Chapter 4 V ision Processing Errors Part 6 Error Code 1C410122 Cause: There is no coarse edge. Remedy: When the frontlight is being used a coarse edge is necessary . Check the generic device description. Error Code 1C410…

Chapter 4 Vision Processing ErrorsPart 6
Error Code 1C410114
Cause: L center tolerance check error.
Remedy: Change the center tolerance
lcenter_tolerance.
Error Code 1C410115
Cause: D center tolerance check error.
Remedy: Change the center tolerance
d center_tolerance.
Error Code 1C410116
Cause: H position error. There is slippage at the pick-up point.
Remedy: Determine the causes of the slippage. For example, check the
device offset in Proper data, check that the feeder is working
correctly, etc.
Error Code 1C410117
Cause: V position error. There is slippage at the pick-up point.
Remedy: Determine the causes of the slippage. For example, check the
device offset in Proper data, check that the feeder is working
correctly, etc.
Error Code 1C410118
Cause: Rotational position error. There is too much rotation slippage.
This indicates a part angle pickup error.
Remedy: Check the Proper device offset.
Error Code 1C410120
Cause: Part is too large.
Remedy: Check the relevant specifications of the machine.
Error Code 1C410121
Cause: Part is too large.
Remedy: Check the relevant specifications of the machine.
6 – 21Version 2.0

Chapter 4 Vision Processing ErrorsPart 6
Error Code 1C410122
Cause: There is no coarse edge.
Remedy: When the frontlight is being used a coarse edge is necessary.
Check the generic device description.
Error Code 1C410123
Cause: Pickup tolerance is too large.
Remedy: Decrease the tolerance in the generic device description (refer to
‘total tolerance x,’ ‘total tolerance y’ and ‘rotation tolerance’).
Error Code 1C410124
Cause: Pickup tolerance is too large.
Remedy: Decrease the tolerance in the generic device description (refer to
‘total tolerance x,’ ‘total tolerance y’ and ‘rotation tolerance’).
Error Code 1C410125
Cause: A preset time limit has been exceeded.
Error Code 1C410126
Cause: Even though coarse edge was performed, the pick-up tolerance
is too large.
Remedy: Decrease the tolerance in the generic device description (refer to
‘total tolerance x,’ ‘total tolerance y’ and ‘rotation tolerance’).
Error Code 1C410127
Cause: Coarse edge was not found.
Error Code 1C410128
Cause: Training cannot be carried out because the pickup tolerance is
too large.
Remedy: Decrease the tolerance in the generic device description (refer to
‘total tolerance x,’ ‘total tolerance y’ and ‘rotation tolerance’).
6 – 22Version 2.0

Chapter 4 Vision Processing ErrorsPart 6
Error Code 1C410129
Cause: Training cannot be carried out because the coarse edge is not
correct.
Remedy: Check the generic device description.
Error Code 1C410130
Cause: The coarse edge pickup tolerance is too large.
Remedy: Decrease the tolerance in the generic device description (refer to
‘total tolerance x,’ ‘total tolerance y’ and ‘rotation tolerance’).
Error Code 1C410131
Cause: The coarse edge pickup tolerance is too large.
Remedy: Decrease the tolerance in the generic device description (refer to
‘total tolerance x,’ ‘total tolerance y’ and ‘rotation tolerance’).
Error Code 1C410132
Cause: The blob cannot be seen from the nozzle position.
Error Code 1C410133
Cause: Blob inspection error due to faulty device rotation angle setting.
Error Code 1C410134
Cause: There is insufficient data in the generic device description.
Remedy: Check the generic device description. This error should never
occur.
Error Code 1C410143
Cause: Caliper window does not fit correctly.
Remedy: Decrease the tolerance in the generic device description (refer to
‘total tolerance x,’ ‘total tolerance y’ and ‘rotation tolerance’).
6 – 23Version 2.0