00196497-07_SM_SXDX12_en - 第53页

Service Work Conveyor 3.2.13 Replacing the Motor Protection Relea se Block (PKZ2) Elect rical System Service Manual SIPLACE SX1/SX2/DX1/DX2 FS02 53 Removal ► Switch off the machine, disconnec t it from the po wer supply …

100%1 / 334
Service Work Conveyor
Electrical System 3.2.13 Replacing the Motor Protection Release Block (PKZ2)
52 Service Manual SIPLACE SX1/SX2/DX1/DX2 FS02
3.2.13
3.2.13 Replacing the Motor Protection Release Block (PKZ2)
Replacing the Motor Protection Release Block (PKZ2)
Parts, Equipment and Tools
If you have supply voltages of 3x208 V~ and 3x230 V~, you will need to use the motor protection release
block ZM-32-PKZ2 [00342496-xx].
Motor protection release block ZM-16-PKZ2 [00342495-xx] (default)
Motor protection release block ZM-32-PKZ2 [00342496-xx] (US version)
Overview
NOTICE
Old version [00342494-xx]
This version of the protective motor switch has been discontinued and may need to be replaced
with the new version "protective motor switch PKE32/XTU-32 assembly 3-pin" [03098183-xx].
Read also section "3.2.14 Replacing the Motor Circuit Breaker PKE32/XTU-32 [03098183-
xx]" [ 55] and the technical information "Product discontinuation of "Protective motor
switch PKZ2 basic machine, 3-pin" [00342494-xx]" [TI2015-03D02] [EN: TI2015-03E02].
Protective motor switch
1. Locking tab
2. Rotary switch
3. Trigger threshold for overcurrent (yellow setting disk)
4. Protective flap
5. Trigger threshold for short-circuit current (red setting
disk)
6. Motor protection release block
Service Work Conveyor
3.2.13 Replacing the Motor Protection Release Block (PKZ2) Electrical System
Service Manual SIPLACE SX1/SX2/DX1/DX2 FS02 53
Removal
Switch off the machine, disconnect it from the power supply and secure it to prevent unauthorized
reactivation. Observe the instructions in section "1.2 Preparatory Work..." [ ➙ 13].
Checking the Power Supply for Absence of Voltage
Before you start working, check the power supply for absence of voltage and observe the waiting
times!
Turn the switch (1) anticlockwise to the position "0"
Open the protective flap (1).
Use a screwdriver to push the yellow locking tab (1)
upwards.
Pull the motor protection release block (1) out.
Service Work Conveyor
Electrical System 3.2.13 Replacing the Motor Protection Release Block (PKZ2)
54 Service Manual SIPLACE SX1/SX2/DX1/DX2 FS02
Installation
Motor protection release block settings
Motor release
block
Yellow setting disk for
overcurent trigger
threshold
Red setting disk for
short-circuit current
trigger threshold
X-Series/SX4/DX4 for 3x208V~ +/-5%
(US version)
ZM-32-PKZ2 24 A 375 A
X-Series/SX4/DX4 for 3x400V~ +/-5% ZM-16-PKZ2 16 A 200 A
SX1/SX2/DX1/DX2 at 3x208V~ +/-5% ZM-16-PKZ2 16 A 130 A
SX1/SX2/DX1/DX2 at 3x400V~ +/-5% ZM-16-PKZ2 10 A 130 A
Check the trigger threshold for overcurrent (yellow
setting disk (1)).
Check the trigger threshold for short-circuit current
(red setting disk (2)).
Insert the motor protection release block.
Push the yellow locking tab downwards.
Close the gray protective flap.
Turn the rotary switch clockwise as far as the stop.