DEUKYX-193-4110_G5S2_VOL4 - 第316页

DEUKYX 3-138 193-41 10 3.13 Autom. T eaching Error ID Fehlername, Beschreibung, Ursache und Wiederherstellung 600401 Head Rotate center offset teach Can not recognize Glass Jig Prüfen Sie, ob sich der Glasrahmen an der r…

100%1 / 386
DEUKYX
3-137193-4110
3.13 Autom. Teaching
Error ID Fehlername, Beschreibung, Ursache und Wiederherstellung
600306 Head Rotate Theta Axis offset
Error during rotation of DD-axis
-----
600307 Head Rotate Theta Axis offset
Error when HL-axis and NL-axis began zeroing
-----
600308 Head Rotate Theta Axis offset
Error while HL-axis and NL-axis on zeroing movement
-----
600309 Head Rotate Theta Axis offset
Error of Data set for XY Beam.
-----
60030a Head Rotate Theta Axis offset
Error of moving for XY Beam.
-----
60030b Head Rotate Theta Axis offset
Time-out in XY Beam movement
-----
60030c Head Rotate Theta Axis offset
Time-out of communication with recognition.
-----
60030d Head Rotate Theta Axis offset
Error when L-axis began zeroing
-----
60030e Head Rotate Theta Axis offset
Error of L-axis on zeroing
-----
60030f Head Rotate Theta Axis offset
Error when L-axis began to drop
-----
600310 Head Rotate Theta Axis offset
Error in L-axis dropped
-----
600311 Head Rotate Theta Axis offset
Time-out of the movement of L-axis, Z-axis
-----
600312 Head Rotate Theta Axis offset
Error when Z-axis began to move
-----
600313 Head Rotate Theta Axis offset
Error while Z-axis is moving
-----
600314 Head Rotate Theta Axis offset
Error in Head rotate Theta axis Offset.
-----
DEUKYX
3-138193-4110
3.13 Autom. Teaching
Error ID Fehlername, Beschreibung, Ursache und Wiederherstellung
600401 Head Rotate center offset teach
Can not recognize Glass Jig
Prüfen Sie, ob sich der Glasrahmen an der richtigen Position bendet (Es besteht
die Möglichkeit, dass sich der Aufnehmer nicht im Kopf bendet oder kein Vakuum
anliegt.)
600402 Head Rotate center offset teach
Error of Recognition Command response.
-----
600403 Head Rotate center offset teach
Error of coordinates calculation.
-----
600404 Head Rotate center offset teach
Error when Jig pickup began
-----
600405 Head Rotate center offset teach
Error in the movement of Jig pickup
-----
600406 Head Rotate center offset teach
Error when Jig store began
-----
600407 Head Rotate center offset teach
Error in the movement of Jig store
-----
600408 Head Rotate center offset teach
Error when HL-axis and NL-axis began zeroing.
-----
600409 Head Rotate center offset teach
Error while HL-axis and NL-axis are on zeroing
-----
60040a Head Rotate center offset teach
Error when DD-axis began to rotate
-----
60040b Head Rotate center offset teach
Error while DD-axis is rotating
-----
60040c Head Rotate center offset teach
Error of Data set for XY Beam.
-----
60040d Head Rotate center offset teach
Error of moving for XY Beam.
-----
60040e Head Rotate center offset teach
Time-out in XY Beam
-----
60040f Head Rotate center offset teach
Time-out of communication with recognition
-----
DEUKYX
3-139193-4110
3.13 Autom. Teaching
Error ID Fehlername, Beschreibung, Ursache und Wiederherstellung
600410 Head Rotate center offset teach
Error when L-axis began zeroing
-----
600411 Head Rotate center offset teach
Error while L-axis is on zeroing
-----
600412 Head Rotate center offset teach
Error when Z-axis began to rotate
-----
600413 Head Rotate center offset teach
Error while Z-axis is rotating
-----
600414 Head Rotate center offset teach
Error when L-axis began to drop
-----
600415 Head Rotate center offset teach
Error when L-axis is dropping
-----
600416 Head Rotate center offset teach
Error in Teaching Head Rotate center offset.
-----
600501 Reference mark position teach
Could not recognize Glass Jig in CTR Fly Recognition.
Prüfen Sie, ob sich der Glasrahmen an der richtigen Position bendet (Es besteht
die Möglichkeit, dass sich der Aufnehmer nicht im Kopf bendet oder kein Vakuum
anliegt.)
600502 Reference mark position teach
Error of Recognition Command response in case of CTR Fly Recognition
-----
600503 Reference mark position teach
Could not recognize Standard Mark
1. Reinigen Sie den Markenbereich.
2. Prüfen Sie die Beleuchtung.
600504 Reference mark position teach
Error of Recognition Command response in case of Standard Mark Recognition
-----
600505 Reference mark position teach
Error of coordinates calculation of CTR Fly Recognition
-----
600506 Reference mark position teach
Error when Jig pickup of CTR Fly Recognition began
-----
600507 Reference mark position teach
Error of the movement of Jig pickup of CTP Fly Recognition
-----
600508 Reference mark position teach
Error when Jig store of CTR Fly Recognition began
-----