00196497-07_SM_SXDX12_en - 第319页

Description of the Circuit Boards 5.2.5 Base adapter Gantry Service Manual SIPLACE SX1/SX2/DX1/DX2 FS02 319 5.2.5.2 5 . 2 . 5 . 2 B a s e a d a p t e r T W I N [ 0 3 0 5 5 5 1 7 - x x ] Base adapter TWIN [03055517-xx] 03…

100%1 / 334
Description of the Circuit Boards
Gantry 5.2.5 Base adapter
318 Service Manual SIPLACE SX1/SX2/DX1/DX2 FS02
7-segment display V12 [03055516-03]
Switch S1 []03055516-03
Dip switch S2 [03055516-03]
Display Status Description
Decimal point Flashes HCU1 OK
Switch Status Function
S1 40 V Intermediate circuit voltage for Z axis/C&P20 head
150 V Intermediate circuit voltage for Z axis/CPP head
Switch Status Signal name Description
S2.1 OFF HCU_CM_FPGA_IO_0 Gantry ID not used
S2.2 OFF HCU_CM_FPGA_IO_1 Gantry ID not used
S2.3 OFF RESET_HCU1 RESET HCU
S2.4 OFF COM_BOOT_HCU BOOTSTRAP function for HCU
Description of the Circuit Boards
5.2.5 Base adapter Gantry
Service Manual SIPLACE SX1/SX2/DX1/DX2 FS02 319
5.2.5.2
5.2.5.2 Base adapter TWIN [03055517-xx]
Base adapter TWIN [03055517-xx]
03055517-03
LED [03055517-03]
7-segment display V12 (HCU1), V2 (HCU2) [03055517-03]
Dip switch S1 [03055517-03]
LED Color Status Signal name Description
H1 GN ON Programming plug for the HCU1 is connected
H2 GN ON HCU2 programming connector connected
H3 RD ON FPGA_TEST_6 1.5VDC PowerFail
H4 RD ON FPGA_TEST_2 3.3VDC PowerFail
H5 RD ON FPGA_TEST_4 5VDC PowerFail
H6 RD ON FPGA_TEST_1 15VDC PowerFail
H7 RD ON FPGA_TEST_3 DP PowerFail, not used
H8 RD ON FPGA_TEST_5 24VDC PowerFail
H9 RD ON POWERFAIL_LOCAL PowerFail board:
ON, when 1.5VDC, 3.3VDC, 5VDC and 15VDC
are outside the permissible tolerance
H10 RD ON +V_DISP_HCU1 HCU1 error
H11 GN ON +V_DISP_HCU1 HCU1 OK
H12 RD ON +V_DISP_HCU2 HCU2 error
H13 GN ON +V_DISP_HCU2 HCU2 OK
Display Status Description
Decimal point Flashes HCU1 OK
Switch Status Signal name Description
S1.1 - - Not used
S1.2 OFF RESET_HCU2 ON: Reset HCU2
Description of the Circuit Boards
Gantry 5.2.6 Vision hotlink adapter [03050555-xx]
320 Service Manual SIPLACE SX1/SX2/DX1/DX2 FS02
Dip switch S2 [03055517-03]
5.2.6
5.2.6 Vision hotlink adapter [03050555-xx]
Vision hotlink adapter [03050555-xx]
03050555-01
LED [03050555-01]
Switch Status Signal name Description
S2.1 OFF HCU_CM_FPGA_IO_0 „S0“ (gantry coding), not used
S2.2 OFF HCU_CM_FPGA_IO_1 „S1“ (gantry coding), not used
S2.3 OFF RESET_HCU1 ON: Reset HCU!
S2.4 OFF COM_BOOT_HCU ON: set to boot mode
LED Color Status Description
D1 GN ON +12VDC
D8 RD ON CLKUSR error
D9 GN ON +5 VDC
D10 GN OFF CRC_ERR