CP43操作手册.pdf.pdf - 第278页

Chapter 2 Details of Proper Data Part 4 151: Reach Pulse C 0 ~ 65535 [pulse] ✩❈ This exactly aligns the C axis servos. If this value is changed the machine will not operate normally , so exercise extreme caution. The sta…

100%1 / 364
Chapter 2 Details of Proper DataPart 4
143:Rough Pulse D2 0 ~ 65535 [pulse] ✩❈
This roughly aligns the D2 axis servos.
If this value is changed the machine will not operate normally, so exercise
extreme caution. The standard setting is 30.
144:Rough Pulse C 0 ~ 65535 [pulse] ✩❈
This roughly aligns the C axis servos. The standard setting is 10.
If this value is changed the machine will not operate normally, so exercise
extreme caution. The standard setting is 10.
145:Rough Pulse FQ 0 ~ 65535 [pulse] ✩❈
This roughly aligns the FQ axis servos.
If this value is changed the machine will not operate normally, so exercise
extreme caution. The standard setting is 10.
146:Rough Pulse Z 0 ~ 65535 [pulse] ✩❈
This roughly aligns the Z axis servos.
If this value is changed the machine will not operate normally, so exercise
extreme caution. The standard setting is 100.
147:Reach Pulse X 0 ~ 65535 [pulse] ✩❈
This exactly aligns the X axis servos.
If this value is changed the machine will not operate normally, so exercise
extreme caution. The standard setting is 3.
148:Reach Pulse Y 0 ~ 65535 [pulse] ✩❈
This exactly aligns the Y axis servos.
If this value is changed the machine will not operate normally, so exercise
extreme caution. The standard setting is 3.
149:Reach Pulse D1 0 ~ 65535 [pulse] ✩❈
This exactly aligns the D1 axis servos.
If this value is changed the machine will not operate normally, so exercise
extreme caution. The standard setting is 20.
150:Reach Pulse D2 0 ~ 65535 [pulse] ✩❈
This exactly aligns the D2 axis servos.
If this value is changed the machine will not operate normally, so exercise
extreme caution. The standard setting is 20.
4 – 39Version 5.0
FCP IV-3 Operation
Chapter 2 Details of Proper DataPart 4
151:Reach Pulse C 0 ~ 65535 [pulse] ✩❈
This exactly aligns the C axis servos.
If this value is changed the machine will not operate normally, so exercise
extreme caution. The standard setting is 3.
152:Reach Pulse FQ 0 ~ 65535 [pulse] ✩❈
This exactly aligns the FQ axis servos.
If this value is changed the machine will not operate normally, so exercise
extreme caution. The standard setting is 3.
153:Reach Pulse Z 0 ~ 65535 [pulse] ✩❈
This exactly aligns the Z axis servos.
If this value is changed the machine will not operate normally, so exercise
extreme caution. The standard setting is 20.
160:SA Place Offset X -327.68 ~ 327.68 [mm] ✩❈
171:SL Place Offset X -327.68 ~ 327.68 [mm] ✩❈
This sets the amount of X direction offset for the S nozzle position at
station 7.
If this value is changed the machine will not place parts accurately.
The standard setting is the Proper data calibration result. Refer to the
FCP IV-3 Maintenance Manual for further details on Proper data
measurement.
172:MA Place Offset X -327.68 ~ 327.68 [mm] ✩❈
183:ML Place Offset X -327.68 ~ 327.68 [mm] ✩❈
This sets the amount of X direction offset for the M nozzle position at
station 7.
If this value is changed the machine will not place parts accurately.
The standard setting is the Proper data calibration result. Refer to the
FCP IV-3 Maintenance Manual for further details on Proper data
measurement.
Version 5.0 4 – 40
FCP IV-3 Operation
Chapter 2 Details of Proper DataPart 4
184:LA Place Offset X- 327.68 ~ 327.68 [mm] ✩❈
195:LL Place Offset X -327.68 ~ 327.68 [mm] ✩❈
This sets the amount of X direction offset for the L nozzle position at
station 7.
If this value is changed the machine will not place parts accurately.
The standard setting is the Proper data calibration result. Refer to the
FCP IV-3 Maintenance Manual for further details on Proper data
measurement.
196:SA Place Offset Y -327.68 ~ 327.68 [mm] ✩❈
207:SL Place Offset Y -327.68 ~ 327.68 [mm] ✩❈
This sets the amount of Y direction offset for the S nozzle position at
station 7.
If this value is changed the machine will not place parts accurately.
The standard setting is the Proper data calibration result. Refer to the
FCP IV-3 Maintenance Manual for further details on Proper data
measurement.
208:MA Place Offset Y -327.68 ~ 327.68 [mm] ✩❈
219:ML Place Offset Y -327.68 ~ 327.68 [mm] ✩❈
This sets the amount of Y direction offset for the M nozzle position at
station 7.
If this value is changed the machine will not place parts accurately.
The standard setting is the Proper data calibration result. Refer to the
FCP IV-3 Maintenance Manual for further details on Proper data
measurement.
4 – 41Version 5.0
FCP IV-3 Operation