DEUKYX 3-21 193-41 10 3.2 Daten 3.2 Daten Error ID Fehlername, Beschreibung, Ursache und Wiederherstellung 410301 Pattern Program Error Steps in converted pattern program is more ----- 410302 Pattern Program Error There …

DEUKYX
3-20193-4110
3.1 Sicherheitsgerät
Error ID Fehlername, Beschreibung, Ursache und Wiederherstellung
407101 Detecting Head2 nozzle descending
Invalid detection of head2 nozzle descending
Fahren Sie das System in die Nullposition.
407201 Pass Line detect(Head1)
Invalid detection of Pass line(Head1)
Fahren Sie das System in die Nullposition.
407301 Pass Line detect(Head2)
Invalid detection of Pass line(Head2)
Fahren Sie das System in die Nullposition.
408001 Nozzle interference detect adjacent to multi-functional head
Emergency stopped a head because a nozzle adjacent to it interfered.
Fahren Sie das System in die Nullposition.
408301 Feeder opening sensor (Block 1) detect
The feeder opening sensor (Block 1) was shaded.
Entfernen Sie den Fremdkörper, der den Feeder-Sensor (Block 1) verdeckt und
starten Sie neu.
408401 Feeder opening sensor (Block 2) detect
The feeder opening sensor (Block 2) was shaded.
Entfernen Sie den Fremdkörper, der den Feeder-Sensor (Block 2) verdeckt und
starten Sie neu.

DEUKYX
3-21193-4110
3.2 Daten
3.2 Daten
Error ID Fehlername, Beschreibung, Ursache und Wiederherstellung
410301 Pattern Program Error
Steps in converted pattern program is more
-----
410302 Pattern Program Error
There are Errors in converted pattern program(PCB recog steps Error.)
-----
410303 Pattern Program Error
The converted pattern program is not exist, the data is damaged.
-----
410304 Pattern Program Error
The error is found in the adsorption nozzle number of the conversion pattern program.
-----
410305 Pattern Program Error
The error is found in the order of adsorption of the conversion system pattern program.
-----
410306 Pattern Program Error
The error is found in the nozzle candidate number of the conversion pattern program.
-----
410307 Pattern Program Error
The error is found in the adsorption lane number of the conversion pattern program.
-----
410401 Data Error
The components library does not exist. Or, data is in loss.
-----
410402 Data Error
Data relating to nozzle does not exist. Or, data is in loss.
-----
410701 Program Error
It was a error setting of the sequence data.
-----
410801 2D bar code data Error
It was a error setting of the sequence data.
-----
410802 2D bar code data Error
Failed in start-up Sequence
-----
410803 2D bar code data Error
The error is found in coordinates calculation.
-----
410804 2D bar code data Error
Could not continue for Errors.
-----

DEUKYX
3-22193-4110
3.3 Conveyor
3.3 Conveyor
Error ID Fehlername, Beschreibung, Ursache und Wiederherstellung
420001 Error in Transfer section
-----
420002 Error in Transfer section
Transfer operation was not completed within a specied time.
-----
420003 Error in Transfer section
Positioning has errors.
-----
420004 Error in Transfer section
Input conveyor has errors.
-----
420005 Error in Transfer section
Positioning conveyor has errors.
-----
420006 Error in Transfer section
Output conveyor has errors.
-----
420007 Error in Transfer section
Interlock has been detected.
-----
420008 Error in Transfer section
Transfer was stopped.
-----
420101 Backup(L) Error.
The movement of Backup (L) Axis was not completed within predetermined time.
Die Backup-Achse lässt sich nicht heben oder senken.
Dies kann am Motor, dem Sensor oder der Verkabelung liegen.
Prüfen Sie auf dem Maschinen-Bildschirm Motor und Sensor.
420102 Backup(L) Error.
Driver Alarm on Backup (L) Axis
Setzen Sie den ALarm im Subsystem-Fehlerzähler zurück.
420103 Backup(L) Error.
Error in calculating data of Backup (L) Axis
Prüfen Sie folgende Daten:
1. Maschinenoffset/Abstützstifte (heben/senken)
2. Bestückungsprogramm/LP-Informationen/LP-Größe/Dicke
3. Steuerung/Gemeinsam/Dicke Vorbestückte Bauteile/LP-Unterseite
420104 Backup(L) Error.
Time-over of zeroing of Backup (L) Axis
Prüfen Sie auf Schmutz, Fehler, Verkabelung des Sensor Ist der Sensor OK,
kann es an der Verkabelung des Motors liegen/Einzelfehler.