Chapter 2 Details of Proper Data Part 4 468: Nozzle X L Head A W ide 0 ~ 30000000 ❈ ⇓ 479: Nozzle X L Head L W ide 0 ~ 30000000 ❈ When nozzle center measurement is carried out the X coor dinates are set in the above item…

100%1 / 364
Chapter 2 Details of Proper DataPart 4
432:Nozzle Y S Head A Wide 0 ~ 30000000
443:Nozzle Y S Head L Wide 0 ~ 30000000
When nozzle center measurement is carried out the Y coordinates are set in
the above items for the center of rotation of the S nozzle on head A through
L respectively for the wide view parts camera. The value that displays here
must be divided by a factor of 65536 to obtain a value expressed in µm
units.
These standard settings are based on the results of nozzle center
measurement and must be transmitted from the machine to the MCS 30
computer after being measured.
444:Nozzle X M Head A Wide 0 ~ 30000000
455:Nozzle X M Head L Wide 0 ~ 30000000
When nozzle center measurement is carried out the X coordinates are set in
the above items for the center of rotation of the M nozzle on head A
through L respectively for the wide view parts camera. The value that
displays here must be divided by a factor of 65536 to obtain a value
expressed in µm units.
These standard settings are based on the results of nozzle center
measurement and must be transmitted from the machine to the MCS 30
computer after being measured.
456:Nozzle Y M Head A Wide 0 ~ 30000000
467:Nozzle Y M Head L Wide 0 ~ 30000000
When nozzle center measurement is carried out the Y coordinates are set in
the above items for the center of rotation of the M nozzle on head A
through L respectively for the wide view parts camera. The value that
displays here must be divided by a factor of 65536 to obtain a value
expressed in µm units.
These standard settings are based on the results of nozzle center
measurement and must be transmitted from the machine to the MCS 30
computer after being measured.
Version 5.0 4 – 46
FCP IV-3 Operation
Chapter 2 Details of Proper DataPart 4
468:Nozzle X L Head A Wide 0 ~ 30000000
479:Nozzle X L Head L Wide 0 ~ 30000000
When nozzle center measurement is carried out the X coordinates are set in
the above items for the center of rotation of the L nozzle on head A through
L respectively for the wide view parts camera. The value that displays here
must be divided by a factor of 65536 to obtain a value expressed in µm
units.
These standard settings are based on the results of nozzle center
measurement and must be transmitted from the machine to the MCS 30
computer after being measured.
480:Nozzle Y L Head A Wide 0 ~ 30000000
491:Nozzle Y L Head L Wide 0 ~ 30000000
When nozzle center measurement is carried out the Y coordinates are set in
the above items for the center of rotation of the L nozzle on head A through
L respectively for the wide view parts camera. The value that displays here
must be divided by a factor of 65536 to obtain a value expressed in µm
units.
These standard settings are based on the results of nozzle center
measurement and must be transmitted from the machine to the MCS 30
computer after being measured.
492:Nozzle X S Head A Narrow 0 ~ 30000000
503:Nozzle X S Head L Narrow 0 ~ 30000000
When nozzle center measurement is carried out the X coordinates are set in
the above items for the center of rotation of the S nozzle on head A through
L respectively for the narrow view parts camera. The value that displays
here must be divided by a factor of 65536 to obtain a value expressed in µm
units.
These standard settings are based on the results of nozzle center
measurement and must be transmitted from the machine to the MCS 30
computer after being measured.
4 – 47Version 5.0
FCP IV-3 Operation
Chapter 2 Details of Proper DataPart 4
504:Nozzle Y S Head A Narrow 0 ~ 30000000
515:Nozzle Y S Head L Narrow 0 ~ 30000000
When nozzle center measurement is carried out the Y coordinates are set in
the above items for the center of rotation of the S nozzle on head A through
L respectively for the narrow view parts camera. The value that displays
here must be divided by a factor of 65536 to obtain a value expressed in µm
units.
These standard settings are based on the results of nozzle center
measurement and must be transmitted from the machine to the MCS 30
computer after being measured.
516:Nozzle X M Head A Narrow 0 ~ 30000000
527:Nozzle X M Head L Narrow 0 ~ 30000000
When nozzle center measurement is carried out the X coordinates are set in
the above items for the center of rotation of the M nozzle on head A
through L respectively for the narrow view parts camera. The value that
displays here must be divided by a factor of 65536 to obtain a value
expressed in µm units.
These standard settings are based on the results of nozzle center
measurement and must be transmitted from the machine to the MCS 30
computer after being measured.
528:Nozzle Y M Head A Narrow 0 ~ 30000000
539:Nozzle Y M Head L Narrow 0 ~ 30000000
When nozzle center measurement is carried out the Y coordinates are set in
the above items for the center of rotation of the M nozzle on head A
through L respectively for the narrow view parts camera. The value that
displays here must be divided by a factor of 65536 to obtain a value
expressed in µm units.
These standard settings are based on the results of nozzle center
measurement and must be transmitted from the machine to the MCS 30
computer after being measured.
Version 5.0 4 – 48