V ersion 2.0 Chapter 5 Data Check Errors Part 6 • Device Description ID No. Check If the device description ID number has not been set in Part data for the chosen device number , the following equation will be displayed.…

Chapter 5 Data Check ErrorsPart 6
Axis Hexadecimal Error Code
X 1101C200 + (Sequence Number/20)
Y 1101C300 + (Sequence Number/20)
Table 6-1
For example, consider that the error code 1101C205 is received from
the machine. Since the error code is 1101C20? this indicates an X axis
error. The final digit is 5, therefore given the equation (Sequence
No./20) (fractions are truncated to integer values) this yields a
sequence number of 5*20 = 100. The error code 11011005 therefore
indicates that an X coordinate between sequence 100 and 119 (100 +
19) lies outside the permissible range. Thus if error code 1101C3??
comes up, deal with it in the same way as shown above.
Remedy: Check the sequence data, and if it is outside the
permissible range, correct it.
• Device Data Check
The machine checks if the device data lies within the limit for each
machine. If the data lies outside the permitted range, the machine
sends the error code determined from equation 3 to MCS/2H.
The maximum number of usable devices on the FCPIV-3 is 160.
Device data error codes (equation 3):
1101C100 + Sequence number/20 (Hexadecimal)
Remedy: Check the sequence data, and if it is outside the
permissible range, correct it.
• Sequence Number Check
If the number of sequences in sequence data and the number of
sequences set in Prog_information (N_max) do not match, error code
11011064 will appear.
Remedy: Correct the discrepancy and retransmit the program.
• Sequence End Check
If the end bit of the sequence data does not achieve parity, error code
11011066 will appear.
Remedy: Retransmit the program.
6 – 28Version 2.0

Version 2.0
Chapter 5 Data Check ErrorsPart 6
• Device Description ID No. Check
If the device description ID number has not been set in Part data for
the chosen device number, the following equation will be displayed.
11011070 + D No/13 (Hexadecimal)
Remedy: Enter ":idg-a" at the UCI menu.
• Chosen Nozzle Check
For the Device numbers being used, if the diameters of the chosen
nozzles have been designated in “Nozzle_size_CP4” in Part data,
check the Machine_data nozzle diameters entered in “S_nozzle_size,”
“M_nozzle_size” and “L_nozzle_size”. Based on the results of this
check, any nozzle that doesn’t match will have the following error
message displayed.
11011080 + D No/13 (Hexadecimal)
Remedy: Check Part data and enter the appropriate nozzle
diameters in Nozzle_size_CP4 and retransmit the
program.
• Maximum Nozzle Diameter Check
Check whether the nozzle diameters in the nozzle data section of
Machine_data are less than the maximum permissible nozzle sizes set
in Part data for the device numbers in use. If the results of this check
are out of range, the following equation will appear as an error
message.
11011090 + D No/13 (Hexadecimal)
Remedy: Check Part data and enter the appropriate maximum
nozzle diameter in “Nozzle_size_max”, then retransmit
the program.
6 – 29

Chapter 5 Data Check ErrorsPart 6
• Minimum Background Disk Size Check
For the device numbers being used, check that the background disk
size set in Machine_data in the production program is smaller than
the minimum background disk size set in Part data. If the results of
this check are out of range, the following equation will appear as an
error message.
1101D040 + D No/13 (Hexadecimal)
Remedy: Check the minimum background disk size set in
"Back_light_min" in Part data or check
"S_back_light_size", "M_back_light_size", and
"L_back_light_size" in Machine_data in the production
program. Input an appropriate size and retransmit the
program.
• Mark Sequence Number Check
If the number of mark sequences in the program (including both
fiducial and block skip sequences) exceeds 255, the error code
11011322 will be displayed.
Remedy: Decrease the number of mark sequences in sequence data
and then retransmit the program.
• Mark Reading Check
When a program with mark sequences is transmitted and the “Mark
Read Position X” and “Mark Read Position Y” are not found in Proper
data, error code 11011323 will be displayed.
Remedy: Eliminate the mark sequences from sequence data and
retransmit the program.
• Next Device Check
When the device data is checked and the designated number of Next
devices exceeds 30, error code 11011324 will appear.
Remedy: Designate fewer than 30 Next devices.
• Nozzle Size Check
When the nozzle size data in Machine_data (“S_nozzle_size,”
“M_nozzle_size” and “L_nozzle_size”) is checked and even one
nozzle size has not been entered, error code 11011325 will appear.
Remedy: Enter every nozzle diameter size that will be used in that
program into nozzle size data in Machine_data
(“S_nozzle_size,” “M_nozzle_size” and “L_nozzle_size”)
and retransmit the program.
6 – 30Version 2.0