DEUKYX-193-4110_G5S2_VOL4 - 第153页

DEUKYX 2-13 193-41 10 2.2 Management-Informationsliste Code Anzeigebereich A Anzeigebereich B 30416 Operation Requirement ACV server does not pass the authorization. Please retry to connect to server on a screen [UNIT AD…

100%1 / 386
DEUKYX
2-12193-4110
2.2 Management-Informationsliste
Code Anzeigebereich A Anzeigebereich B
18901 Feeder communication
Feeder (Block1) is on communication. Please wait for a second, and then
operate again.
18902 Feeder communication
Feeder (Block2) is on communication. Please wait for a second, and then
operate again.
18a01
Library Feed Pitch
check
Library Feed Pitch differs from Feeder. Please check Library and Feeder.
(Block1)
18a02
Library Feed Pitch
check
Library Feed Pitch differs from Feeder. Please check Library and Feeder.
(Block2)
18b01
Library Tape Width
check
Library Tape Width differs from Feeder. Please check Library and Feeder.
(Block1)
18b02
Library Tape Width
check
Library Tape Width differs from Feeder. Please check Library and Feeder.
(Block2)
19001 Support Pin Please move exchange position of support pin.
19002 Support Pin
There is no available nozzle for backup pin exchange. In the case of a multi
function head, please set a Nozzle to No.1 - No.5 of the stocker, and secure a
Nozzle storage space to No.1 - No.5 of the stocker.
19003 Support Pin
Arranging data in current differs from it of Support Pin of current pattern
program. Please set-up the support pin.
19004 Support Pin
When PCB size 216 mm is exceeded, it is impossible to operate if Support pins
of Lane A remain. Please exchange Lane A, or take out it from machine.
19005 Support Pin
It is impossible to do operation for only Lane B because Support Pins of Lane
A remain. Please exchange Lane A, or take out it from machine.
19006 Support Pin
Operation for Lane A is impossible because Support Pins of Lane A have not
been installed. Please exchange Support pins or store them.
19007 Support Pin
It is impossible to do Operation for only Lane A because Support Pins of Lane
B remain. Please exchange Lane B, or take out it from machine.
19008 Support Pin
Support pins of Lane B remain on the base for Support pins of Lane A, so that
it is impossible to do Conveyor width. Please exchange Support pins or store
them.
19009 Support Pin Arrangement of Support Pins interferes in Conveyor. Please retry to arrange it.
1900A Support Pin
“Vacuum/Blower” of Test Operation Mode is set “Disable”. Execute it after
cancelling Test Operation Mode.
1900B Support Pin
An unsettled component or a Support pin was detected (Head1). Please check
the state of Head, and discard the component.
1900C Support Pin
An unsettled component or a Support pin was detected (Head2). Please check
the state of Head, and discard the component.
1900D Support Pin Please exchange Support pins or store them.
1900E Support Pin
PCB Y size and Conveyor Width in Current Program are not equal. Please
change Current Program.
19101 Single-Tray (Block1)
The connection of Single-Tray differs from Cmpnt Arranging Data. Please
connect Single-Tray to Lane No.25 and No.55 Of Feeder cart.
19102 Single-Tray (Block1) Pallet Error of Single-Tray is detected. Please set Pallet to the inside.
19201 Single-Tray (Block2)
The connection of Single-Tray differs from Cmpnt Arranging Data. Please
connect Single-Tray to Lane No.25 and No.55 Of Feeder cart.
19202 Single-Tray (Block2) Pallet Error of Single-Tray is detected. Please set Pallet to the inside.
3012c Operation Requirement Please change enable mode into disable mode. (serial out mode)
30162 Operation Requirement The pattern cannot be switched
30413 Operation Requirement Specify the order No.
DEUKYX
2-13193-4110
2.2 Management-Informationsliste
Code Anzeigebereich A Anzeigebereich B
30416 Operation Requirement
ACV server does not pass the authorization. Please retry to connect to server
on a screen [UNIT ADJ]-[ACV Set].
3041C Operation Requirement
ACV Check Error. Component ID on the feeder is not same as one specied by
current program.
30420 Operation Requirement
Communications with the ACV server is impossible. After conrming the ACV
server, please retry to perform it. [MAINT]-[UNIT ADJ]-[ACV ADJ].
30421 Operation Requirement
ACV server is out of condition. Check the ACV server. Check HDD capacity,
database breakage, the condition of each module and communication between
severs.
30430 Operation Requirement
Can not detect Feeder cart (Block1). Please set Feeder cart to the inside.
[B0910, B0911]
30431 Operation Requirement
Can not detect Feeder cart (Block2). Please set Feeder cart to the inside.
[B0910, B0911]
30432 Operation Requirement
The connector of the feeder base (Block1) is not connected to the main body,
so that please connect it. [B0916]
30433 Operation Requirement
The connector of the feeder base (Block2) is not connected to the main body,
so that please connect it. [B0916]
30440 Operation Requirement The Safety cover is open. Please close it.
30441 Operation Requirement
It is impossible to do Pass Operation without Cart because func of Traceability
is valid. Please restart after setting Option invalid.
30442 Operation Requirement
It cannot run because a simple Cover locked. First, set Stage ready OFF, then
set Stage ready ON.
30450 Operation Requirement To run is impossible by start protect.
30451 Operation Requirement
Cannot start to run because the output folder on server is disconnected. Please
check output folder setting and the server status of output folder.
30452 Operation Requirement
When “”Lne Operatin System”” is specied besides [LISA], the[Enable (In
Order)] setting cannot be done to “”B.C.D.PpChg-P.P.Chng.Func set””.
30453 Operation Requirement
When “”Lne Operatin System”” is specied besides [LISA], the[Enable (BS)]
setting cannot be done to “”B.C.D.PpChg-P.P.Chng.Func set””.
30454 Operation Requirement
To run is impossible by shortage of components. (Component Remain Stop
Mode: PCB) Please supply the components.
30455 Operation Requirement
To run is impossible by shortage of components. (Component Remain Stop
Mode: Product PCB) Please supply the components.
30456 Operation Requirement
Since the [PCB Finishing Position] data of a Crnt.Prgm is a nish setup
[Sequence], it cannot start (Component Remain Stop Mode). Please set to the
[Output] or the [Input]
30457 Operation Requirement Please start Auto Opn after Comp library data updating.
30458 Operation Requirement The component skip is set up. Please choose other steps.
30459 Operation Requirement
Cannot start to run because the machine event output server is disconnected.
Please check machine event output setting and the server status of output.
30460 Operation Requirement
Moisture deadline of component has passed.
Please replace the component in the moisture deadline.
30461 Operation Requirement
Customer system cooperation: The machine is communicating the non-output
information of the traceability information. Please wait for a second, and then
operate again.
30462 Operation Requirement
AOI feedforward function: The machine is communicating the non-output
information of the Inspection information. Please wait for a second, and then
operate again.
30463 Operation Requirement
Cannot start to run because a LCR check is uncompleted. Please check a
target component in a LCR check screen.
DEUKYX
2-14193-4110
2.2 Management-Informationsliste
Code Anzeigebereich A Anzeigebereich B
30501
Misidentication a type
of Tray
The connected Tray unit (Block1) doesn’t match settings of Device. Please
conrm a type of tray unit, and set it on unit exchange screen.
30502
Misidentication a type
of Tray
The connected Tray unit (Block2) doesn’t match setup of Device. Please
conrm a type of tray unit, and set it on Unit Exchange Screen.
30601
Conrmation of the
position of Noz Stocker
Cannot use Noz stocker from the second to the forth line when full tray is used.
Please set the location of Noz stocker of Device (Block1) on Unit exchange
Screen.
30602
Conrmation of the
position of Noz Stocker
Cannot use Noz stocker from the second to the forth line when full tray is used.
Please set the location of Noz stocker of Device (Block2) on Unit exchange
Screen.
30603
Conrmation of the
position of Noz Stocker
Cannot use Noz stocker from the second to the forth line when full tray is used.
Please conrm the location of Noz stocker of Device (Block1).
30604
Conrmation of the
position of Noz Stocker
Cannot use Noz stocker from the second to the forth line when full tray is used.
Please conrm the location of Noz stocker of Device (Block2).
30701
Conrmation of 2D Bar
code Data
Mark No. of Operating Parameter/2D Bar Code data is specied as All Skip (0).
Please specify proper Mark No.
30801
Detect nozzle coming
off multi-functional
stocker
Machine (Block1) Detected that nozzle has come off the multi-functional
stocker of the 1st line.
30802
Detect nozzle coming
off multi-functional
stocker
Machine (Block1) Detected that nozzle has come off the multi-functional
stocker of the 4th line.
30803
Detect nozzle coming
off multi-functional
stocker
Machine (Block2) Detected that nozzle has come off the multi-functional
stocker of the 1st line.
30804
Detect nozzle coming
off multi-functional
stocker
Machine (Block2) Detected that nozzle has come off the multi-functional
stocker of the 4th line.
30901
Head nozzle dropped
detect
Please lock the main safety cover. Please perform all-zeroing when the main
safety cover has already been locked.
50201
Conrmation of PCB
existence
Remove PCB from the conveyor. Please delete the PCB memory information
on the edit screen if it remains.
50202
Conrmation of PCB
existence
PCB is detected from Input position when Finish mode is set [Output]. Please
PCB from conveyor.
50203
Conrmation of PCB
existence
PCB is detected from Output position when Finish mode is set [Input]. Please
PCB from conveyor.
50204
Conrmation of PCB
existence
PCB is detected from Inlet sensor of input conveyor. Please remove PCB.
50205
Conrmation of PCB
existence
The operation mode of Lane A is set [STOP]. Please remove PCB when not
transferred.
50206
Conrmation of PCB
existence
The operation mode of Lane B is set [STOP]. Please remove PCB when not
transferred.
50207
Conrmation of PCB
existence
There is a possibility that there are 2 sheets of PCB on the input conveyor.
Please remove PCB from Deceleration Sensor, or move it to Stop sensor, or
delete the PCB memory information.
50208
Conrmation of PCB
existence
There is a possibility that there are 2 sheets of PCB on the input conveyor
in Lane A. Please remove PCB from Deceleration Sensor, or move it to Stop
sensor, or delete the PCB memory information.
50209
Conrmation of PCB
existence
There is a possibility that there are 2 sheets of PCB on the output conveyor
in Lane B. Please remove PCB from Deceleration Sensor, or move it to Stop
sensor, or delete the PCB memory information.