CP43操作手册.pdf.pdf - 第279页
Chapter 2 Details of Proper Data Part 4 184: LA Place Of fset X - 327.68 ~ 327.68 [mm] ✩❈ ⇓ 195: LL Place Of fset X -327.68 ~ 327.68 [mm] ✩❈ This sets the amount of X direction of fset for the L nozzle position at statio…

Chapter 2 Details of Proper DataPart 4
151:Reach Pulse C 0 ~ 65535 [pulse] ✩❈
This exactly aligns the C axis servos.
If this value is changed the machine will not operate normally, so exercise
extreme caution. The standard setting is 3.
152:Reach Pulse FQ 0 ~ 65535 [pulse] ✩❈
This exactly aligns the FQ axis servos.
If this value is changed the machine will not operate normally, so exercise
extreme caution. The standard setting is 3.
153:Reach Pulse Z 0 ~ 65535 [pulse] ✩❈
This exactly aligns the Z axis servos.
If this value is changed the machine will not operate normally, so exercise
extreme caution. The standard setting is 20.
160:SA Place Offset X -327.68 ~ 327.68 [mm] ✩❈
⇓
171:SL Place Offset X -327.68 ~ 327.68 [mm] ✩❈
This sets the amount of X direction offset for the S nozzle position at
station 7.
If this value is changed the machine will not place parts accurately.
The standard setting is the Proper data calibration result. Refer to the
FCP IV-3 Maintenance Manual for further details on Proper data
measurement.
172:MA Place Offset X -327.68 ~ 327.68 [mm] ✩❈
⇓
183:ML Place Offset X -327.68 ~ 327.68 [mm] ✩❈
This sets the amount of X direction offset for the M nozzle position at
station 7.
If this value is changed the machine will not place parts accurately.
The standard setting is the Proper data calibration result. Refer to the
FCP IV-3 Maintenance Manual for further details on Proper data
measurement.
Version 5.0 4 – 40
FCP IV-3 Operation

Chapter 2 Details of Proper DataPart 4
184:LA Place Offset X- 327.68 ~ 327.68 [mm] ✩❈
⇓
195:LL Place Offset X -327.68 ~ 327.68 [mm] ✩❈
This sets the amount of X direction offset for the L nozzle position at
station 7.
If this value is changed the machine will not place parts accurately.
The standard setting is the Proper data calibration result. Refer to the
FCP IV-3 Maintenance Manual for further details on Proper data
measurement.
196:SA Place Offset Y -327.68 ~ 327.68 [mm] ✩❈
⇓
207:SL Place Offset Y -327.68 ~ 327.68 [mm] ✩❈
This sets the amount of Y direction offset for the S nozzle position at
station 7.
If this value is changed the machine will not place parts accurately.
The standard setting is the Proper data calibration result. Refer to the
FCP IV-3 Maintenance Manual for further details on Proper data
measurement.
208:MA Place Offset Y -327.68 ~ 327.68 [mm] ✩❈
⇓
219:ML Place Offset Y -327.68 ~ 327.68 [mm] ✩❈
This sets the amount of Y direction offset for the M nozzle position at
station 7.
If this value is changed the machine will not place parts accurately.
The standard setting is the Proper data calibration result. Refer to the
FCP IV-3 Maintenance Manual for further details on Proper data
measurement.
4 – 41Version 5.0
FCP IV-3 Operation

Chapter 2 Details of Proper DataPart 4
220:LA Place Offset Y -327.68 ~ 327.68 [mm] ✩❈
⇓
231:LL Place Offset Y - 327.68 ~ 327.68 [mm] ✩❈
This sets the amount of Y direction offset for the L nozzle position at
station 7.
If this value is changed the machine will not place parts accurately.
The standard setting is the Proper data calibration result. Refer to the
FCP IV-3 Maintenance Manual for further details on Proper data
measurement.
232:Device Offset 1 -32.768 ~ 32.768 [mm] #
⇓
391:Device Offset 140 -32.768 ~ 32.768 [mm] #
This sets the amount of device offset for picking parts. Input is entered in
units of 0.001 mm. If a vision processing error is generated due to parts
slippage (left-right) caused by the condition of the feeder or the tape, this
offset value can be changed to allow the part to be picked closer to the
center of the part. The value input normally offsets only the device for
which it has been input. It is also possible to set this value on the machine
with the editor.
The standard setting is the Proper data calibration result. Refer to the
FCP IV-3 Maintenance Manual for further details on Proper data
measurement.
401:Mark Camera Pixel X 0 ~ 4000000 ❈
This sets the size of 1 pixel in the X direction for the mark camera. The
value that displays here must be divided by a factor of 65536 to obtain a
value expressed in µm units. The user cannot change this setting.
The standard setting is the Proper data measurement result, which upon
measurement must be transmitted from the machine to the MCS 30
computer.
402:Mark Camera Pixel Y 0 ~ 4000000 ❈
This sets the size of 1 pixel in the Y direction for the mark camera. The
value that displays here must be divided by a factor of 65536 to obtain a
value expressed in µm units. The user cannot change this setting.
The standard setting is the Proper data measurement result, which upon
measurement must be transmitted from the machine to the MCS 30
computer.
Version 5.0 4 – 42
FCP IV-3 Operation