00192662-01.pdf - 第204页

5 Single Functions User Manual SIPLACE F5/F5 HM 5.2 Single functions, Gantry Software version SR.407.x x 01/2001 US E dition 204 5.2.8 "Nozzle c hanger configur ation revol ver head" screen for 12-nozzl e C&amp…

100%1 / 596
User Manual SIPLACE F5/F5 HM 5 Single Functions
Software version SR.407.xx 01/2001 US Edition 5.2 Single functions, Gantry
203
During setup change, it may be necessary to change to a different type of nozzle in individual mag-
azines. To do this, the table shows for each nozzle holder the current nozzle configuration (Actual)
and the nozzle configuration required by the new setup (Preset).
When a nozzle is changed from the "Actual nozzle type" to the "Preset nozzle type", this operation
must be confirmed. This can either be done for all the nozzle holders in a magazine ("Confirm
magaz." function) or separately for each nozzle holder ("Confirm one nozzle" function). 5
NOTE
The magazines must always be completely filled. 5
Confirm magaz. 5
This function confirms that all nozzle holders of one magazine have been filled with nozzles of a
new type. 5
Å In the table, select any entry for a nozzle holder of the magazine in which the nozzles are to
be replaced. The line is now highlighted in light blue.
Å Click the Lock. op./close button.
Å Replace all the nozzles by nozzles of the type entered in the "Preset" column.
Å Click the Lock. op./close button again.
Å Click the Confirm one nozzle button to confirm that the nozzles in the selected nozzle holder
have been replaced. The change of is now confirmed. In the table, the arrow ( <== ) is no longer
displayed next to the entry for this nozzle holder.
5
5 Single Functions User Manual SIPLACE F5/F5 HM
5.2 Single functions, Gantry Software version SR.407.xx 01/2001 US Edition
204
5.2.8 "Nozzle changer configuration revolver head" screen for 12-nozzle C&P
head
5
Å In the current screen for the single function for Gantry, click the symbol .
NOTE
The nozzle changer must be installed and configured in the machine options. When calling
this screen the nozzles on the placement head are returned to the nozzle changer. 5
The user interface is switched to the "Nozzle changer configuration revolver head" screen (see
Fig. 5.2 - 12
). 5
5
Fig. 5.2 - 12 "Nozzle changer configuration revolver head" screen (12-nozzle Collect&Place head)
User Manual SIPLACE F5/F5 HM 5 Single Functions
Software version SR.407.xx 01/2001 US Edition 5.2 Single functions, Gantry
205
5.2.8.1 General comments
In the "Nozzle changer configuration revolver head" screen there are functions which allow you to
adjust and confirm the nozzle configuration for the individual magazines in the nozzle changer.
Click on the appropriate button to carry out the required function.
The nozzle changer configuration is displayed in the table in the display.
5
Conditions for changing the set-up of the nozzle changer
Remember the following points when changing the set-up: 5
The magazines may only be filled when all nozzles on the Collect&Place head have been re-
turned to their magazines.
Magazines may only contain nozzles of one type.
The maximum number of nozzles per magazine is 12.
The maximum number of magazines on a nozzle changer is 7.
The magazines must be filled outside the machine and must only ever be changed in their en-
tirety.
To remove and load nozzles you must open the lock. Once you have finished, you must then
close the lock again.
Meaning of the entries in the table in the display
Magazine
Number of the magazine
Number
Number of nozzles in the magazine
Actual
Type of nozzles currently in the magazine
Preset
If the type of nozzle currently in the magazine is not the same as shown in this column, then it
is to be changed
To change
An arrow ( <== ) in this column indicates that the nozzle type currently in the magazine ("Ac-
tual" column) must be changed for the nozzle type shown in the "Preset" column.