Service Work Conveyor Electrical System 3.2.2 Measuring Voltages at the Power Supply Unit 40 Service Manual SIPLACE SX1/SX2/DX1/DX2 FS02 Preparation ► Reconnec t the ma chine to the power sup ply. ► Switch the placement …

100%1 / 334
Service Work Conveyor
3.2.1 Electrical Checks Electrical System
Service Manual SIPLACE SX1/SX2/DX1/DX2 FS02 39
3.2
3.2 Electrical System
Electrical System
DANGER - Checking the power supply for absence of voltage
See also
3.4.15 Replacing the MGCU/GCU [ ➙ 104]
5 Description of the Circuit Boards [ ➙ 299]
3.2.1
3.2.1 Electrical Checks
Electrical Checks
For any electrical checks, please read the appropriate circuit diagram folder of your machine:
SIPLACE SX1/SX2/DX1/DX2 detailed circuit diagrams [00196475-xx] (German/English)
See also
5.1.4 Fuse Connection Board [ ➙ 309]
3.2.2
3.2.2 Measuring Voltages at the Power Supply Unit
Measuring Voltages at the Power Supply Unit
DANGER - Voltages (wit hout SMPS)
Tools and Equipment Required
Digital voltmeter, class 1, 5
Test cable with test probes or terminals
Circuit diagram folder for your machine
DANGER
Checking for absence of voltage!
Before you start working, check the power supply for absence of voltage and observe the
waiting times!
DANGER
Voltages
There is a risk of dangerous touch voltages and short circuits occurring in power supplies which
have been made accessible and are connected for measurement purposes or bridge circuit
control.
Nonobservance of these safety instructions may cause injury to personnel and damage to the
machine!
Measurements may only be performed by specially trained service technicians, with appropri-
ate qualifications and expertise.
Observe the instructions in section Safety Instructions for the Power Supply (Without
SMPS).
Service Work Conveyor
Electrical System 3.2.2 Measuring Voltages at the Power Supply Unit
40 Service Manual SIPLACE SX1/SX2/DX1/DX2 FS02
Preparation
Reconnect the machine to the power supply.
Switch the placement machine on again at the main switch and start it up.
Performing measurements
Measure the required voltages.
CAUTION
Take care not to damage the supply lines!
Make sure that the main power cable and supply cables in the machine are not trapped and
that the insulation is not damaged.
End all placement operations on the machine.
Switch the machine off at the main switch (2).
Disconnect the machine from the main power supply.
Open the lock (1) on the power supply cover (3).
Pull the power supply out towards the front.
DANGER
Touch voltages
There may be dangerous touch voltages in the vicinity of the open power supply!
NOTICE
Voltages
Please refer to the relevant circuit diagram for your machine for details of the various voltages.
Service Work Conveyor
3.2.3 Checking the Input Voltage at the Inrush Current Limitation Board (A1) Electrical System
Service Manual SIPLACE SX1/SX2/DX1/DX2 FS02 41
3.2.3
3.2.3 Checking the Input Voltage at the Inrush Current Limitation Board (A1)
Checking the Input Voltage at the Inrush Current Limitation Board (A1)
DANGER - Voltages (wit hout SMPS)
Checking/setting
Remove the mesh cover on the boards. To do this, loosen the four screws on the side of the cover.
Check the jumper arrangement and correct if necessary.
Take note of the position of jumper J1 (see "5.1.5 Inrush Current Limitation Board Transformer (A1)
[03066830-xx]" [ 310]).
Fit the protective grid back into place.
See also
1.1.3 Safety Instructions for the Power Supply [ ➙ 10]
DANGER
Voltages
There is a risk of dangerous touch voltages and short circuits occurring in power supplies which
have been made accessible and are connected for measurement purposes or bridge circuit
control.
Nonobservance of these safety instructions may cause injury to personnel and damage to the
machine!
Measurements may only be performed by specially trained service technicians, with appropri-
ate qualifications and expertise.
Observe the instructions in section Safety Instructions for the Power Supply (Without
SMPS).
1. Board A1 for the inrush current limitation board of the
transformer
X1, X2, X3: plug-in jumpers to configure the inrush cur-
rent limitation
The inrush current limitation board must be set to 400 V,
irrespective of the supply voltage. This is performed with
the help of plug-in jumpers on the inrush current limitation
board (1).
Check the jumper assignments and correct these,
where necessary.