Settings 4.3.1 Fuses Electrical and Control Settings Service Manual SIPLACE SX1/SX2/DX1/DX2 FS02 255 4.3 4 . 3 E le c t r ic a l a n d C o n t r o l S e t t in g s Electrical and Control Settings 4.3.1 4 . 3 . 1 F u s e …

100%1 / 334
Settings
Settings on the Basic Machine 4.2.1 Setting the Machine Covers
254 Service Manual SIPLACE SX1/SX2/DX1/DX2 FS02
4.2.1.8
4.2.1.8 Setting the Cover Rollers
Setting the Cover Rollers
Cover rollers (example of SX2 shown)
Set the cover roller by using the grub screw, so that it is inserted by at least 75% into the guidance,
along its whole length. Lock the roller with a setscrew DIN915-M8x16 [00304354-xx] or DIN-EN-
ISO4026-M8x16-A2-21H [03025582-xx].
Place shims between the roller and cover for greater stability.
NOTICE
Missing O-rings
Replace the following missing O-rings on the roller: O-ring 8.5x1.6 [03078577-xx]
NOTICE
Maintenance
There are O-rings on the roller. These need to be checked every 6 months and replaced when
necessary. If the roller or bottom stop is already damaged, this will also need to be replaced.
Settings
4.3.1 Fuses Electrical and Control Settings
Service Manual SIPLACE SX1/SX2/DX1/DX2 FS02 255
4.3
4.3 Electrical and Control Settings
Electrical and Control Settings
4.3.1
4.3.1 Fuses
Fuses
For more information about this, read section "5.1.4 Fuse Connection Board" [ ➙ 309].
4.3.2
4.3.2 Setting the Voltage on the AC/DC Converters
Setting the Voltage on the AC/DC Converters
Parts, Equipment and Tools
Voltage measuring device
Overview
The AC/DC converters are located at the following positions:
PS1: in sector 3 on the power supply switching unit (25 V)
AC/DC converter DC24V/20A 3 phase [03055232-xx]
PS2: in sector 3 on the power supply switching unit (42 V)
AC/DC converter DC36-42V/13.3A 3 phase [03076588-xx]
PS3: in sector 2 (26,8 V)
AC/DC converter DC24V/20A 3 phase [03055232-xx]
Setting
Setting the AC/DC converter
Open the protective cap on the setting screw (1).
Rotate with a slotted screwdriver until the AC/DC
converter provides the correct voltage.
Use a suitable voltage measuring device to check the
voltage between the + and terminals.
Settings
Electrical and Control Settings 4.3.3 CAN I/O Module
256 Service Manual SIPLACE SX1/SX2/DX1/DX2 FS02
4.3.3
4.3.3 CAN I/O Module
CAN I/O Module
Up to machine nos.: Mxxx
For I/O module [03052315-xx]