GEM Manual for DEK P rinters SECS II Implementation Issue 1.1 March 20th, 2014 Page 62 of 152 Page 62 of 152 Data Item Description Values Format STRACK Spool stream acknow ledge. 1 = Spooling illegal for stream. e.g. str…

100%1 / 152
GEM Manual for DEK Printers SECS II Implementation
Issue 1.1 March 20th, 2014 Page 61 of 152 Page 61 of 152
Data Item
Description
Values
Format
OBJSPEC
A text string that has an internal format that is
used to point to a specific object instance.
This may be zero length
Not implemented in this release
ASCII
OBJTYPE
Identifier for a group or class of objects
“PROCESS PROGRAM”
“CONFIG”
ASCII *40
OFLACK
Acknowledge code for Off-Line request.
0 = Acknowledge
binary*1
ONLACK
Acknowledge code for On-Line request.
0 = Accepted.
1 = Not allowed.
2 = Already On-Line.
binary*1
PPBODY
Process program body.
Unformatted data.
binary
PPGNT
Process program grant code.
0 = Permission granted.
1 = Already have.
2 = No space.
3 = Invalid PPID.
4 = Busy, try later.
5 = Will not accept.
6-63 Reserved
int*1
PPID
Process program identity.
Any characters valid in a
Windows file name.
ASCII* 
RCMD
Remote command string.
See appendix A.
ASCII* 
READLN
Maximum length to read.
int*2
RECLEN
Maximum length of discrete record.
int*2
REPGSZ
Report group size.
Limit = (no of groups * no of
SVID’s) < 16384 bytes
0-16384 bytes are buffered.
TIAACK = 1 if exceeded.
unsigned int*4
RPTID
Report identity.
Any 4 byte integer no.
unsigned int*4
RSDA
Request spooled data acknowledge.
0 = OK will transmit.
1 = Denied, busy try later.
2 = Denied, spooled data
unknown.
binary
RSDC
Request spooled data code.
0 = Transmit spooled messages.
1 = Purge spooled messages.
unsigned int*1
RSPACK
Reset spooling acknowledge.
0 = Spooling setup accepted.
1 = Spooling setup rejected.
binary*1
RTYPE
Type of record.
1 = Discrete type.
int*1
SHEAD
Stored header associated with transaction
timeout.
See SECSI specification for
format of header block.
binary*10
SMPLN
Sample number. When REPGSZ > 1 then it
is the sample number of the first sample in
the report.
0-4294967295
unsigned int*4
SOFTREV
Software revision code.
“V” MM ”R” mm
MM = Major version level.
mm = Minor version level.
ASCII*6
STIME
Sample time.
Yymmddhhmmss or
Yyyymmddhhmmsscc
ASCII*12 or
ASCII*16
Depends on
variable
TimeFormat
GEM Manual for DEK Printers SECS II Implementation
Issue 1.1 March 20th, 2014 Page 62 of 152 Page 62 of 152
Data Item
Description
Values
Format
STRACK
Spool stream acknowledge.
1 = Spooling illegal for stream.
e.g. stream 1
2 = Unknown stream.
3 = Unknown function for this
stream.
4 = Secondary function
specified for this stream.
binary*1
STRID
Stream identity.
Any supported stream number.
unsigned int*1
SV
Status variable value.
See chapter 7, Machine
Variables.
Depends upon
variable id.
SVID
Status variable identity.
See chapter 7.
unsigned int*4.
SVNAME
Status variable name.
See chapter 7.
ASCII* 
TEXT
Character string for terminal display.
Any printable characters.
ASCII* 
TIAACK
Trace request acknowledge code.
0 = Acknowledge, OK.
1 = Too many SVID’s.
2 = No more traces allowed.
3 = Invalid period.
binary*1
TIACK
Time send acknowledge code.
0 = Accepted
1 = Error
binary*1
TID
Terminal number.
0 = Single terminal.
binary*1
TIME
Time of day.
Yymmddhhmmss or
Yyyymmddhhmmsscc
7
ASCII*12 or
ASCII*16
Depends on
variable
TimeFormat
TOTSMP
Total number of samples to be taken.
0-4294967295
unsigned int*4
TRID
Trace requests identity.
0-4294967295
unsigned int*4
UNITS
Units identifier.
‘s’ = seconds
‘cs’ = centiseconds
‘ms’ = milliseconds
ASCII* 
UPPERDB
A variable limit attribute that defines the
upper boundary of the deadband of a limit.
The value applies to a single limit (LIMITID)
for a specified VID.
Thus, UPPERDB and LOWERDB as a pair
define a limit.
See Variable limits section 5.5
Depends on the
type of the
variable.
V
Variable data.
See chapter 5, Machine
Variables.
Depends upon
variable id.
VID
Variable identity.
See chapter 5, Machine
Variables.
unsigned int*4.
VLAACK
Variable limit attribute acknowledge code.
0 = Command will be done.
1 = Attribute definition error.
2 = Cannot do now.
binary*1
7
If yy is less than 96 then yy is assumed to be 2000 + yy
GEM Manual for DEK Printers SECS II Implementation
Issue 1.1 March 20th, 2014 Page 63 of 152 Page 63 of 152
6.3 STREAM 1: EQUIPMENT STATUS
S1F1 Are You There Request (R)
S1F2 On-Line Data (D)
Description: This transaction determines whether the receiver is alive and able to
respond. It can also trigger transition to the ON-LINE control state.
A. Host Initiated
Host to equipment: S1F1
Structure: Header only
Equipment to host: S1F2
Structure: L,2
1. <MODLN>
2. <SOFTREV>
B. Equipment Initiated
Equipment to host: S1F1
Structure: Header only
Host to equipment: S1F2
Structure: L,0