Description of the Circuit Boards
Electrics and Control 5.1.5 Inrush Current Limitation Board Transformer (A1) [03066830-xx]
310 Service Manual SIPLACE SX1/SX2/DX1/DX2 FS02
5.1.5
5.1.5 Inrush Current Limitation Board Transformer (A1) [03066830-xx]
Inrush Current Limitation Board Transformer (A1) [03066830-xx]
03066830-01
Jumper J1:
HF/X series: jumper to ON
SX4: jumper to OFF
SX1/SX2: The jumper is not queried here. The
jumper setting is therefore irrelevant.
Description of the Circuit Boards
5.2.1 Head Interface C700B [03055072-xx] Gantry
Service Manual SIPLACE SX1/SX2/DX1/DX2 FS02 311
5.2
5.2 Gantry
Gantry
5.2.1
5.2.1 Head Interface C700B [03055072-xx]
Head Interface C700B [03055072-xx]
The "Module Head Interface C700B" [03055072-xx] contains the "PCB Head Interface C700B"
[03055071-xx] and the "Module Powercube" [03055514-xx] amongst others.
03055071-05
1. Assembly position of the Module / Powercube [03055514-xx]
LED [03055071-05]
NOTICE
C&P20 P
The following additional conditions must be fulfilled for operating a C&P20 P:
The head interface must have function state [03055072-05] at least (with head interface
board [03055071-07]).
The MODULE / Powercube must have at least function state [03055514-02].
You find a complete list of the prerequisites in section Replacing the C&P20 P Head.
LED Color Status Signal name Description
H2 RD ON POWERFAI
L_BASE_3V
POWERFAIL signal enabled by power supply
PF - lights up if the PowerFail signal is triggered by the
power supply
H3 RD ON EMERGEN
CY_STOP_
3V
Cover open, emergency STOP enabled
E_STOP - Emergency-Stop shines when cover open and
emergency STOP activated
H4 GN ON P3V3 3.3 V voltage OK
FPGA - monitors the microcontroller on the basic adapter
board (should always be green)
Description of the Circuit Boards
Gantry 5.2.1 Head Interface C700B [03055072-xx]
312 Service Manual SIPLACE SX1/SX2/DX1/DX2 FS02
DIP switch block S1 [03055071-05]
Terminals (selection)
Switch S1
Switch Status Signal name Description
S1.1 OFF DCDC_OFF Standard mode, ON: RESET only possible when
not all the voltages are present
S1.2 OFF FAN Standard mode: automatic operation, when the
hood is open, the fans of the X/Y motors are
switched off
ON: fans are always switched on
Gantry 1 Gantry 2
S1.3 ON/OFF GANTRY_ID1 OFF ON
S1.4 ON/OFF GANTRY_ID0 OFF OFF
Terminal Description
X3, X4 Gantry interface
X5 Vision board (CAN_H/L)
X6 Base adapter board
X10 SPS option
X14 Incremental encoder (new)
X15 Incremental encoder (old)
Switch Description
1P0 Gantry coding:
gantry 1: P1=OFF, P2=OFF – gantry 2: P1=OFF, P2=ON
2P1
3FANFan: OFF (standard) automatic mode – ON: fan always on
4 DC/DC DC/DC converter:
OFF: standard
ON: Reset - Reset is only possible, if not all the voltages are present (PowerFail
LEDs on the basic adapter board).