DEUKYX 3-161 193-41 10 3.13 Autom. T eaching Error ID Fehlername, Beschreibung, Ursache und Wiederherstellung 604601 T eaching Height of Glass Jig Error is detected before starting Detection on Side view camera.(There is…

100%1 / 386
DEUKYX
3-160193-4110
3.13 Autom. Teaching
Error ID Error Name, Description, Cause, and Remedy
60450b Teaching Pickup-Height
Time-out of starting NL-axis movement
-----
60450c Teaching Pickup-Height
Time-out of nishing HL/NL-axis movement
-----
60450d Teaching Pickup-Height
Failed in measuring real time of side view camera.
-----
60450e Teaching Pickup-Height
Error in measuring Side view camera
-----
60450f Teaching Pickup-Height
Flange of Nozzle is not detected within the predetermine range.(Not E/NR)
Vermessen Sie, nachdem die Kopfrotation auf der Winkelachse ermittelt wurde,
die Höhe neu.
604510 Teaching Pickup-Height
Flange of Nozzle is not detected within the predetermine range.(E/NR)
Vermessen Sie, nachdem die Kopfrotation auf der Winkelachse ermittelt wurde,
die Höhe neu.
604511 Teaching Pickup-Height
The height of Flange of Nozzle is not changed.(Nozzle pressed is not detected.)
-----
604512 Teaching Pickup-Height
Program Error
-----
604513 Teaching Pickup-Height
Offset is 1mm less than the set value.
-----
604514 Teaching Pickup-Height
Offset is 1mm more than the set value.
-----
604515 Teaching Pickup-Height
The value of Flowmeter is higher than 5.0V.
-----
604516 Teaching Pickup-Height
The value of Flowmeter is lower than 4.7V.
-----
604517 Teaching Pickup-Height
There is no measured data of Noz 1. It is necessary to measure Noz1 rst.
-----
604518 Teaching Pickup-Height
Cannot measure it for XY-coord is not dened.
-----
604519 Teaching Pickup-Height
Error in Flowing Quantity
-----
DEUKYX
3-161193-4110
3.13 Autom. Teaching
Error ID Fehlername, Beschreibung, Ursache und Wiederherstellung
604601 Teaching Height of Glass Jig
Error is detected before starting Detection on Side view camera.(There is a possi-
bility that Side view camera is broken, or Odd Noz is placed.)
-----
604602 Teaching Height of Glass Jig
Time-out of [OFF] signal of Side view camera
-----
604603 Teaching Height of Glass Jig
Error in DD-axis
-----
604604 Teaching Height of Glass Jig
Error in NS-axis
-----
604605 Teaching Height of Glass Jig
Error in DD/NS-axis
-----
604606 Teaching Height of Glass Jig
Time-out of DD/NS-axis
-----
604607 Teaching Height of Glass Jig
Error in calculating drive wave of HL-axis
-----
604608 Teaching Height of Glass Jig
Error in calculating drive wave of NL-axis
-----
604609 Teaching Height of Glass Jig
Time-out of starting HL/NL-axis movement
-----
60460a Teaching Height of Glass Jig
Time-out of starting HL-axis movement
-----
60460b Teaching Height of Glass Jig
Time-out of starting NL-axis movement
-----
60460c Teaching Height of Glass Jig
Time-out of nishing HL/NL-axis movement
-----
60460d Teaching Height of Glass Jig
Failed in measuring real time of side view camera.
-----
60460e Teaching Height of Glass Jig
Error in measuring Side view camera
-----
60460f Teaching Height of Glass Jig
Flange of Nozzle is not detected within the predetermine range.(Not E/NR)
Vermessen Sie, nachdem die Kopfrotation auf der Winkelachse ermittelt wurde,
die Höhe neu.
DEUKYX
3-162193-4110
3.13 Autom. Teaching
Error ID Fehlername, Beschreibung, Ursache und Wiederherstellung
604610 Teaching Height of Glass Jig
Flange of Nozzle is not detected within the predetermine range.(E/NR)
Vermessen Sie, nachdem die Kopfrotation auf der Winkelachse ermittelt wurde,
die Höhe neu.
604611 Teaching Height of Glass Jig
The height of Flange of Nozzle is not changed.(Nozzle pressed is not detected.)
-----
604612 Teaching Height of Glass Jig
Program Error
-----
604613 Teaching Height of Glass Jig
Offset is 1mm less than the set value.
-----
604614 Teaching Height of Glass Jig
Offset is 1mm more than the set value.
-----
604615 Teaching Height of Glass Jig
The value of Flowmeter is higher than 5.0V.
-----
604616 Teaching Height of Glass Jig
The value of Flowmeter is lower than 4.7V.
-----
604617 Teaching Height of Glass Jig
There is no measured data of Noz 1. It is necessary to measure Noz1 rst.
-----
604618 Teaching Height of Glass Jig
Cannot measure it for XY-coord is not dened.
-----
604619 Teaching Height of Glass Jig
Error in Flowing Quantity
-----
604701 Teaching Height of Traverse Chute
Error is detected before starting Detection on Side view camera.(There is a possi-
bility that Side view camera is broken, or Odd Noz is placed.)
-----
604702 Teaching Height of Traverse Chute
Time-out of [OFF] signal of Side view camera
-----
604703 Teaching Height of Traverse Chute
Error in DD-axis
-----
604704 Teaching Height of Traverse Chute
Error in NS-axis
-----
604705 Teaching Height of Traverse Chute
Error in DD/NS-axis
-----