DEUKYX-193-4110_G5S2_VOL4 - 第165页
DEUKYX 2-25 193-41 10 3.2 Maschinen-Informationsliste Fehler-Code (HEX) Anzeigebereich A Anzeigebereich B 800617 Alternativer Feeder Alarm Code:E0 - (1) Damaged cover tape/ (2) Cover tape jammed in the storage/ (3) Splic…

DEUKYX
2-24193-4110
3.2 Maschinen-Informationsliste
3.2 Maschinen-Informationsliste
Nachfolgend nden Sie eine Liste der Maschinen-Informationen sortiert nach
Fehlercodes.
Fehler-Code
(HEX)
Anzeigebereich A Anzeigebereich B
800301
Warnung: Decreasing
of Comp. Hdlg. Rate
(For Nozzle.)
Nozzle message rate :
800302
Warnung: Decreasing
of Comp. Hdlg. Rate
(For Nozzle.)
The rate of nozzle adsorption fell. A cycle stop is carried out.
800401
Warnung: Decreasing
of Comp. Hdlg. Rate
(For Fdr.)
Feeder message rate :
800402
Warning: Decreasing
of Comp. Hdlg. Rate
(For Fdr.)
The rate of nozzle adsorption fell. A cycle stop is carried out.
800505
Alternated Tray
Magazine Axis
Shortage of component
800601 Alternativer Feeder Shortage of component
800602 Alternativer Feeder Splice waiting
800603 Alternativer Feeder Komp. Vertical(Sensor)
800604 Alternativer Feeder Komp. Thickness(Sensor)
800605 Alternativer Feeder Komp. Missing (Sensor)
800606 Alternativer Feeder Komp. Erkenn. Error (recog.)
800607 Alternativer Feeder Komp. Missing (Recog)
800608 Alternativer Feeder Coplanarity Check Error
800609 Alternativer Feeder The feeder at the alternation destination is invalid. Please set it effectively.
80.060a Alternativer Feeder Feeder unloading
80060b Alternated Feeder Returned to the priority feeder
80060c Alternated Feeder It was alternated.
80060d Alternated Feeder Feeder Alarm
80060e Alternated Feeder Alarm Code:A0 - Internal Parameter Error (Breakdown of Control P.C.B.)
80060f Alternativer Feeder
Alarm Code:A1 - Over Current Error (Foreign substances in the tape feeding
drive section)
800610 Alternativer Feeder
Alarm Code:A4 - Main Circuit Power Supply Error (Please check the power
supply voltage.) (G04)
800611 Alternativer Feeder Alarm Code:A5 - Fault Speed Error (Tape catching)
800612 Alternativer Feeder
Alarm Code:A7 - Fault Load Error (Tape twisting, Catching foreign
substances)
800613 Alternativer Feeder
Alarm Code:A8 - Encoder Error (Breaking wire, Breakdown of control P.C.B.
and Defective servo motor)
800614 Alternativer Feeder Alarm Code:Ab - System Error
800615 Alternativer Feeder Alarm Code:Ac - Reckless Run Detection Error
800616 Alternativer Feeder Alarm Code:Ad - Excessive deviation in position

DEUKYX
2-25193-4110
3.2 Maschinen-Informationsliste
Fehler-Code
(HEX)
Anzeigebereich A Anzeigebereich B
800617 Alternativer Feeder
Alarm Code:E0 - (1) Damaged cover tape/ (2) Cover tape jammed in the
storage/ (3) Splicing section peeling off
800618 Alternativer Feeder Alarm Code:E1 - Cover tape peeling off error (Get caught up)
800619 Alternativer Feeder
Alarm Code:E2 - Origin Position Checking Error (Excessively out of the
origin during servo ON)
80.061a Alternativer Feeder
Alarm Code:E3 - (1)No supplied history/ (2)Dirty splicing detection sensor
(dust adhesion)
80061b Alternated Feeder
Alarm Code:E4 - Positioning Completion Timeout (Foreign substances in the
sprocket wheel)
80061c Alternated Feeder Alarm Code:E5 - Redundant Order Error (A feeding error may occur.)
80061d Alternated Feeder Alarm Code:E6 - Lane Change Timeout Error
80061e Alternated Feeder Alarm Code:E7 - Servo ON Timeout
80061f Alternated Feeder Obverse/Reverse inspection detect (Sensor)
800801
Start Auto Recovery
Mode
Shortage of component
800802
Start Auto Recovery
Mode
Splice waiting
800803
Start Auto Recovery
Mode
Comp. Vertical (Sensor)
800804
Start Auto Recovery
Mode
Comp. Thickness (Sensor)
800805
Start Auto Recovery
Mode
Comp. Missing (Sensor)
800806
Start Auto Recovery
Mode
Comp. Recog. Error (recog.)
800807
Start Auto Recovery
Mode
Comp. Missing (Recog)
800808
Start Auto Recovery
Mode
Coplanarity Check Error
800809
Start Auto Recovery
Mode
Feeder Alarm
80080a
Start Auto Recovery
Mode
Feeder unloading
80080b
Start Auto Recovery
Mode
Device Op is stopped because Feeder is not loaded.
80080c
Start Auto Recovery
Mode
Etc
80080d
Start Auto Recovery
Mode
Obverse/Reverse inspection error (Sensor)
80080e
Start Auto Recovery
Mode
SL feeder loading operation
80080f
Start Auto Recovery
Mode
Following tape of non-registration was detected. Please operate the
component supply.
800810
Start Auto Recovery
Mode
Following tape was detected. Please verify the component.
800811
Start Auto Recovery
Mode
Placement cycles of both heads are postponed together for SL feeder
loading.
800902
Alarm for Shortage of
Comp.
Few components to feed.

DEUKYX
2-26193-4110
3.2 Maschinen-Informationsliste
Fehler-Code
(HEX)
Anzeigebereich A Anzeigebereich B
801101
Nozzle diameter
conrmation
The disagreement of the nozzle diameter was detected with the side view
camera. There is a possibility of the side view camera dirt and the nozzle
dirt, please conrm whether a different nozzle has adhered.
801b01 Lightning Surge alarm Lightning Surge Protector works; Q204.
801b02 Lightning Surge alarm Lightning Surge Protector works; Q204. Running continue.
801b03 Lightning Surge alarm Protective Fuse error of lightning Surge Protector. Exchange the fuse.
801c05 Information Warm start mode was canceled.
801c06 Information The machine stopped by the automatic stop function.
801c07 Information The machine will be stopped by start protect.
801c08 Information
The machine will be stopped by Component Remain Stop Mode. (CompRem
is less than the number of the whole PCB use)
801c09 Information
The machine will be stopped by Component Remain Stop Mode. (CompRem
is less than the number of the whole Product PCB use)
801c0a Information A stop request by Component Remain Stop Mode was canceled.
801c0b Information Trash box ll up.
801c0c Information Trash box of Cart#1 is ll up.
801c0d Information Trash box of Cart#2 is ll up.
801c0f Information Delay has occurred in the communications processing inside machine.
801c10 Information
The machine operation was stopped by a function of the P.C.B. counter stop
mode.
801c11 Information
The component skip is set up. It is not placed with the components by which
a skip setup was carried out.
801c12 Information
The recognition image saved is over 200 MB. Please delete an unnecessary
le.
801c13 Information
Since the database of the component library was damaged, restoration
processing was performed.
801c14 Information
Since the database of the test library was damaged, restoration processing
was performed.
801c15 Information
The recognition image saved is over 400 MB. Please delete an unnecessary
le.
801c16 Information The appointed PCB was skipped.
801c17 Information The program change was completed.
801c18 Information
The machine implemented parts picked up it by an abnormal stop. (Detecting
pickup miss Cmpnt)
801c1d Information
Memories are insufcient. Since there is a possibility that an operation
screen may hang-up, please reboot the machine.
801c1e Information The program change was completed.
802001 Alarm for Splicing
The feeder is running short of the component to feed. Please prepare for
Splicing, and remove the cover tape from the storage section.
802101
Feeder Maintenance
alarm
The total number of feeder's shots reached a previous notice setting
number.
802102
Feeder Maintenance
alarm
The feeder adsorption rate decreased and exceeded the previous notice
setting number.
802103
Feeder Maintenance
alarm
The total number of feeder's shots reached a previous notice setting
number.
802104
Feeder Maintenance
alarm
The feeder adsorption rate decreased and exceeded the previous notice
setting number.