00192662-01.pdf - 第480页
10 Component handling User Manual SIPLACE F5/F5 HM 10.10 Surftape feeder m odule (with DCA option only) Software version S R.407.xx 01/2001 US Edition 480 under po wer stage 14. Power rec ord 14 i n the ax is recor d for…

User Manual SIPLACE F5/F5 HM 10 Component handling
Software version SR.407.xx 01/2001 US Edition 10.10 Surftape feeder module (with DCA option only)
479
\ Gehaeuseform-Nr. \ 2011, Consec. package form for special treatment 0:off, PF no.
\ R: Offset Abholhoehe [1/10mm] \ 0, Reserved none
\ R: Verweilzeit Abholen [0.01s] \ 0, Reserved none
\ Verweilzeit Bestuecken [0.01s] \ 50, Wait time during placement with Z axis downtime value
\ Kraftstufe beim Bestuecken \ 0, Power stage during placement 0:standard, X:other
\ R: Offset Kleberhoehe [1/100mm] \ 0, Reserved none
\ Reserve \ 0> Reserved none
etc. up to:
\ Gehaeuseform 100 \
\ Gehaeuseform-Nr. \ 714, Consec. package form for special treatment 0:off, PF no.
\ R: Offset Abholhoehe [1/10mm] \ 0, Reserved none
\ R: Verweilzeit Abholen [0.01s] \ 0, Reserved none
\ Verweilzeit Bestuecken [0.01s] \ 100, Wait time during placement with Z axis downtime value
\ Kraftstufe beim Bestuecken \ 0, Power stage during placement 0:standard, X:other
\ R: Offset Kleberhoehe [1/100mm] \ 0, Reserved none
\ Reserve \ 0 Reserved none
– Save the modified DCA.MA file.
– Close the editor.
PLEASE NOTE:
You must restart the station computer before the changes to the DCA.MA file can take effect. 10
– Shut down the station computer.
PLEASE NOTE:
Do not just switch off the computer. Use ’Exit’ from the ’Start’ menu to shut down WINDOWS. If
you do not do this, you will lose your data because it was not saved. It is also possible to damage
your file system. 10
– Reboot the station computer.
The new machine data will be loaded when you restart the program.
Notes on editing the DCA.MA file:
*1) Exclusive OR function:
Only one function may be used at any given time. If ‘Wait time during placement’ is active,
the surf tape feeder function must be deactivated.
PLEASE NOTE
The ’Wait time during placement’ function is a special option and must be switched off during
placement from surf tape feeders.
*2) The power stage for picking up components from the surf tape feeder module can be con-
verted from the standard value 0 (= power stage 1) to the values set in the KRAFT.MA file

10 Component handling User Manual SIPLACE F5/F5 HM
10.10 Surftape feeder module (with DCA option only) Software version SR.407.xx 01/2001 US Edition
480
under power stage 14.
Power record 14 in the axis record for the Z axis concerned (SP head, IC head) is reserved
for this setting.
*3) The time required to extend the pusher needle depends on the travel of the selected pusher
needle. Check chapter 16 of the feeder module operating instructions for setting the pusher
needle travel.
10.10.4 Settings when starting for the first time
1. Set the switch options for the surf tape feeder to “1”.
2. You can select a pick-up force other than the standard force (see *2, Page 479
).
3. Modify the ‘Wait time for pusher needle‘ and ‘Foil removal time‘ feeder data to suit the feeder
type used.
4. Enter the package form numbers, specifying the wait time during placement in the package
form arrays (SP head and/or IC head) for placement from surf tape feeders.
5. You can enter a placement force other than the standard force.
10.10.5 Maintaining the DCA.MA file
1. Maintain the following feeder data for all the feeder types used:
Å ’Wait time for pusher needle‘
Å ’Foil removal time‘
2. Maintain the package form numbers, specifying the wait time during placement in the pack-
age form arrays (SP head and/or IC head) for placement from surf tape feeders.
10
10

User Manual SIPLACE F5/F5 HM 11 Station extensions /Hardware
Software version SR.407.xx 01/2001 US Edition 11.1 Nozzle changer for the 12-segment Collect&Place head
481
11 Station extensions /Hardware
11.1 Nozzle changer for the 12-segment Collect&Place
head
11.1.1 Overview
A nozzle changer for the 12-segment Collect&Place head can be installed, without loss of feeder
locations, to the left of the PCB conveyor. This enables the nozzle configuration to be changed
quickly, thus allowing the Collect&Place head to be quickly adapted to the needs of the placement
process. 11
The nozzle changer consists of at least one and up to seven magazines, each with twelve nozzle
holders (see Fig. 11.1 - 1
). The magazines are mounted on a common WPC tray.Each magazine
is centered using two parallel pins, and fixed in place with a screw. 11
11.1.2 Technical data - Nozzle changer for the 12-segment Collect&Place head
11
Nozzle changer for the 12-segment Collect&Place head
Dimensions (length x width x height) 560 mm x 60 mm x 46 mm
Number of nozzle holders min.12 / max. 84
Nozzle types 9xx (F
5
HM), 7xx (F
5
)
Time required to open and close the locking plate < 200 ms
Capacity of the reject bin approx. 50 nozzles
Pneumatic system 5.3 bar air line