DEUKYX-193-4110_G5S2_VOL4 - 第334页
DEUKYX 3-156 193-41 10 3.13 Autom. T eaching Error ID Error Name, Description, Cause, and Remedy 604301 Chute(For Head exchange) teaching Height Error is detected before starting Detection on Side view camera.(There is a…

DEUKYX
3-155193-4110
3.13 Autom. Teaching
Error ID Fehlername, Beschreibung, Ursache und Wiederherstellung
60420b Chute(For adjustment when shipping up) Teaching Height
Time-out of starting NL-axis movement
-----
60420c Chute(For adjustment when shipping up) Teaching Height
Time-out of nishing HL/NL-axis movement
-----
60420d Chute(For adjustment when shipping up) Teaching Height
Failed in measuring real time of side view camera.
-----
60420e Chute(For adjustment when shipping up) Teaching Height
Error in measuring Side view camera
-----
60420f Chute(For adjustment when shipping up) Teaching Height
Flange of Nozzle is not detected within the predetermine range.(Not E/NR)
Vermessen Sie, nachdem die Kopfrotation auf der Winkelachse ermittelt wurde,
die Höhe neu.
604210 Chute(For adjustment when shipping up) Teaching Height
Flange of Nozzle is not detected within the predetermine range.(E/NR)
Vermessen Sie, nachdem die Kopfrotation auf der Winkelachse ermittelt wurde,
die Höhe neu.
604211 Chute(For adjustment when shipping up) Teaching Height
The height of Flange of Nozzle is not changed.(Nozzle pressed is not detected.)
-----
604212 Chute(For adjustment when shipping up) Teaching Height
Program Error
-----
604213 Chute(For adjustment when shipping up) Teaching Height
Offset is 1mm less than the set value.
-----
604214 Chute(For adjustment when shipping up) Teaching Height
Offset is 1mm more than the set value.
-----
604215 Chute(For adjustment when shipping up) Teaching Height
The value of Flowmeter is higher than 5.0V.
-----
604216 Chute(For adjustment when shipping up) Teaching Height
The value of Flowmeter is lower than 4.7V.
-----
604217 Chute(For adjustment when shipping up) Teaching Height
There is no measured data of Noz 1. It is necessary to measure Noz1 rst.
-----
604218 Chute(For adjustment when shipping up) Teaching Height
Cannot measure it for XY-coord is not dened.
-----
604219 Chute(For adjustment when shipping up) Teaching Height
Error in Flowing Quantity
-----

DEUKYX
3-156193-4110
3.13 Autom. Teaching
Error ID Error Name, Description, Cause, and Remedy
604301 Chute(For Head exchange) teaching Height
Error is detected before starting Detection on Side view camera.(There is a
possibility that Side view camera is broken, or Odd Noz is placed.)
-----
604302 Chute(For Head exchange) teaching Height
Time-out of [OFF] signal of Side view camera
-----
604303 Chute(For Head exchange) teaching Height
Error in DD-axis
-----
604304 Chute(For Head exchange) teaching Height
Error in NS-axis
-----
604305 Chute(For Head exchange) teaching Height
Error in DD/NS-axis
-----
604306 Chute(For Head exchange) teaching Height
Time-out of DD/NS-axis
-----
604307 Chute(For Head exchange) teaching Height
Error in calculating drive wave of HL-axis
-----
604308 Chute(For Head exchange) teaching Height
Error in calculating drive wave of NL-axis
-----
604309 Chute(For Head exchange) teaching Height
Time-out of starting HL/NL-axis movement
-----
60430a Chute(For Head exchange) teaching Height
Time-out of starting HL-axis movement
-----
60430b Chute(For Head exchange) teaching Height
Time-out of starting NL-axis movement
-----
60430c Chute(For Head exchange) teaching Height
Time-out of nishing HL/NL-axis movement
-----
60430d Chute(For Head exchange) teaching Height
Failed in measuring real time of side view camera.
-----
60430e Chute(For Head exchange) teaching Height
Error in measuring Side view camera
-----
60430f Chute(For Head exchange) teaching Height
Flange of Nozzle is not detected within the predetermine range.(Not E/NR)
Vermessen Sie, nachdem die Kopfrotation auf der Winkelachse ermittelt wurde,
die Höhe neu.

DEUKYX
3-157193-4110
3.13 Autom. Teaching
Error ID Error Name, Description, Cause, and Remedy
604310 Chute(For Head exchange) teaching Height
Flange of Nozzle is not detected within the predetermine range.(E/NR)
Vermessen Sie, nachdem die Kopfrotation auf der Winkelachse ermittelt wurde,
die Höhe neu.
604311 Chute(For Head exchange) teaching Height
The height of Flange of Nozzle is not changed.(Nozzle pressed is not detected.)
-----
604312 Chute(For Head exchange) teaching Height
Program Error
-----
604313 Chute(For Head exchange) teaching Height
Offset is 1mm less than the set value.
-----
604314 Chute(For Head exchange) teaching Height
Offset is 1mm more than the set value.
-----
604315 Chute(For Head exchange) teaching Height
The value of Flowmeter is higher than 5.0V.
-----
604316 Chute(For Head exchange) teaching Height
The value of Flowmeter is lower than 4.7V.
-----
604317 Chute(For Head exchange) teaching Height
There is no measured data of Noz 1. It is necessary to measure Noz1 rst.
-----
604318 Chute(For Head exchange) teaching Height
Cannot measure it for XY-coord is not dened.
-----
604319 Chute(For Head exchange) teaching Height
Error in Flowing Quantity
-----
604401 Teaching Height of Stocker Master
Error is detected before starting Detection on Side view camera.(There is a
possibility that Side view camera is broken, or Odd Noz is placed.)
-----
604402 Teaching Height of Stocker Master
Time-out of [OFF] signal of Side view camera
-----
604403 Teaching Height of Stocker Master
Error in DD-axis
-----
604404 Teaching Height of Stocker Master
Error in NS-axis
-----
604405 Teaching Height of Stocker Master
Error in DD/NS-axis
-----