Chapter 3 MCS Error Code TablePart 6
Error Code: 22007514
MCS Display: DTX7512 Error
Cause: The program’s machine type does not match the previously
transmitted program machine type.
Remedy: Make sure program machine types match.
Error Code: 22007515
Cause: After a download request was made an error occurred in the
MCS/2H program check.
Remedy: Verify the program.
Error Code: 2200AB00
MCS Display: DTXAB00 Error
Cause: After a download request was made an answer was not received
from the machine within the preset time limit.
Remedy: Verify that the machine and MCS 30 are both booted up.
Error Code: 2200AB01
MCS Display: DTXAB01 Error
Cause: A communication error returned from the machine while a
program was being downloaded.
Remedy: Select the [Ctrl] and [E] keys from the UCI menu to obtain a
display of errors. Reference the error codes that have returned
from the machine.
Error Code: 2200AB04
MCS Display: DTXAB04 Error
Cause: The Part data for the requested program does not exist.
Remedy: Use the file services directory to verify whether the Part data file
for the requested program exists or not.
Error Code: 2200AA00
MCS Display: GDXAA00 Error or GQXAA00 Error
Cause: The requested GD file or GQ file does not exist in MCS/2H.
Remedy: Use the file services directory to check for the file.
6 – 16Version 2.0
Chapter 4 Vision Processing ErrorsPart 6
4. Vision Processing Errors
This chapter explains the various vision processing errors which may occur.
4.1 Fiducial Mark and Block Skip Mark Error Messages
Error Code 1C120002
Cause: Either the size of the mark designated in the production
program is different from the mark size actually read during
vision processing or the mark types are different.
Remedy: Verify that the size and type of marks on the board match those
specified in the production program.
Error Code 1C200001
Cause: The mark search range designated in the production program is
too close to the edge of the camera field of vision.
Remedy: Change the production program so that the mark is set in the
center of the field of vision.
Error Code 1C200002
Cause: There was not a distinct enough contrast between the mark and
the mark search area for the mark to be recognized.
Remedy: Obtain a better contrast between the mark and the mark search
area.
6 – 17Version 2.0
Chapter 4 Vision Processing ErrorsPart 6
4.2 Calibration (Proper Data Measurement) Error Messages
Error Code 1C310010
Cause: Training cannot be carried out.
Remedy: Try rebooting the machine. This error generally does not occur.
Error Code 1C310011
Cause: A contradiction occurred during calibration.
Remedy: This error generally does not occur. Reboot the machine.
Error Code 1C310013
Cause: A movement command contradiction occurred during
calibration.
Remedy: This error will probably never occur. If it does, contact Fuji.
Error Code 1C310015
Cause: A movement command contradiction occurred during
calibration.
Remedy: This error will probably never occur. If it does, contact Fuji.
Error Code 310016
Cause: A movement command contradiction occurred during
calibration.
Remedy: This error will probably never occur. If it does, contact Fuji.
Error Code 1C310017
Cause: A movement command contradiction occurred during
calibration.
Remedy: This error will probably never occur. If it does, contact Fuji.
Error Code 310018
Cause: A contradiction occurred in the calibration operation
commands.
Remedy: This error will probably never occur. If it does, contact Fuji.
6 – 18Version 2.0