Settings Nozzle Changer Setting 4.5.3 Jumpers on the Nozzle Change r 272 Service Manual SIPLACE SX1/SX2/DX1/DX2 FS02 4.5.3 4 . 5 . 3 J u m p e r s o n t h e N o z z le C h a n g e r Jumpers on the Nozzle Changer Overview…

Settings
4.5.1 Setting the Nozzle Changer Height (DLM, C&P20, CPP, TH) Nozzle Changer Setting
Service Manual SIPLACE SX1/SX2/DX1/DX2 FS02 271
4.5
4.5 Nozzle Changer Setting
Nozzle Changer Setting
4.5.1
4.5.1 Setting the Nozzle Changer Height (DLM, C&P20, CPP, TH)
Setting the Nozzle Changer Height (DLM, C&P20, CPP, TH)
Parts, equipment and tools
▪ NC shim plate [03021079-xx]
▪ NC support plate [03021044-xx]
▪ Screws DIN 965-M4 x 10-4.8 [00095312-xx]
Setting
4.5.2
4.5.2 Setting the Height of the Nozzle Reject Station (DLM, C&P20, CPP)
Setting the Height of the Nozzle Reject Station (DLM, C&P20, CPP)
Parts, equipment and tools
▪ Shim plates for nozzle reject device [03039514-xx]
Setting
► The distance (1) between the contact surface of the
reject unit and the guide rail of the gantry needs to be
199.8 +/-0.2 mm.
You may need to use shim plates to adjust this.
► The distance (1) between the contact surface of the
nozzle reject station and the guide rail of the gantry
needs to be 189 +0.1/-0.3 mm.
You may need to use shim plates to adjust this.

Settings
Nozzle Changer Setting 4.5.3 Jumpers on the Nozzle Changer
272 Service Manual SIPLACE SX1/SX2/DX1/DX2 FS02
4.5.3
4.5.3 Jumpers on the Nozzle Changer
Jumpers on the Nozzle Changer
Overview
Preparation
1. Jumper X10
The jumper X10 needs to be set at the following nozzle
changers:
▪ Nozzle changer basic structure CPx/all assembly -
short [03103649-xx]
▪ Nozzle changer basic structure CPx/all assembly -
long [03103514-xx]
NOTICE
Before installation
Due to the design, this setting must be performed before installation in the machine.
► If the new nozzle changer is being fitted as a spare part in a machine with I/O module con-
trol, you will need to reconnect the jumper to pin 1-2.
To check whether the machine has I/O module control,
proceed as follows:
► Switch over to the operator level Service.
► Select the button.
► Select the button Embedded Software.
► Select the button Update Subsystem.
► If I/O module control is present, you will see the entry
Nozzle Changer at I/O Module.

Settings
4.5.3 Jumpers on the Nozzle Changer Nozzle Changer Setting
Service Manual SIPLACE SX1/SX2/DX1/DX2 FS02 273
Setting
► Set the correct value on the jumper for your head type, software and control method.
Nozzle Changer CP20P - Jumper X10
Jumper X10
See also
5.5.2 Nozzle Changer Main Board C&P20P [03107652-xx] [ ➙ 330]
Head SW <= 706.x SW >= 707.x
I/O controller XFCU I/O controller XFCU
CPx, DLM 1-2 1-2 1-2 2-3
C&P20 P --- --- --- 2-3 (factory set-
tings)