DEUKYX-193-4110_G5S2_VOL4 - 第308页

DEUKYX 3-130 193-41 10 3.1 1 Handhabungsfehler 3.1 1 Handhabungsfehler Error ID Fehlername, Beschreibung, Ursache und Wiederherstellung 500101 Comp. Missing (Sensor) Comp. Missing (Sensor) Prüfen Sie, ob das Bauteile auf…

100%1 / 386
DEUKYX
3-129193-4110
3.10 Andere Fehler
Error ID Fehlername, Beschreibung, Ursache und Wiederherstellung
4b7201 BCD PP Change error
Disconnected server for BCD PP change reference folder. Please checking
connection status.
-----
4b7202 BCD PP Change error
Could not output pattern program list le to server for BCD PP change reference
folder. Please checking connection status and le of shared folder.
-----
4b7203 BCD PP Change error
Could not delete pattern program list le on server for BCD PP change reference
folder. Please checking connection status and le of shared folder.
-----
4b7204 BCD PP Change error
The PP info le is not found. Please register the PP info le with the GCM server.
-----
4b7205 BCD PP Change error
The format is abnormal of the PP info le (Placement OK/NG data is abnormal).
-----
4b7206 BCD PP Change error
The format is abnormal of the PP info le (Placement pattern ID name is
abnormal).
-----
4b7207 BCD PP Change error
The format is abnormal of the PP info le (Placement OK/NG data:NG).
-----
DEUKYX
3-130193-4110
3.11 Handhabungsfehler
3.11 Handhabungsfehler
Error ID Fehlername, Beschreibung, Ursache und Wiederherstellung
500101 Comp. Missing (Sensor)
Comp. Missing (Sensor)
Prüfen Sie, ob das Bauteile auf den Feeder gefallen sind.
500301 Comp. Missing (Sensor)
Comp. Missing (Sensor)
Prüfen Sie, ob das Bauteile auf den Feeder gefallen sind. Wird ein gefederter
Aufnehmer verwendet, prüfen Sie die Funktion der Feder.
500401 Comp. Recog Error
Comp. Recog Error
-----
500501 Shortage of Component
Shortage of Component
-----
500502 Feeder Reload Stop
Feeder Reload Stop (Splicing)
-----
500c01 Comp. Vertical(Sensor)
Comp. Vertical(Sensor)
-----
500f01 Comp. Thickness(Sensor)
Comp. Thickness(Sensor)
-----
501001 Opt. Error(Feeder)
Feeder falls out
Feeder ausgefallen. Prüfen Sie, ob evtl. auch der Aufnehmer beschädigt wurde.
501101 Obverse/Reverse inspection error(Sensor)
Obverse/Reverse inspection error(Sensor)
-----
DEUKYX
3-131193-4110
3.12 Fehler im Automatikbetrieb
3.12 Fehler im Automatikbetrieb
Error ID Fehlername, Beschreibung, Ursache und Wiederherstellung
510a01 Feeder Pocket recog Error
Abnormality occurred in process of recognizing Feeder Pocket.
-----
510b01 Auto Run Error
Master bad mark detection is abnormal.
-----
510b02 Auto Run Error
Bad mark detection is abnormal.
-----
510e01 Nozzle air blow Error(Head1)
Because abnormality had occurred while processing the nozzle air blow,
processing was interrupted.
-----
510e02 Nozzle air blow Error(Head1)
Because abnormality had occurred while processing the nozzle air blow,
processing was interrupted.
-----
510e03 Nozzle air blow Error(Head1)
Because abnormality had occurred while processing the nozzle air blow,
processing was interrupted.
-----
510f01 Nozzle air blow Error(Head2)
Because abnormality had occurred while processing the nozzle air blow,
processing was interrupted.
-----
510f02 Nozzle air blow Error(Head2)
Because abnormality had occurred while processing the nozzle air blow,
processing was interrupted.
-----
510f03 Nozzle air blow Error(Head2)
Because abnormality had occurred while processing the nozzle air blow,
processing was interrupted.
-----
511001 Head1 Preparation Error
Because abnormality had occurred while processing the preparation, processing
was interrupted.
-----
511002 Head1 Preparation Error
Because abnormality had occurred while processing the preparation, processing
was interrupted.
-----