00196497-07_SM_SXDX12_en - 第306页
Description of the Circuit Boards Electrics and Control 5.1.3 I/O control unit [0 3116049-xx] 306 Service Manual SIPLACE SX1/SX2/DX1/DX2 FS02 03052315-02 LEDs [03052315-02] [03116049-01] LEDs Outputs X8qb [03052315- 02] …

Description of the Circuit Boards
5.1.3 I/O control unit [03116049-xx] Electrics and Control
Service Manual SIPLACE SX1/SX2/DX1/DX2 FS02 305
LEDs, Displays
03052315-02
7-segment display H1 [03052315-02]
Display Status Description
Dot Flashes Circuit board OK
0 ON Firmware OK
1 ON CAN telegram cannot be transmitted
2 ON FW error: overflow in the CAN bus receiver buffer
3 ON CAN bus controller in the status ERROR PASSIVE
4 ON CAN bus controller in the status BUS OFF
5 ON Processor board received a message instead of a com-
mand
6 ON PowerFail signal active
F ON Other error
Any ON Hardware problem
A ON When initializing: BIOS mode changes to application mode
b ON When booting: head processor remains in BIOS mode

Description of the Circuit Boards
Electrics and Control 5.1.3 I/O control unit [03116049-xx]
306 Service Manual SIPLACE SX1/SX2/DX1/DX2 FS02
03052315-02
LEDs [03052315-02] [03116049-01]
LEDs Outputs X8qb [03052315-02] [03116049-01]
LEDs Outputs X7qb [03052315-02] [03116049-01]
LED Color Status Signal name Description
H3 RD ON _RSTOUT Signals a RESET
LED Color Status Signal name Description
H48 GN Flashes DO15 No PCB in conveyor lane 2
H49 GN ON DO14 Failure on location 2
H2 GN ON DO13 Failure on location 1
H51 GN Flashes DO12 No PCB in conveyor lane 1
H44 GN ON DO11 Control speaker 2
H45 GN ON DO10 Control speaker 1
H46 GN - DO9 Not used
H47 ON - DO8 24V interlock hood 1 and 2 (option)
LED Color Status Signal name Description
H40 GN - DO7 Not used
H41 GN ON DO6 Vacuum pump switched on (option)
H42 GN OFF DO5 Opens the main valve
H43 GN - DO4 Not used
H36 GN ON DO3 Switches the shut-off valve, COT insert

Description of the Circuit Boards
5.1.3 I/O control unit [03116049-xx] Electrics and Control
Service Manual SIPLACE SX1/SX2/DX1/DX2 FS02 307
LEDs Inputs X6qb [03052315-02] [03116049-01]
LEDs Inputs X5qb [03052315-02] [03116049-01]
LEDs Inputs X4qb [03052315-02] [03116049-01]
H37 GN - DO2 Not used
H38 GN ON DO1 Software_Ctrl On
Software ready, safety circuit closed
H39 GN - DO0 Not used
LED Color Status Signal name Description
H34 GN - DI 31 Not used
H35 GN - DI30 Not used
H32 GN - DI29 Not used
H33 GN - DI28 Not used
H30 GN - DI27 Not used
H31 GN - DI26 Not used
H28 GN - DI25 Not used
H29 GN - DI24 Not used
LED Color Status Signal name Description
H26 GN - DI23 Not used
H27 GN - DI22 Not used
H24 GN - DI21 Not used
H25 GN ON DI20 EMERGENCY STOP button released on location 2
H22 GN - DI19 Not used
H23 GN ON DI18 CO trolley docked in on location 2
H20 GN ON DI17 Hood closed on location 2
H21 GN - DI16 Not used
LED Color Status Signal name Description
H18 GN ON DI15 Operating pressure reached
H19 GN - DI14 Not used
H16 GN - DI13 Not used
H17 GN ON DI12 EMERGENCY STOP button released on location 1
H14 GN ON DI11 PowerEnable signal from power supply
H15 GN ON DI10 CO trolley docked in on location 1
H12 GN ON DI9 Hood closed on location 1
H13 GN ON DI8 EMERGENCY STOP button released on WPC
LED Color Status Signal name Description