Chapter 2 Details of Proper Data Part 4 47: ID Station T ype S_type: A_type $ ❈ On HELPS-compatible machines, sets the location of the ID station. S_type: The ID station is in the machine. A_type: The ID station is outsi…

100%1 / 364
Chapter 2 Details of Proper DataPart 4
41: Cell Status Unit: Active: Passive $#
This is valid only for HELPS-compatible machines. This sets cell status.
Unit: Unit cell
Active: Active cell
Passive: Passive cell
The standard setting is "Unit."
42: Change Over Mode 0 ~ 200 $#
This is valid only for HELPS-compatible machines. The standard setting
is 0.
43: Auto Start No: Yes $#
This is valid only for HELPS-compatible machines. It sets the start-up
method after changeover has finished.
No: Machine waits for [START] button to be pressed after changeover
is finished.
Yes: Automatic start.
The standard setting is "No."
44: Backup Plate Check No: Yes $#
On HELPS-compatible machines, this determines whether a backup plate
check will be done during changeover.
No: No backup plate changeover check.
Yes: Backup plate changeover check.
The standard setting is "No."
45: Command Line Status RS232C: LAN $
This sets the mode of transmission with LMS.
RS232C: Use RS232C
LAN: Use LAN
ETHERNET: Use Ethernet
The standard setting is "RS232C."
46: Command Line Port 0 ~ 30 $#
On HELPS-compatible machines, use the command line to set the RS232C
ports that will be used.
0: Command line will not be used.
1 - 8: Port numbers.
The standard setting is 0.
4 – 25Version 5.0
FCP IV-3 Operation
Chapter 2 Details of Proper DataPart 4
47: ID Station Type S_type: A_type $
On HELPS-compatible machines, sets the location of the ID station.
S_type: The ID station is in the machine.
A_type: The ID station is outside the machine.
The standard setting is "A_type."
48: Buzzer warning On: Off $#
On HELPS-compatible machines, this sets whether or not a buzzer sounds
during changeover operator prompts.
On: Buzzer will sound.
Off: Buzzer will not sound.
The standard setting is "On."
49: Process Timer 1 ~ 120000 [msec] $#
On HELPS-compatible machines, this sets the protocol timer value. The
standard setting is 10000 msec.
50: Reader Type 0 ~ 9 $#
On HELPS-compatible machines, when using a bar code reader, this sets
the type of code reader.
0: Bar code reader
1: Pattern code reader
Other: Bar code reader
The standard setting is 0.
51: Code Reader Timer 1 ~ 120000 [msec] $#
This sets the amount of time allowed for a bar code reader to read a board
type code. The standard setting is 10000 [msec].
52: Code Reader Retry 0 ~ 10 $#
This sets the number of times a code reader will read a board again in case
of a misreading the first time. The standard setting is 0.
53: Reader1 Port No. 0 ~ 30 $#
This is valid only for HELPS-compatible machines. Sets the four channel
port number for code reader 1 (top surface).
0: Not used
1 ~ 30: Connector number of the four channel communication board.
The standard setting is 0.
Version 5.0 4 – 26
FCP IV-3 Operation
Chapter 2 Details of Proper DataPart 4
54: Reader 2 Port No. 0 ~ 30 $#
This is valid only for HELPS-compatible machines. Sets the port number
for code reader 2 (bottom surface).
0: Not Used
1 ~ 30: Connector number of the four channel communication board.
The standard setting is 0.
55: PCB Code Terminal Non: Use $#
This sets whether or not a Handy Terminal is used for recovery.
Non: Not Used
Use: Used
The standard setting is "No."
56: Terminal Type CRX1200: VT-100 $
Not currently in use. The standard setting is "CRX1200."
57: Code Terminal Port 0 ~ 8 $#
When a Handy Terminal is used for recovery, this sets the four channel port
number for the code reader.
0: Handy Terminal is not used for recovery.
1 ~ 30: Port number
The standard setting is 0.
70: Device Check SW No: Parts Miss Error #
This sets whether or not a compulsory device check will be performed after
running out of parts, or after a program has been changed.
No: No mandatory device check
Parts: Perform mandatory device check when parts run out.
Miss: Perform mandatory device check when parts run out or when parts
are mispicked.
Error: Perform mandatory device check when parts run out, parts are
mispicked or when a vision processing error occurs.
The standard setting is "Parts."
4 – 27Version 5.0