Service Work Conveyor Gantries 3.4.7 Replacing the Head Interface [0 3055072-xx] 92 Service Manual SIPLACE SX1/SX2/DX1/DX2 FS02 3.4.7 3 . 4 . 7 R e p la c in g t h e H e a d I n t e r f a c e [ 0 3 0 5 5 0 7 2 - x x ] Re…

100%1 / 334
Service Work Conveyor
3.4.6 Replacing the Sensor Interface [03060962-xx] Gantries
Service Manual SIPLACE SX1/SX2/DX1/DX2 FS02 91
3.4.6
3.4.6 Replacing the Sensor Interface [03060962-xx]
Replacing the Sensor Interface [03060962-xx]
Parts, Equipment and Tools
Sensor interface [03060962-xx]
Overview
Removal
Switch off the machine, disconnect it from the power supply and secure it to prevent unauthorized
reactivation. Observe the instructions in section "1.2 Preparatory Work..." [ ➙ 13].
Loosen the two screws fastening the cover plate.
Unplug the electrical connections to the sensor interface. You may want to mark their positions, to
make clear assignment easier later on.
Loosen the screws fastening the sensor interface mount.
Loosen the screws fastening the sensor interface to the mount and remove the sensor interface.
Installation
Follow the removal instructions in reverse order for installation.
The sensor interface is on the underside of the gantry,
behind a cover.
1. Screws fastening the cover above the sensor inter-
face
(the cover has already been removed in the diagram).
2. Sensor interface
Service Work Conveyor
Gantries 3.4.7 Replacing the Head Interface [03055072-xx]
92 Service Manual SIPLACE SX1/SX2/DX1/DX2 FS02
3.4.7
3.4.7 Replacing the Head Interface [03055072-xx]
Replacing the Head Interface [03055072-xx]
Parts, Equipment and Tools
MODULE/head interface C700B [03055072-xx]
Overview
Removal
Switch off the machine, disconnect it from the power supply and secure it to prevent unauthorized
reactivation. Observe the instructions in section What To Do Before Starting Servicing Work....
If there is a cover above the boards, dismantle it.
Unplug all connectors and cable ties on the head interface. You may want to mark their positions, to
make clear assignment or replacement easier later on.
Dismantle the sensor module. To do this, undo the four fastening screws and the cable holder. Some
versions may include a protective sheet, which is also held with these screws.
Remove the six screws and the cable holder on the head interface.
Carefully pull the head interface towards the front. Make sure that the connectors on the head adapt-
er are not damaged.
Installation
Follow the removal instructions in reverse order for installation. Also observe the following instruc-
tions:
NOTICE
C&P20 P
If you are converting to a C&P20 P, one prerequisite is function state -05 or higher for the head
interface.
You find a complete list of the prerequisites in section Replacing the C&P20 P Head.
Boards on the Gantry
1. Vision board spread spectrum
2. Head adapter (here the version for the TwinHead with
two HCUs)
3. HCU
4. Head interface
5. Sensor module
CAUTION
Installation instructions
Check the setting of the DIP switch.
(See "5.2.1 Head Interface C700B [03055072-xx]" [ ➙ 311])
Service Work Conveyor
3.4.8 Replacing the Power Cube Module on the Head Interface Gantries
Service Manual SIPLACE SX1/SX2/DX1/DX2 FS02 93
3.4.8
3.4.8 Replacing the Power Cube Module on the Head Interface
Replacing the Power Cube Module on the Head Interface
Overview
Removal
SXDX12V1V2
Remove the head interface. Also read section "3.4.7 Replacing the Head Interface [03055072-xx]"
[➙92].
Remove the four screws fastening the power cube and carefully lift off the power cube from the head
interface.
Installation
Installation is performed by following the above instructions in the reverse order. Also observe the
following instructions:
See also
3.4.7 Replacing the Head Interface [03055072-xx] [ ➙ 92]
NOTICE
C&P20 P
The following additional conditions must be fulfilled for operating a C&P20 P:
The MODULE / Powercube must have at least function state [03055514-02].
You find a complete list of the prerequisites in section Replacing the C&P20 P Head.
MODULE / Powercube [03055514-xx]
NOTICE
Installation instructions
Make sure that the power cube is positioned correctly.