CP43操作手册.pdf.pdf - 第223页

• Action of the Function Keys D1 MAX : Press to set the D1 max calibration r esults in Proper data. D2 MAX : Press to set the D2 max calibration r esults in Proper data. Z MAX : Press to set the Z max calibration r esult…

100%1 / 364
Action of the Function Keys
D1 ORIGIN :Press to set the D1 origin calibration results
in Proper data.
D2 ORIGIN :Press to set the D2 origin calibration results
in Proper data.
Z0 :Press to set the Z0 calibration results into
Proper data.
Note: Pressing any of the above commands will display "SET."
Press [SET] to set the Proper data.
RETURN :Press to return to Page 533/000.
First Display Area
Proper Data
D Axis PICKUP POS..T1 : 2474 Mode : 1
PICKUP POS. T2 : 58474 Servo Counter
D1 ORIGIN : 116208 X 000000
D2 ORIGIN : -390 Y 000000
Origin Pos. Z0 : 0 C 359880
Max Limit Pos. D1max : 500 D1 -482476
D2max : 492756 D2 -000001
Zmax : 1000 Z 000000
Min Limit Pos. D1min : -492531 FQ 000005
D2min : -500 World (Zero)
Zmin : -3000
For detailed information on setting Proper data refer to the FCP IV-3 Maintenance
Manual.
Function Key Menu
Chapter 3 Description of Commands
To Page 533/110
To Page 533/110
To Page 533/110
To Page 533/000
Setting D, Z Axis
Origin Positions
Part 3
3 – 97
ORIGIN
Page
533 200
D1 ORIGIN D2 ORIGIN Z 0 RETURN
Version 5.0
FCP IV-3 Operation
Action of the Function Keys
D1 MAX :Press to set the D1 max calibration results in
Proper data.
D2 MAX :Press to set the D2 max calibration results in
Proper data.
Z MAX :Press to set the Z max calibration results in
Proper data.
Note: Pressing either of the above commands will display "SET."
Press [SET] to set the Proper data.
RETURN :Press to return to Page 533/000.
First Display Area
Proper Data
D Axis PICKUP POS..T1 : 2474 Mode : 1
PICKUP POS. T2 : 58474 Servo Counter
D1 ORIGIN : 116208 X 000000
D2 ORIGIN : -390 Y 000000
Origin Pos. Z0 : 0 C 359880
Max Limit Pos. D1max : 500 D1 -482476
D2max : 492756 D2 -000001
Zmax : 1000 Z 000000
Min Limit Pos. D1min : -492531 FQ 000005
D2min : -500 World (Zero)
Zmin : -3000
For detailed information on setting Proper data refer to the FCP IV-3 Maintenance
Manual.
Function Key Menu
Chapter 3 Description of Commands
Setting D, Z Axis
Positive Stroke
Part 3
3 – 98
MAX LIMIT
Page
533 300
D1 MAX D2 MAX Z MAX RETURN
Version 5.0
FCP IV-3 Operation
To Page 533/110
To Page 533/110
To Page 533/110
To Page 533/000
Action of the Function Keys
D1 MIN :Press to set the D1 min calibration results in
Proper data.
D2 MIN :Press to set the D2 min calibration results in
Proper data.
Z MIN :Press to set the Z min calibration results in
Proper data.
Note: Pressing either of the above commands will display "SET."
Press [SET] to set the Proper data.
RETURN :Press to return to Page 533/000.
First Display Area
Proper Data
D Axis PICKUP POS..T1 : 2474 Mode : 1
PICKUP POS. T2 : 58474 Servo Counter
D1 ORIGIN : 116208 X 000000
D2 ORIGIN : -390 Y 000000
Origin Pos. Z0 : 0 C 359880
Max Limit Pos. D1max : 500 D1 -482476
D2max : 492756 D2 -000001
Zmax : 1000 Z 000000
Min Limit Pos. D1min : -492531 FQ 000005
D2min : -500 World (Zero)
Zmin : -3000
For detailed information on setting Proper data refer to the FCP IV-3 Maintenance
Manual.
Function Key Menu
Chapter 3 Description of Commands
To Page 533/110
To Page 533/110
To Page 533/110
To Page 533/000
Setting D, Z Axis
Negative Stroke
Part 3
3 – 99
MIN LIMIT
Page
533 400
D 1 MIN D 2 MIN Z MIN RETURN
Version 5.0
FCP IV-3 Operation