00196497-07_SM_SXDX12_en - 第60页

Service Work Conveyor Electrical System 3.2.14 Replacing the Motor Circuit Breaker PKE 32/XTU-32 [03098183-xx] 60 Service Manual SIPLACE SX1/SX2/DX1/DX2 FS02 3.2.14.1 3 . 2 . 1 4 . 1 A d ju s t m e n t o f t h e M o t o …

100%1 / 334
Service Work Conveyor
3.2.14 Replacing the Motor Circuit Breaker PKE32/XTU-32 [03098183-xx] Electrical System
Service Manual SIPLACE SX1/SX2/DX1/DX2 FS02 59
Follow the removal instructions in reverse order for installation. Also observe the following instruc-
tions:
Fitting the switch bracket
Fit the switch bracket (1) with the grub screw (2).
Tighten the screw with a torque of 0.6 Nm.
CAUTION
Installation instructions
Set the nominal current and overcurrent (see below).
Service Work Conveyor
Electrical System 3.2.14 Replacing the Motor Circuit Breaker PKE32/XTU-32 [03098183-xx]
60 Service Manual SIPLACE SX1/SX2/DX1/DX2 FS02
3.2.14.1
3.2.14.1 Adjustment of the Motor Protection Switch PKE32 [03098183-xx]
Adjustment of the Motor Protection Switch PKE32 [03098183-xx]
Adjusting the settings of the protective motor switch PKE32
At the marked position (green arrow), open the cover above the adjustment screws. Use a size 1
screwdriver for this.
Set the overcurrent class (2) to the value 5. This applies to all machines.
Set the rated current (1) to the following values:
NOTICE
Supply of the vacuum pump with machine current
The following adjustment values are valid for all machines.
Exception: For machines with vacuum pumps that are supplied via the machine power supply
other values may apply.
1 Rated current 2 Overcurrent class
Without vacuum pump 240/400V 50Hz network: rated current: 8.0 A
110/208V 60Hz USA network: rated current: 13.5 A
With one vacuum pump
(SX1/SX2, DX1/DX2, SX4/DX4, X-Series
S)
240/400V (50Hz) network: rated current: 8.0 A
110/208V (60Hz ) USA network: rated current: 13.5 A
With two vacuum pumps
(SX4/DX4, X-Series S)
240/400V (50Hz) network: rated current: 13.5 A
110/208V (60Hz ) USA network: rated current: 17.2 A
Service Work Conveyor
3.2.15 Replacing the Shunt Release A-PKZ0 24VDC [03102397-xx] Electrical System
Service Manual SIPLACE SX1/SX2/DX1/DX2 FS02 61
3.2.15
3.2.15 Replacing the Shunt Release A-PKZ0 24VDC [03102397-xx]
Replacing the Shunt Release A-PKZ0 24VDC [03102397-xx]
Parts, Equipment and Tools
Shunt release A-PKZ0 24VDC [03102397-xx]
Overview
Removal
Switch off the machine, disconnect it from the power supply and secure it to prevent unauthorized
reactivation. Observe the instructions in section "1.2 Preparatory Work..." [ ➙ 13].
Checking the Power Supply for Absence of Voltage
Before you start working, check the power supply for absence of voltage and observe the waiting
times!
Dismantle the motor protections switch (see "3.2.14 Replacing the Motor Circuit Breaker PKE32/
XTU-32 [03098183-xx]" [ 55]).
Lift the shunt release off the protective motor switch.
Installation
Installation is performed by following the above instructions in the reverse order.
NOTICE
Not for US network 3x208 V
The shunt release is not present in the 2x208 V US network.
The shunt release (1) is located on the side of the protec-
tive motor switch.