secure it to prevent unauthorized
reactivation. Observe the instructions in section "1.2 Preparatory Work..." [ ➙ 13].
► Dismantle the head adapter HCU. (See "3.4.20 Replacing the Head Adapter for the HCU and MHCU/
HCU" [ ➙ 115])
► Disconnect the fan from the power supply.
► Loosen the 4 screws fastening the fan and remove the fan.
Installation
► Follow the removal instructions in reverse order for installation. Also observe the following instruc-
tions:
1. Installation point for X axis axial fan
CAUTION
Installation instructions
► Secure the fastening screws with Loctite 241.
► Replace any cable ties which you have removed.

Service Work Conveyor
Gantries 3.4.19 Replacing the Y Axis Axial Fan [03056479-xx]
114 Service Manual SIPLACE SX1/SX2/DX1/DX2 FS02
3.4.19
3.4.19 Replacing the Y Axis Axial Fan [03056479-xx]
Replacing the Y Axis Axial Fan [03056479-xx]
Parts, equipment and tools
▪ Fan X/Y motor [03085456-xx]
▪ Locking varnish Loctite 241 [02101037-xx]
Overview
Removal
► Switch off the machine, disconnect it from the power supply and secure it to prevent unauthorized
reactivation. Observe the instructions in section "1.2 Preparatory Work..." [ ➙ 13].
► Loosen the connection cable of the fan. Depending on the gantry side, this is either fitted on the sen-
sor module Y or on the sensor interface. You may want to mark the position, to make clear assign-
ment easier later on.
► Loosen the 4 screws fastening the fan and remove the fan.
Installation
► Follow the removal instructions in reverse order for installation. Also observe the following instruc-
tions:
1. Axial fan Y axis on gantry
2. Sensor interface (on the underside of the gantry)
3. Sensor module Y
CAUTION
Do not pull on the cable!
► When disconnecting the cables from the sensor module Y, do not pull on the cable but only
on the black plastic connector. If you pull on the cable, this could damage the sensor mod-
ule.
CAUTION
Installation instructions
► Secure the fastening screws with Loctite 241.
► Replace any cable ties which you have removed.