TRS GEM Manual for Intel Ver 1.1 - 第109页
GEM Manual for DEK P rinters Equipment Va riables Issue 1.1 March 20th, 2014 Page 109 of 152 Page 109 of 152 7.4 Discre te Data Variables The discrete data va riables are define d in the table below: Name DVID Lim its Mo…

GEM Manual for DEK Printers Equipment Variables
Issue 1.1 March 20th, 2014 Page 108 of 152 Page 108 of 152
Name
SVID
Limits
Monitor
Description
Type
Value Range
screen_status
1024
No
The position of the screen in the
printer chase.
U1
1 = No screen.
2 = Screen loaded.
3 = Unloaded at front.
4 = Unloaded at rear.
5 = Screen in chase, but not
loaded.
software_version_param
1025
No
The software version to be stored in
the process program file that indicates
the version of software that last
modified the file.
A20
SSS Version MM.mm
SSS = Source machine type.
MM = Major version level.
mm = Minor version level.
SpoolCountActual
1026
No
Used to keep a count of the messages
actually contained in the printer's
spool area. Multi-block inquire/grant
messages are not
spooled and not included in this count.
U4
0 to 2000 (absolute maximum)
SpoolCountTotal
1027
No
Used to keep a count of the total
number of primary messages directed
to the spool, regardless of whether
placed or retained in the
spool. Multi-block inquire/grant
messages are not spooled and not
included in this count.
U4
0 to 0xFFFFFFFF
SpoolFullTime
1028
No
Contains the timestamp from the time
the spool last became full. If the spool
was not filled during the last spooling
period, this will contain a time value
prior to the current SpoolStartTime.
A12/A16
Yymmddhhmmss
Yyyymmddhhmmsscc
SpoolStartTime
1029
No
Contains the timestamp from the time
spooling last became active.
A12/A16
Yymmddhhmmss
Yyyymmddhhmmsscc
Reserved
1030 -
1049
Not used by the 265.
PPChangeName
1050
No
The name of the last process program
changed (created, modified or deleted)
A68
PPChangeStatus
1051
No
The change operation last performed
A20
PPError
1052
No
Details of any failed product
validation after up/download
A68
PPFormat
1053
No
The format of DEK process programs
U4
Always 1 - Unformatted

GEM Manual for DEK Printers Equipment Variables
Issue 1.1 March 20th, 2014 Page 109 of 152 Page 109 of 152
7.4 Discrete Data Variables
The discrete data variables are defined in the table below:
Name
DVID
Limits
Monitor
Description
Type
Value Range
GemAlarmId
2001
No
Identity of alarm transition.
U4
See chapter 6.
pp_old_file_name
2002
No
Name of process program being
changed.
A68
Any characters valid in a
Windows filename.
pp_change_status
2003
No
Type of process program change.
U1
1 = Load process program
2 = Rename process program
3 = Erase process program
measured_cycle_time
2004
Yes
The duration in seconds of the
most recent machine cycle.
F8
0 = no data
to 3.2 million seconds
throughput_cycle_time
2005
Yes
The average duration in seconds of
the machine cycle time. Averaged
over the last 1 to 50 cycles.
F8
0 = no data
to 3.2 million seconds
Reserved
2006
No
ecid_changed
2007
No
VID of changed equipment
constant.
U4
front_print_pressure
2008
Yes
Front squeegee pressure of last
cycle.
F8
0-20 Kg
rear_print_pressure
2009
Yes
Rear squeegee pressure of last
cycle.
F8
0-20 Kg
print_speed
2010
Yes
Speed measured during the last
print stroke.
F8
2-150 mm/s
table_separation_speed
2011
Yes
Speed of board and screen
separation measured during last
print cycle.
F8
0.1-20 mm/s
board_stretch_error
2012
Yes
Difference between board and
screen fiducials measured after the
print cycle.
F8
5.0 mm
Xerr
2013
Yes
X alignment accuracy.
F8
0.025 mm
Yerr
2014
Yes
Y alignment accuracy.
F8
0.025 mm
theta_err
2015
Yes
Theta alignment accuracy.
F8
arcsec
Squeegee
2016
No
Squeegee used to perform the last
print.
U1
0 = No action.
1 = Front squeegee.
2 = Rear squeegee.
current_screen_bar_code
2017
No
The barcode of the current screen
as scanned when the screen was
loaded.
The default is “NO CODE”.
A32
Up to a 32 character string.
The actual length is
determined by the barcode.
old_time
2018
No
The previous value of the clock
before it was last changed.
A12
A16
Yymmddhhmmss
Yyyymmddhhmmsscc
new_time
2019
No
The time that the clock was last
changed.
A12/
A16
Yymmddhhmmss
Yyyymmddhhmmsscc
product_bar_code
2020
No
The most recent barcode scanned
by the product barcode reader. The
default is “NO CODE”.
A32
Up to a 32 character string.
The actual length is
determined by the barcode.
board_fiducial_1_score
2021
Yes
The acceptance score of board
fiducial 1.
U4
0-1000
board_fiducial_2_score
2022
Yes
The acceptance score of board
fiducial 2.
U4
0-1000
board_fiducial_3_score
2023
Yes
The acceptance score of board
fiducial 3.
3 fiducial mode must be selected.
U4
0-1000
screen_fiducial_1_score
2024
Yes
The acceptance score of screen
fiducial 1.
U4
0-1000

GEM Manual for DEK Printers Equipment Variables
Issue 1.1 March 20th, 2014 Page 110 of 152 Page 110 of 152
Name
DVID
Limits
Monitor
Description
Type
Value Range
screen_fiducial_2_score
2025
Yes
The acceptance score of screen
fiducial 2.
U4
0-1000
screen_fiducial_3_score
2026
Yes
The acceptance score of screen
fiducial 3.
3 fiducial mode must be selected.
U4
0-1000
LimitVariable
2027
No
This variable contains the VID for
the variable whose value changed
monitoring zones.
U4
See list of VID’s for limits
monitoring.
EventLimit
2028
No
This variable contains the
LIMITID of the limit reached or
crossed by LimitVariable. Since
multiple zone transitions for a
variable may occur simultaneously,
EventLimit has been defined to
allow for a list of LIMITIDs.
List of
U1
1-7
TransitionType
2029
No
This variable defines the direction
of the zone transition that has
occurred.
B
1 byte
0 = Transition from lower
zone to upper zone.
1 = Transition from upper
zone to lower zone.
RemoteBarCode
2030
No
Product bar code string provided
by the serial bar code reader.
The default is “NO CODE”.
A32
Up to a 32 character string.
The actual length is
determined by the barcode.
ProflowPastePressure
2031
Yes
Actual Paste Pressure used by the
Proflow paste mechanism.
F8
0-20 Kg
Reserved
2032
No
Not used by the 265.
Traceability Data
2033
No
List of traceability data for the last
processed product.
Variable
See <Traceability Data>
Failed verification item
2034
No
List of the items that last failed
verification
Variable
See <Failed Verification
Items>
Reserved
2083
No
Reserved
2084
No
Reserved
2085
No
Not used.
front_print_speed
2086
Yes
Speed measured during the last
front print stroke.
F8
2-150 mm/s
rear_print_speed
2087
Yes
Speed measured during the last rear
print stroke.
F8
2-150 mm/s
Modified Parameters
2088
No
This variable contains the
parameter ID, name, old value and
new value for the parameters
whose value changed at instrument.
Modifie
d
Paramet
er List
See <Modified Parameter
List>
PrintDeposits
2090
No
This variable contains the number
of print deposits during a print
cycle.
U1
1-10
PrintSpeedDeposit1 to
PrintSpeedDeposit10
2091 to
2100
No
These variables contain the print
stroke speeds for their
corresponding print deposit during
a print cycle.
F8
2-300 mm/s
CleanRate1
2151
No
This variable contains the 1st rate
at which a clean takes place during
a print cycle.
U4
0-100
CleanRate2
2152
No
This variable contains the 2nd rate
at which a clean takes place during
a print cycle.
U4
0-100
LastCleanType
2153
No
This variable contains the last clean
type that took place.
A32
Up to a 32 character string
representing the clean type.