Part 1 7.7 Skipping a Faulty Nozzle A nozzle determined as faulty by nozzle center measurement (due to measurement err or , nozzle bent, abnormal nozzle diameter , etc.) should basically be replaced with a normal nozzle.…

100%1 / 364
Part 1
7.6 Setting the Nozzle Background Disk Diameter
On the FCP IV-3 the background disk diameter can be set which allows a
wider possible range of options related to what type of nozzle can be
affixed in each holder.
The background disk diameter for each nozzle is set in Machine_data in
the program.
Machine_data
42. S_back_light_size 0~50 [mm] = 12
This sets the background disk size (diameter) of the nozzle affixed in
the S holder. Initially this value is set at 12 mm.
43. M_back_light_size 0~50 [mm] = 12
This sets the background disk size (diameter) of the nozzle affixed in
the M holder. Initially this value is set at 12 mm.
44. L_back_light_size 0~50 [mm] = 25
This sets the background disk size (diameter) of the nozzle affixed in
the L holder. Initially this value is set at 25 mm.
1 – 53
FCP IV-3 Operation
Chapter 7 Nozzle Center Measurement
Version 5.0
Part 1
7.7 Skipping a Faulty Nozzle
A nozzle determined as faulty by nozzle center measurement (due to
measurement error, nozzle bent, abnormal nozzle diameter, etc.) should
basically be replaced with a normal nozzle. However it is possible to skip
a faulty nozzle if it cannot be replaced with a normal one because of no
spare nozzles or for other reasons.
To use this function, specify the proper data as follows:
12:Machine Status B 0000 0000 0000 0001
A faulty nozzle skipped with this function will display in red in the skip
nozzle display area. To cancel this function, execute either of the
following methods:
Cancelling by nozzle center measurement
Execute the nozzle center measurement. If measurement result is OK,
the nozzle skip function will be cancelled.
Cancelling by nozzle skip editor
Nozzle skip function can also be cancelled using the nozzle skip
editor. The faulty nozzle must be replaced, otherwise, a nozzle pick-
up or vision processing error will occur if the skip function is
cancelled.