00196497-07_SM_SXDX12_en - 第182页

Service Work Conveyor Conveyor 3.6.9 Changing Fixed Side Left/Right (EC Only) 182 Service Manual SIPLACE SX1/SX2/DX1/DX2 FS02 Single conveyor: fixed side right (1) I nput side (2) Output side (3) Connecting plate (ad jus…

100%1 / 334
Service Work Conveyor
3.6.9 Changing Fixed Side Left/Right (EC Only) Conveyor
Service Manual SIPLACE SX1/SX2/DX1/DX2 FS02 181
3.6.9
3.6.9 Changing Fixed Side Left/Right (EC Only)
Changing Fixed Side Left/Right (EC Only)
Parts, equipment and tools
Setting gauge for ultrasonic sensors [03076989-xx]
Programming cable for PXS240 sensor [03073330-xx]
Dowel pin (supplied with conveyor) [03064582-xx]
Overview
Single conveyor: flexible side left
NOTICE
Minimum conveyor width at conveyor with FS02
After conversion to "fixed side left", the minimum conveyor width on the conveyor with FS02 is
100 mm.
(1) Output side (2) Input side
(3) Side flange 2, fixed (output side) (4) Side flange 1, fixed (input side)
(5) Side flange on the flexible conveyor side
(output side)
(6) Side flange on the flexible conveyor side
(input side)
T Transport direction
Service Work Conveyor
Conveyor 3.6.9 Changing Fixed Side Left/Right (EC Only)
182 Service Manual SIPLACE SX1/SX2/DX1/DX2 FS02
Single conveyor: fixed side right
(1) Input side (2) Output side
(3) Connecting plate (adjustment unit for the
flexible side – input side)
(4) Connecting plate (adjustment unit for the
flexible side – output side)
(5) Side flange, fixed (input side) (6) Side flange, fixed (output side)
T Transport direction
Diagrams above: fixed conveyor side
Diagrams below: flexible conveyor side
1. Fastening screw
2. Side flange 2 (2x on the flexible conveyor side)
3. Flexible conveyor side wall
4. Fastening screw
5. Side flange 1 and 2 (on the fixed conveyor side)
6. Fastening screw
7. Fastening screw
8. Carriage (for the flexible conveyor side)
9. Connecting plate (adjustment unit for the flexible
side)
10. Fastening screw
Service Work Conveyor
3.6.9 Changing Fixed Side Left/Right (EC Only) Conveyor
Service Manual SIPLACE SX1/SX2/DX1/DX2 FS02 183
Conversion
Preparation:
Use the software to move the conveyor side into the position which allows you best access to the
conveyor side for the work to be performed.
Switch off the machine, disconnect it from the power supply and secure it to prevent unauthorized
reactivation. Observe the instructions in section "1.2 Preparatory Work..." [ ➙ 13].
Pull the sensor rail off the guidance pins and place it in the conveyor.
Push the carriage (8) under the two conveyor sides.
Rotate the "side flange 2" by 180° and then screw the side flange back onto the carriage. Make sure
that the "side flange 2" (2) is fitted parallel on the carriage (8). Check their parallelism with an H scale.
This may not protrude anywhere.
Fit the "side flanges 2" (2) from the outer side, onto the new flexible conveyor side.
Fit the "side flanges fixed 1 and 2" (5) from the outer side, onto the new fixed conveyor side.
Fix the "side flange fixed 1 and 2" (2) with the dowel pin to the conveyor base.
Set the fixed side to the correct position.
(See "4.6.3.1 Setting the Fixed Conveyor Side on Single Conveyors" [ 280])
Refitting the brackets:
Mark the installation points of the four brackets (2)
and (5), to make clear assignment easier later on.
Loosen the screws (4) fastening the two "side flanges
fixed 1 and 2" (5) on the fixed side.
Loosen the screws (6) fastening the two "side flanges
fixed 1 and 2" (5) on the conveyor base.
Move the "side flanges fixed 1 and 2" (5) from the in-
put to the output area of the new fixed side.
Loosen the screws (1) fastening the two "side flanges
2" (2) on the flexible side
(3).
Disconnect the flexible side from the "side flanges 2"
(2).
Loosen the screws (7) (2x four) fastening the two
"side flanges 2" on the carriage (8).
NOTICE
During refitting, the input and output sides are exchanged (left with right).